160 related articles for article (PubMed ID: 12759635)
1. Two-part and three-part fractures of the proximal humerus treated with suture fixation.
Park MC; Murthi AM; Roth NS; Blaine TA; Levine WN; Bigliani LU
J Orthop Trauma; 2003 May; 17(5):319-25. PubMed ID: 12759635
[TBL] [Abstract][Full Text] [Related]
2. Transosseous suture fixation of proximal humeral fractures.
Dimakopoulos P; Panagopoulos A; Kasimatis G
J Bone Joint Surg Am; 2007 Aug; 89(8):1700-9. PubMed ID: 17671007
[TBL] [Abstract][Full Text] [Related]
3. Transosseous suture fixation of proximal humeral fractures. Surgical technique.
Dimakopoulos P; Panagopoulos A; Kasimatis G
J Bone Joint Surg Am; 2009 Mar; 91 Suppl 2 Pt 1():8-21. PubMed ID: 19255196
[TBL] [Abstract][Full Text] [Related]
4. The results of tension band rotator cuff suture fixation of locked plating of displaced proximal humerus fractures.
Shukla DR; McAnany S; Pean C; Overley S; Lovy A; Parsons BO
Injury; 2017 Feb; 48(2):474-480. PubMed ID: 28063677
[TBL] [Abstract][Full Text] [Related]
5. High rate of avascular necrosis but excellent patient-reported outcomes after open reduction and internal fixation (ORIF) of proximal humerus fracture dislocations: should ORIF be considered as primary treatment?
Roddy E; Kandemir U
J Shoulder Elbow Surg; 2023 Oct; 32(10):2097-2104. PubMed ID: 37224914
[TBL] [Abstract][Full Text] [Related]
6. Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome.
Solberg BD; Moon CN; Franco DP; Paiement GD
J Orthop Trauma; 2009 Feb; 23(2):113-9. PubMed ID: 19169103
[TBL] [Abstract][Full Text] [Related]
7. Anterior traumatic shoulder dislocation associated with displaced greater tuberosity fracture: the necessity of operative treatment.
Dimakopoulos P; Panagopoulos A; Kasimatis G; Syggelos SA; Lambiris E
J Orthop Trauma; 2007 Feb; 21(2):104-12. PubMed ID: 17304065
[TBL] [Abstract][Full Text] [Related]
8. Proximal humeral nail for treatment of 3- and 4-part proximal humerus fractures in the elderly population: effective and safe in experienced hands.
Greenberg A; Rosinsky PJ; Gafni N; Kosashvili Y; Kaban A
Eur J Orthop Surg Traumatol; 2021 May; 31(4):769-777. PubMed ID: 33211233
[TBL] [Abstract][Full Text] [Related]
9. Proximal periarticular locking plates in proximal humeral fractures: functional outcomes.
Schulte LM; Matteini LE; Neviaser RJ
J Shoulder Elbow Surg; 2011 Dec; 20(8):1234-40. PubMed ID: 21420322
[TBL] [Abstract][Full Text] [Related]
10. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.
Somasundaram K; Huber CP; Babu V; Zadeh H
Injury; 2013 Apr; 44(4):481-7. PubMed ID: 23199758
[TBL] [Abstract][Full Text] [Related]
11. Surgical treatment of complex fracture of the proximal humerus.
Ko JY; Yamamoto R
Clin Orthop Relat Res; 1996 Jun; (327):225-37. PubMed ID: 8641068
[TBL] [Abstract][Full Text] [Related]
12. Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?
Liao W; Zhang H; Li Z; Li J
Clin Orthop Relat Res; 2016 May; 474(5):1269-79. PubMed ID: 26728514
[TBL] [Abstract][Full Text] [Related]
13. Arthroscopic percutaneous inverted mattress suture fixation of isolated greater tuberosity fracture of humerus.
Jang SH; Song HE; Choi SH
J Orthop Surg (Hong Kong); 2018; 26(1):2309499017754108. PubMed ID: 29382295
[TBL] [Abstract][Full Text] [Related]
14. Arthroscopic-assisted plate fixation for displaced large-sized comminuted greater tuberosity fractures of proximal humerus: a novel surgical technique.
Park SE; Jeong JJ; Panchal K; Lee JY; Min HK; Ji JH
Knee Surg Sports Traumatol Arthrosc; 2016 Dec; 24(12):3892-3898. PubMed ID: 26419378
[TBL] [Abstract][Full Text] [Related]
15. Radiographic and clinical results of tension suture fixation using two washers with PHILOS plate for proximal humeral fractures.
Cho CH; Kim DH; Kim BS
Injury; 2017 Feb; 48(2):464-468. PubMed ID: 27914660
[TBL] [Abstract][Full Text] [Related]
16. Surgical treatment of proximal humeral fractures with the transosseous suture fixation.
Miquel J; Martínez R; Santana F; Marimon P; Torrens C
J Orthop Surg Res; 2021 Jun; 16(1):405. PubMed ID: 34162416
[TBL] [Abstract][Full Text] [Related]
17. Locking plate fixation of three- and four-part proximal humeral fractures.
Parmaksizoğlu AS; Sökücü S; Ozkaya U; Kabukçuoğlu Y; Gül M
Acta Orthop Traumatol Turc; 2010; 44(2):97-104. PubMed ID: 20676010
[TBL] [Abstract][Full Text] [Related]
18. Results of proximal humeral locked plating with supplemental suture fixation of rotator cuff.
Badman B; Frankle M; Keating C; Henderson L; Brooks J; Mighell M
J Shoulder Elbow Surg; 2011 Jun; 20(4):616-24. PubMed ID: 21167741
[TBL] [Abstract][Full Text] [Related]
19. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate.
Erasmo R; Guerra G; Guerra L
Injury; 2014 Dec; 45 Suppl 6():S43-8. PubMed ID: 25457318
[TBL] [Abstract][Full Text] [Related]
20. Use of locking plates in the treatment of proximal humerus fractures.
Ricchetti ET; Warrender WJ; Abboud JA
J Shoulder Elbow Surg; 2010 Mar; 19(2 Suppl):66-75. PubMed ID: 20188270
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]