BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 12735430)

  • 1. A comparison of abdominal ECG and Doppler ultrasound for fetal heart rate detection.
    Ibrahimy MI; Mohd Ali MA; Zahedi E; Tsuruoka S
    Front Med Biol Eng; 2002; 11(4):307-22. PubMed ID: 12735430
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time signal processing for fetal heart rate monitoring.
    Ibrahimy MI; Ahmed F; Mohd Ali MA; Zahedi E
    IEEE Trans Biomed Eng; 2003 Feb; 50(2):258-62. PubMed ID: 12665042
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fetal electrocardiography: feasibility of long-term fetal heart rate recordings.
    Graatsma EM; Jacod BC; van Egmond LA; Mulder EJ; Visser GH
    BJOG; 2009 Jan; 116(2):334-7; discussion 337-8. PubMed ID: 19076966
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes.
    Cohen WR; Ommani S; Hassan S; Mirza FG; Solomon M; Brown R; Schifrin BS; Himsworth JM; Hayes-Gill BR
    Acta Obstet Gynecol Scand; 2012 Nov; 91(11):1306-13. PubMed ID: 22924738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fetal and maternal heart rate confusion during intra-partum monitoring: comparison of trans-abdominal fetal electrocardiogram and Doppler telemetry.
    Stampalija T; Signaroldi M; Mastroianni C; Rosti E; Signorelli V; Casati D; Ferrazzi EM
    J Matern Fetal Neonatal Med; 2012 Aug; 25(8):1517-20. PubMed ID: 22070793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Implementation of a real-time algorithm for maternal and fetal heart rate monitoring in a digital signal controller platform.
    Arias-Ortega R; Gaitán-González MJ; Yáñez-Suarez O
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():2354-7. PubMed ID: 21097225
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A study of a fetal heart rate calculation system based on R-R interval.
    Zhang Y; Zhang S; Yang L; Yang Y; Li X; Hao D; Xu M; Shao J
    Technol Health Care; 2020; 28(S1):187-195. PubMed ID: 32364151
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Power spectrum analysis of fetal heart rate variability using the abdominal maternal electrocardiogram.
    Abboud S; Sadeh D
    J Biomed Eng; 1990 Mar; 12(2):161-4. PubMed ID: 2319767
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heart rate detection in low amplitude non-invasive fetal ECG recordings.
    Peters C; Vullings R; Bergmans J; Oei G; Wijn P
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6092-4. PubMed ID: 17946740
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram.
    Piéri JF; Crowe JA; Hayes-Gill BR; Spencer CJ; Bhogal K; James DK
    Med Biol Eng Comput; 2001 Jan; 39(1):118-25. PubMed ID: 11214263
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Separation and Analysis of Fetal-ECG Signals From Compressed Sensed Abdominal ECG Recordings.
    Da Poian G; Bernardini R; Rinaldo R
    IEEE Trans Biomed Eng; 2016 Jun; 63(6):1269-79. PubMed ID: 26513775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low-complexity R-peak detection for ambulatory fetal monitoring.
    Rooijakkers MJ; Rabotti C; Oei SG; Mischi M
    Physiol Meas; 2012 Jul; 33(7):1135-50. PubMed ID: 22735075
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fetal heart rate detection in multivariate abdominal ECG recordings using non-linear analysis.
    Karvounis EC; Tsipouras MG; Fotiadis DI
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2141-4. PubMed ID: 19163120
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic segmentation and linear prediction for maternal ECG removal in antenatal abdominal recordings.
    Vullings R; Peters CH; Sluijter RJ; Mischi M; Oei SG; Bergmans JW
    Physiol Meas; 2009 Mar; 30(3):291-307. PubMed ID: 19223679
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An instrument using parallel filtering of acoustic signals to record fetal heart rate.
    Kovács F; Török M
    Biomed Instrum Technol; 1995; 29(3):213-9. PubMed ID: 7613568
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integration of multivariate empirical mode decomposition and independent component analysis for fetal ECG separation from abdominal signals.
    Thanaraj P; Roshini M; Balasubramanian P
    Technol Health Care; 2016 Nov; 24(6):783-794. PubMed ID: 27315149
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram.
    Jezewski J; Matonia A; Kupka T; Roj D; Czabanski R
    Biomed Tech (Berl); 2012 Oct; 57(5):383-94. PubMed ID: 25854665
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel algorithm based on ensemble empirical mode decomposition for non-invasive fetal ECG extraction.
    Barnova K; Martinek R; Jaros R; Kahankova R; Matonia A; Jezewski M; Czabanski R; Horoba K; Jezewski J
    PLoS One; 2021; 16(8):e0256154. PubMed ID: 34388227
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Maternal and fetal heart rate extraction from abdominal recordings using multi-scale principal components analysis.
    Karvounis EC; Fotiadis DI
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():6508-11. PubMed ID: 18003516
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-lead noninvasive fetal ECG extraction by means of combining clustering and principal components analysis.
    Zhang Y; Yu S
    Med Biol Eng Comput; 2020 Feb; 58(2):419-432. PubMed ID: 31858419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.