These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 12757674)

  • 1. Percutaneous renal biopsy by automated biopsy gun.
    Ahmed AM; Anees M; Riaz A; Mueed S
    J Coll Physicians Surg Pak; 2003 May; 13(5):263-6. PubMed ID: 12757674
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A randomized, prospective, comparative study of manual and automated renal biopsies.
    Kim D; Kim H; Shin G; Ku S; Ma K; Shin S; Gi H; Lee E; Yim H
    Am J Kidney Dis; 1998 Sep; 32(3):426-31. PubMed ID: 9740159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasound-guided renal biopsy with biopsy gun technique--efficacy and complications.
    Christensen J; Lindequist S; Knudsen DU; Pedersen RS
    Acta Radiol; 1995 May; 36(3):276-9. PubMed ID: 7742122
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transjugular renal biopsy: our experience and technical considerations.
    See TC; Thompson BC; Howie AJ; Karamshi M; Papadopoulou AM; Davies N; Tibballs J
    Cardiovasc Intervent Radiol; 2008; 31(5):906-18. PubMed ID: 18266029
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous renal biopsy in children.
    Sumboonnanonda A; Srajai K; Vongjirad A; Suntornpoch V; Parichatikanond P
    J Med Assoc Thai; 2002 Aug; 85 Suppl 2():S755-61. PubMed ID: 12403257
    [TBL] [Abstract][Full Text] [Related]  

  • 6. No change in complication rate using spring-loaded gun compared to traditional percutaneous renal allograft biopsy techniques.
    Kovalik EC; Schwab SJ; Gunnells JC; Bowie D; Smith SR
    Clin Nephrol; 1996 Jun; 45(6):383-5. PubMed ID: 8793230
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Value of ultrasound-guided percutaneous renal biopsy in diagnosis of the renal diseases].
    Horvatić I; Hrkać A; Zivko M; Kozjak D; Galesić K
    Acta Med Croatica; 2007 Sep; 61(4):399-403. PubMed ID: 18044476
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A new automated renal biopsy technique under ultrasound guidance].
    Ohmori H; Arimoto K; Taki M; Kosaka K; Kumon H; Ohmori H
    Nihon Jinzo Gakkai Shi; 1990 Apr; 32(4):409-14. PubMed ID: 2198364
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Adequacy and complications of CT-guided percutaneous biopsy: a study of 334 cases in Srinagarind Hospital.
    Laopaiboon V; Aphinives C; Suporntreetriped K
    J Med Assoc Thai; 2009 Jul; 92(7):939-46. PubMed ID: 19626814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of percutaneous renal biopsy as a day case procedure: experience from Nigeria.
    Oviasu E; Ugbodaga P
    J Nephrol; 1998; 11(5):246-8. PubMed ID: 9831237
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Knowledge of renal histology alters patient management in over 40% of cases.
    Richards NT; Darby S; Howie AJ; Adu D; Michael J
    Nephrol Dial Transplant; 1994; 9(9):1255-9. PubMed ID: 7816285
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Core needle biopsy for bone tumours.
    Pramesh CS; Deshpande MS; Pardiwala DN; Agarwal MG; Puri A
    Eur J Surg Oncol; 2001 Nov; 27(7):668-71. PubMed ID: 11669596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of diagnostic quality of kidney biopsy obtained using 16G and 18G needles in patients with diffuse renal disease.
    Arora K; Punia RS; D'Cruz S
    Saudi J Kidney Dis Transpl; 2012 Jan; 23(1):88-92. PubMed ID: 22237225
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Theoretical calculation of optimal depth in the percutaneous native kidney biopsy to drastically reduce bleeding complications and sample inadequacy for histopathological diagnosis.
    Pasquariello A; Innocenti M; Batini V; Pasquariello G; Beati S; Rindi S; Paoletti S; Panichi V
    Nephrol Dial Transplant; 2007 Dec; 22(12):3516-20. PubMed ID: 17890249
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous renal biopsy: comparison of manual and automated puncture techniques with native and transplanted kidneys.
    Riehl J; Maigatter S; Kierdorf H; Schmitt H; Maurin N; Sieberth HG
    Nephrol Dial Transplant; 1994; 9(11):1568-74. PubMed ID: 7870344
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Percutaneous kidney biopsy, analysis of 26 years: complication rate and risk factors; comment].
    González-Michaca L; Chew-Wong A; Soltero L; Gamba G; Correa-Rotter R
    Rev Invest Clin; 2000; 52(2):125-31. PubMed ID: 10846435
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous renal biopsy: a single center experience with automated spring-loaded "gun" type device.
    Ballal SH; Nayak R; Dhanraj P; Kocher P; Bastani B
    Clin Nephrol; 1995 Oct; 44(4):274-5. PubMed ID: 8575130
    [No Abstract]   [Full Text] [Related]  

  • 18. Percutaneous renal biopsy: an audit of a 2 year experience with the Biopty gun.
    Voss DM; Lynn KL
    N Z Med J; 1995 Jan; 108(992):8-10. PubMed ID: 7862364
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Transjugular liver biopsy: retrospective study performed on 71 patients].
    Quevedo E; Tan J; Araujo G; Morales H; Távara F
    Rev Gastroenterol Peru; 2003; 23(4):254-8. PubMed ID: 14716419
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Percutaneous biopsy of the kidney in children (technical aspects)].
    Smoljanić Z; Marsenić O
    Srp Arh Celok Lek; 1996; 124 Suppl 1():220-1. PubMed ID: 9102914
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.