119 related articles for article (PubMed ID: 12745428)
41. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants.
Patterson EA; Johns RB
Int J Oral Maxillofac Implants; 1992; 7(1):26-33. PubMed ID: 1398820
[TBL] [Abstract][Full Text] [Related]
42. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
[TBL] [Abstract][Full Text] [Related]
43. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis.
Chun HJ; Shin HS; Han CH; Lee SH
Int J Oral Maxillofac Implants; 2006; 21(2):195-202. PubMed ID: 16634489
[TBL] [Abstract][Full Text] [Related]
44. Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading.
Cheung G; Zalzal P; Bhandari M; Spelt JK; Papini M
Med Eng Phys; 2004 Mar; 26(2):93-108. PubMed ID: 15036177
[TBL] [Abstract][Full Text] [Related]
45. Selection of the implant transgingival height for optimal biomechanical properties: a three-dimensional finite element analysis.
Sun Y; Kong L; Hu K; Xie C; Zhou H; Liu Y; Liu B
Br J Oral Maxillofac Surg; 2009 Jul; 47(5):393-8. PubMed ID: 18977057
[TBL] [Abstract][Full Text] [Related]
46. Influence of marginal bone resorption on stress around an implant--a three-dimensional finite element analysis.
Kitamura E; Stegaroiu R; Nomura S; Miyakawa O
J Oral Rehabil; 2005 Apr; 32(4):279-86. PubMed ID: 15790383
[TBL] [Abstract][Full Text] [Related]
47. Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis.
Natali AN; Pavan PG; Ruggero AL
Dent Mater; 2006 Apr; 22(4):388-95. PubMed ID: 16198407
[TBL] [Abstract][Full Text] [Related]
48. Effects of bone materials on the screw pull-out strength in human spine.
Zhang QH; Tan SH; Chou SM
Med Eng Phys; 2006 Oct; 28(8):795-801. PubMed ID: 16414303
[TBL] [Abstract][Full Text] [Related]
49. [3D finite element analysis of bone stress around distally osseointegrated implant for artificial limb attachment].
Zheng L; Luo J; Wang X; Chen J; Gu Z; Zhang X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Jun; 24(3):554-7. PubMed ID: 17713260
[TBL] [Abstract][Full Text] [Related]
50. A method of quantification of stress shielding in the proximal femur using hierarchical computational modeling.
Be'ery-Lipperman M; Gefen A
Comput Methods Biomech Biomed Engin; 2006 Feb; 9(1):35-44. PubMed ID: 16880155
[TBL] [Abstract][Full Text] [Related]
51. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
Peleg E; Mosheiff R; Liebergall M; Mattan Y
Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
[TBL] [Abstract][Full Text] [Related]
52. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
[TBL] [Abstract][Full Text] [Related]
53. On the role of number of fixtures, surgical technique and timing of loading.
Eliasson A
Swed Dent J Suppl; 2008; (197):3-95. PubMed ID: 18652085
[TBL] [Abstract][Full Text] [Related]
54. Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: a 3D finite element analysis.
Simşek B; Erkmen E; Yilmaz D; Eser A
Med Eng Phys; 2006 Apr; 28(3):199-213. PubMed ID: 15979921
[TBL] [Abstract][Full Text] [Related]
55. Nonlinear elastic material property estimation of lower extremity residual limb tissues.
Tönük E; Silver-Thorn MB
IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):43-53. PubMed ID: 12797725
[TBL] [Abstract][Full Text] [Related]
56. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis.
Petrie CS; Williams JL
Clin Oral Implants Res; 2005 Aug; 16(4):486-94. PubMed ID: 16117775
[TBL] [Abstract][Full Text] [Related]
57. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses.
Chao CK; Hsu CC; Wang JL; Lin J
J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719
[TBL] [Abstract][Full Text] [Related]
58. Finite element analysis of four thread-form configurations in a stepped screw implant.
Geng JP; Ma QS; Xu W; Tan KB; Liu GR
J Oral Rehabil; 2004 Mar; 31(3):233-9. PubMed ID: 15025655
[TBL] [Abstract][Full Text] [Related]
59. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
Papini M; Zdero R; Schemitsch EH; Zalzal P
J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
[TBL] [Abstract][Full Text] [Related]
60. Combined influence of implant diameter and alveolar ridge width on crestal bone stress: a quantitative approach.
Yu W; Jang YJ; Kyung HM
Int J Oral Maxillofac Implants; 2009; 24(1):88-95. PubMed ID: 19344030
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]