119 related articles for article (PubMed ID: 12738337)
1. Commissioning and clinical results utilizing the Gildenberg-Laitinen Adapter Device for X-ray in fractionated stereotactic radiotherapy.
Ashamalla H; Addeo D; Ikoro NC; Ross P; Cosma M; Nasr N
Int J Radiat Oncol Biol Phys; 2003 Jun; 56(2):592-8. PubMed ID: 12738337
[TBL] [Abstract][Full Text] [Related]
2. Clinical commissioning of Laitinen Stereoadapter for fractionated stereotactic radiotherapy.
Weidlich GA; Gebert JA; Fuery JJ
Med Dosim; 1998; 23(4):302-6. PubMed ID: 9863732
[TBL] [Abstract][Full Text] [Related]
3. Simple invasive fixation device for fractionated stereotactic LINAC based radiotherapy.
Ganslandt O; Mueller R; Mueller W; Borchert H; Grabenbauer GG
Acta Neurochir (Wien); 2003 Apr; 145(4):289-94; discussion 294. PubMed ID: 12748889
[TBL] [Abstract][Full Text] [Related]
4. Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy.
Kooy HM; Dunbar SF; Tarbell NJ; Mannarino E; Ferarro N; Shusterman S; Bellerive M; Finn L; McDonough CV; Loeffler JS
Int J Radiat Oncol Biol Phys; 1994 Oct; 30(3):685-91. PubMed ID: 7928501
[TBL] [Abstract][Full Text] [Related]
5. The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: measurement of the repositioning accuracy.
Salter BJ; Fuss M; Vollmer DG; Sadeghi A; Bogaev CA; Cheek DA; Herman TS; Hevezi JM
Int J Radiat Oncol Biol Phys; 2001 Oct; 51(2):555-62. PubMed ID: 11567832
[TBL] [Abstract][Full Text] [Related]
6. Treatment accuracy of fractionated stereotactic radiotherapy.
Kumar S; Burke K; Nalder C; Jarrett P; Mubata C; A'hern R; Humphreys M; Bidmead M; Brada M
Radiother Oncol; 2005 Jan; 74(1):53-9. PubMed ID: 15683670
[TBL] [Abstract][Full Text] [Related]
7. Dosimetry and mechanical accuracy of the first rotating gamma system installed in North America.
Kubo HD; Araki F
Med Phys; 2002 Nov; 29(11):2497-505. PubMed ID: 12462714
[TBL] [Abstract][Full Text] [Related]
8. Patient position reproducibility in fractionated stereotactically guided conformal radiotherapy using the BrainLab mask system.
Alheit H; Dornfeld S; Dawel M; Alheit M; Henzel B; Steckler K; Blank H; Geyer P
Strahlenther Onkol; 2001 May; 177(5):264-8. PubMed ID: 11398613
[TBL] [Abstract][Full Text] [Related]
9. To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy.
Babic S; Lee Y; Ruschin M; Lochray F; Lightstone A; Atenafu E; Phan N; Mainprize T; Tsao M; Soliman H; Sahgal A
J Appl Clin Med Phys; 2018 Mar; 19(2):111-120. PubMed ID: 29363282
[TBL] [Abstract][Full Text] [Related]
10. The use of a Leksell-BRW adapter for linac radiosurgery as an adjunct to Gamma Knife treatment.
Ekstrand KE; Hinson WH; Bourland JD; deGuzman AF; Stieber VW; Tatter SB; Ellis TL
Phys Med Biol; 2003 Dec; 48(24):4105-10. PubMed ID: 14727754
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of relocation, evaluation of geometric uncertainties and clinical target volume (CTV) to planning target volume (PTV) margin in fractionated stereotactic radiotherapy for intracranial tumors using relocatable Gill-Thomas-Cosman (GTC) frame.
Das S; Isiah R; Rajesh B; Ravindran BP; Singh RR; Backianathan S; Subhashini J
J Appl Clin Med Phys; 2010 Dec; 12(2):3260. PubMed ID: 21587166
[TBL] [Abstract][Full Text] [Related]
12. Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy.
Bednarz G; Machtay M; Werner-Wasik M; Downes B; Bogner J; Hyslop T; Galvin J; Evans J; Curran W; Andrews D
Med Phys; 2009 Jan; 36(1):12-7. PubMed ID: 19235368
[TBL] [Abstract][Full Text] [Related]
13. Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment.
Shiu AS; Kooy HM; Ewton JR; Tung SS; Wong J; Antes K; Maor MH
Int J Radiat Oncol Biol Phys; 1997 Feb; 37(3):679-88. PubMed ID: 9112467
[TBL] [Abstract][Full Text] [Related]
14. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans.
Kubo HD; Wilder RB; Pappas CT
Int J Radiat Oncol Biol Phys; 1999 Jul; 44(4):937-45. PubMed ID: 10386653
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: the GammaPod™.
Mutaf YD; Zhang J; Yu CX; Yi BY; Prado K; D'Souza WD; Regine WF; Feigenberg SJ
Med Phys; 2013 Apr; 40(4):041722. PubMed ID: 23556892
[TBL] [Abstract][Full Text] [Related]
16. Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit.
Das IJ; Downes MB; Corn BW; Curran WJ; Werner-Wasik M; Andrews DW
Radiother Oncol; 1996 Jan; 38(1):61-8. PubMed ID: 8850427
[TBL] [Abstract][Full Text] [Related]
17. [Evaluation of positioning reproducibility using a re-locatable head frame for stereotactic radiotherapy].
Miyabe Y; Yano S; Okada T; Nakata M; Teshima T; Nagata Y; Hiraoka M
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Oct; 60(10):1444-51. PubMed ID: 15565014
[TBL] [Abstract][Full Text] [Related]
18. Study on dosimetric parameters for stereotactic radiosurgery and intensity-modulated radiotherapy.
Sankaranarayanan V; Ganesan S; Oommen S; Padmanaban TK; Stumpf J; Ayyangar KM
Med Dosim; 2003; 28(2):85-90. PubMed ID: 12804705
[TBL] [Abstract][Full Text] [Related]
19. Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT.
Wang L; Li J; Paskalev K; Hoban P; Luo W; Chen L; McNeeley S; Price R; Ma C
J Appl Clin Med Phys; 2006; 7(1):21-34. PubMed ID: 16518314
[TBL] [Abstract][Full Text] [Related]
20. 2D/3D image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions.
Jin JY; Ryu S; Faber K; Mikkelsen T; Chen Q; Li S; Movsas B
Med Phys; 2006 Dec; 33(12):4557-66. PubMed ID: 17278807
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]