These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 12735979)

  • 21. Activity standardization of two enriched
    Kossert K; Amelin Y; Arnold D; Merle R; Mougeot X; Schmiedel M; Zapata-García D
    Appl Radiat Isot; 2022 Oct; 188():110362. PubMed ID: 35839713
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of the NIST and BIPM Medium-Energy X-Ray Air-Kerma Measurements.
    Burns DT; O'Brien M; Lamperti P; Boutillon M
    J Res Natl Inst Stand Technol; 2003; 108(5):383-9. PubMed ID: 27413616
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determination of the intensity of X- and gamma-ray emissions in the decay of 153Sm.
    Lépy MC; Amiot MN; Bé MM; Cassette P
    Appl Radiat Isot; 2006; 64(10-11):1428-34. PubMed ID: 16580221
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER.
    Chu CH; Kuan WP; Kurosawa T; Lin UT; Chen IJ; Chen WL
    Radiat Prot Dosimetry; 2010 Feb; 138(2):99-106. PubMed ID: 19789201
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Precise measurements of the absolute γ-ray emission probabilities of (223)Ra and decay progeny in equilibrium.
    Collins SM; Pearce AK; Regan PH; Keightley JD
    Appl Radiat Isot; 2015 Aug; 102():15-28. PubMed ID: 25933406
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Determination of disintegration rates and gamma-ray emission probabilities of 65Zn and 241Am.
    Iwahara A; Aguiar Leobino da Silva M; Edsom Carvalho Filho A; Bernardes EM; Delgado JU
    Appl Radiat Isot; 2005 Jul; 63(1):107-13. PubMed ID: 15866455
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays.
    Burns DT; O'Brien M
    J Res Natl Inst Stand Technol; 2006; 111(5):385-91. PubMed ID: 27274940
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Some specific features of ionization chamber calibrations in linac x-ray beams at the LNE-LNHB.
    Delaunay F; Ostrowsky A
    Phys Med Biol; 2007 May; 52(9):N207-11. PubMed ID: 17440237
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of ionization chamber efficiencies for activity measurements.
    Schrader H; Svec A
    Appl Radiat Isot; 2004; 60(2-4):369-78. PubMed ID: 14987670
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Gamma-ray emission probabilities in the decay of (177m)Lu.
    Kondev FG; Ahmad I; Carpenter MP; Greene JP; Janssens RV; Lauritsen T; Seweryniak D; Zhu S; Lalkovski SP; Chowdhury P
    Appl Radiat Isot; 2012 Sep; 70(9):1867-70. PubMed ID: 22401939
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Standardisation and decay data of 177Lu and 188Re.
    Schötzig U; Schrader H; Schönfeld E; Günther E; Klein R
    Appl Radiat Isot; 2001 Jul; 55(1):89-96. PubMed ID: 11339536
    [TBL] [Abstract][Full Text] [Related]  

  • 32. 166mHo: a multi-gamma standard for the calibration of Ge spectrometers.
    Bernardes EM; Delgado JU; Tauhata L; da Silva CJ; Iwahara A; Poledna R; Paschoa AS
    Appl Radiat Isot; 2002; 56(1-2):157-61. PubMed ID: 11842800
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effective production of ⁶⁵Zn with a PET cyclotron.
    Lucconi G; Cicoria G; Pancaldi D; Malizia C; Marengo M
    Appl Radiat Isot; 2012 Aug; 70(8):1590-4. PubMed ID: 22732395
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Disintegration rate and gamma ray emission probability per decay measurement of 123I.
    Koskinas MF; Gishitomi KC; Brito AB; Yamazaki IM; Dias MS
    Appl Radiat Isot; 2012 Sep; 70(9):2091-6. PubMed ID: 22425419
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of absolute γ-ray emission probabilities in the decay of
    Marouli M; Lutter G; Pommé S; Van Ammel R; Hult M; Richter S; Eykens R; Peyrés V; García-Toraño E; Dryák P; Mazánová M; Carconi P
    Appl Radiat Isot; 2018 Feb; 132():72-78. PubMed ID: 29169063
    [TBL] [Abstract][Full Text] [Related]  

  • 36. International exercise on 124Sb activity measurements.
    Chauvenet B; Bé MM; Amiot MN; Bobin C; Lépy MC; Branger T; Lanièce I; Luca A; Sahagia M; Wätjen AC; Kossert K; Ott O; Nähle O; Dryák P; Sochorovà J; Kovar P; Auerbach P; Altzitzoglou T; Pommé S; Sibbens G; Van Ammel R; Paepen J; Iwahara A; Delgado JU; Poledna R; da Silva CJ; Johansson L; Stroak A; Bailat C; Nedjadi Y; Spring P
    Appl Radiat Isot; 2010; 68(7-8):1207-10. PubMed ID: 20153206
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of X- and gamma-ray emission intensities in the decay of (131)I.
    Lépy MC; Brondeau L; Bobin C; Lourenço V; Thiam C; Bé MM
    Appl Radiat Isot; 2016 Mar; 109():154-159. PubMed ID: 26651173
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of HPGe detector response using MCNP5 for 20-150 keV X-rays.
    Salgado CM; Conti CC; Becker PH
    Appl Radiat Isot; 2006 Jun; 64(6):700-5. PubMed ID: 16427294
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The standardization of samarium-153.
    Coursey BM; Hoppes DD; Schima FJ; Unterweger MP
    Int J Rad Appl Instrum A; 1987; 38(1):31-4. PubMed ID: 3030966
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Standardization of
    Bobin C; Thiam C; Bouchard J
    Appl Radiat Isot; 2018 Apr; 134():252-256. PubMed ID: 28676277
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.