180 related articles for article (PubMed ID: 1276024)
1. Towards blood-gas autoanalysis an evaluation of the radiometer ABL.
Selman BJ; Tait AR
Br J Anaesth; 1976 May; 48(5):487-94. PubMed ID: 1276024
[TBL] [Abstract][Full Text] [Related]
2. [Analytical reliability of the results of determining pH, pCO2 and pO2 with the ABL 300 (Radiometer) automatic pH and blood gas analyzer].
Tsachev K; Dochev D; Tikholov I
Vutr Boles; 1988; 27(4):77-81. PubMed ID: 3145645
[TBL] [Abstract][Full Text] [Related]
3. [Blood gas measurements and automatization (author's transl)].
Clerbaux T; Vanhove P; Nullens W; Brasseur L
Bull Eur Physiopathol Respir; 1977; 13(2):285-97. PubMed ID: 16678
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of an automated blood-gas analyser operated by untrained staff.
Minty BD; Barrett AM
Br J Anaesth; 1978 Oct; 50(10):1031-9. PubMed ID: 30464
[TBL] [Abstract][Full Text] [Related]
5. Comparative study of automatic blood-gas analysers and their use in analysing arterial and capillary samples.
Rubin P; Bradbury S; Prowse K
Br Med J; 1979 Jan; 1(6157):156-8. PubMed ID: 33741
[TBL] [Abstract][Full Text] [Related]
6. A comparative study of the electrode systems of three pH and blood gas apparatus.
Winckers EK; Teunissen AJ; Van den Camp RA; Maas AH
J Clin Chem Clin Biochem; 1978 Mar; 16(3):175-85. PubMed ID: 25944
[TBL] [Abstract][Full Text] [Related]
7. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision.
Venkatesh B; Boots RJ
J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053
[TBL] [Abstract][Full Text] [Related]
8. Comparison of blood gas and electrolyte test results from the Gem-Premier and the ABL-70 versus a conventional laboratory analyzer.
Walton HG; Boucher DM; Marroquin R
J Extra Corpor Technol; 2003 Mar; 35(1):24-7. PubMed ID: 12680492
[TBL] [Abstract][Full Text] [Related]
9. Accuracy and precision of a new, portable, handheld blood gas analyzer, the IRMA.
Wahr JA; Lau W; Tremper KK; Hallock L; Smith K
J Clin Monit; 1996 Jul; 12(4):317-24. PubMed ID: 8863112
[TBL] [Abstract][Full Text] [Related]
10. Problems with the gas-calibrated PCO2 electrode.
Bateman NT; Musch TI; Smith CA; Dempsey JA
Respir Physiol; 1980 Aug; 41(2):217-26. PubMed ID: 6776600
[TBL] [Abstract][Full Text] [Related]
11. A portable blood gas analyzer for equine venous blood.
Mitten LA; Hinchcliff KW; Sams R
J Vet Intern Med; 1995; 9(5):353-6. PubMed ID: 8531183
[TBL] [Abstract][Full Text] [Related]
12. Use of carbon dioxide- and oxygen-tonometered phosphate-bicarbonate-chloride-glycerol-water mixtures for calibration and control of pH, pCO2, and pO2 electrode systems.
Veefkind AH; Van den Camp RA; Maas AH
Clin Chem; 1975 May; 21(6):685-93. PubMed ID: 235377
[TBL] [Abstract][Full Text] [Related]
13. [Pertinence of simultaneous measurements of pO2 and sO2 on ABL 510].
Gouget B; Manene D; Andrimahatratra R; Bogard M; Gourmelin Y
Ann Biol Clin (Paris); 1992; 50(4):247-50. PubMed ID: 1456503
[TBL] [Abstract][Full Text] [Related]
14. A disposable in vivo oxygen electrode for the continuous measurement of arterial oxygen tension.
Gold MI; Diaz PM; Feingold A; Duarte I; Sohn YJ; Kallos T
Surgery; 1975 Aug; 78(2):245-50. PubMed ID: 1154267
[TBL] [Abstract][Full Text] [Related]
15. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer.
Zenger M; Brenner M; Hua P; Haruno M; Wilson AF
Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286
[TBL] [Abstract][Full Text] [Related]
16. Comparison of blood gas analyzer biases in measuring tonometered blood and a fluorocarbon-containing, proficiency-testing material.
Hansen JE; Jensen RL; Casaburi R; Crapo RO
Am Rev Respir Dis; 1989 Aug; 140(2):403-9. PubMed ID: 2504088
[TBL] [Abstract][Full Text] [Related]
17. [The i-STAT analyzer. A new, hand-held device for the bedside determination of hematocrit, blood gases, and electrolytes].
Schneider J; Dudziak R; Westphal K; Vettermann J
Anaesthesist; 1997 Aug; 46(8):704-14. PubMed ID: 9382209
[TBL] [Abstract][Full Text] [Related]
18. Accuracy of the i-STAT bedside blood gas analyser.
Sediame S; Zerah-Lancner F; d'Ortho MP; Adnot S; Harf A
Eur Respir J; 1999 Jul; 14(1):214-7. PubMed ID: 10489854
[TBL] [Abstract][Full Text] [Related]
19. Measurement of blood O2 and CO2 concentrations using PO2 and PCO2 electrodes.
Harabin AL; Farhi LE
J Appl Physiol Respir Environ Exerc Physiol; 1978 May; 44(5):818-20. PubMed ID: 565765
[TBL] [Abstract][Full Text] [Related]
20. Clinical evaluation of the on-line Sensicath blood gas monitoring system.
Myklejord DJ; Pritzker MR; Nicoloff DM; Emery AM; Emery RW
Heart Surg Forum; 1998; 1(1):60-4. PubMed ID: 11276442
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]