These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 12763949)

  • 21. Evaluation of risk of deterministic effects in fluoroscopically guided procedures.
    Vano E; Gonzalez L; Guibelalde E; Aviles P; Fernandez JM; Prieto C; Galvan C
    Radiat Prot Dosimetry; 2005; 117(1-3):190-4. PubMed ID: 16461530
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Present Situation of Fluoroscopy Radiation Doses in Many IVR Systems].
    Inaba Y; Kobayashi R; Chida K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2016 Aug; 72(8):689-94. PubMed ID: 27546083
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Skin dose and dose-area product values in patients undergoing intracoronary brachytherapy.
    Vano E; Prieto C; Fernandez JM; Gonzalez L; Sabate M; Galvan C
    Br J Radiol; 2003 Jan; 76(901):32-8. PubMed ID: 12595323
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Patient skin dose in cardiac interventional procedures: conventional fluoroscopy versus pulsed fluoroscopy.
    Chida K; Fuda K; Saito H; Takai Y; Takahashi S; Yamada S; Kohzuki M; Zuguchi M
    Catheter Cardiovasc Interv; 2007 Jan; 69(1):115-21; discussion 122. PubMed ID: 17139653
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Coronary angiography and percutaneous transluminal coronary angioplasty procedures: Evaluation of patients' maximum skin dose using Gafchromic films and a comparison of local levels with reference levels proposed in the literature.
    Giordano C; D'Ercole L; Gobbi R; Bocchiola M; Passerini F
    Phys Med; 2010 Oct; 26(4):224-32. PubMed ID: 20117030
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Proposed preliminary diagnostic reference levels for three common interventional cardiology procedures in Ireland.
    D'Helft C; McGee A; Rainford L; McFadden S; Winder J; Hughes C; Brennan PC
    Radiat Prot Dosimetry; 2008; 129(1-3):63-6. PubMed ID: 18420567
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Radiation dose of interventional radiology system using a flat-panel detector.
    Chida K; Inaba Y; Saito H; Ishibashi T; Takahashi S; Kohzuki M; Zuguchi M
    AJR Am J Roentgenol; 2009 Dec; 193(6):1680-5. PubMed ID: 19933664
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
    Rampado O; Garelli E; Deagostini S; Ropolo R
    Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Patient dose related to the complexity of interventional cardiology procedures.
    Padovani R; Bernardi G; Malisan MR; Vañó E; Morocutti G; Fioretti PM
    Radiat Prot Dosimetry; 2001; 94(1-2):189-92. PubMed ID: 11487833
    [TBL] [Abstract][Full Text] [Related]  

  • 30. X-ray dose to the skin in patients undergoing percutaneous transluminal coronary angioplasty.
    Miralbell R; Doriot PA; Nouet P; Rouzaud M
    Catheter Cardiovasc Interv; 2000 Jul; 50(3):300-6. PubMed ID: 10878626
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Patient dosimetry in interventional cardiology at the University Hospital of Osijek.
    Faj D; Steiner R; Trifunovic D; Faj Z; Kasabasic M; Kubelka D; Brnic Z
    Radiat Prot Dosimetry; 2008; 128(4):485-90. PubMed ID: 17921512
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em.dose.
    Greffier J; Van Ngoc Ty C; Bonniaud G; Moliner G; Ledermann B; Schmutz L; Cornillet L; Cayla G; Beregi JP; Pereira F
    Phys Med; 2017 Jun; 38():16-22. PubMed ID: 28610693
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Review of patient dosimetry in cardiology.
    Neofotistou V
    Radiat Prot Dosimetry; 2001; 94(1-2):177-82. PubMed ID: 11487831
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Vendor-independent skin dose mapping application for interventional radiology and cardiology.
    Krajinović M; Kržanović N; Ciraj-Bjelac O
    J Appl Clin Med Phys; 2021 Feb; 22(2):145-157. PubMed ID: 33440056
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of a conventional and a flat-panel digital system in interventional cardiology procedures.
    Tsapaki V; Kottou S; Kollaros N; Dafnomili P; Koutelou M; Vano E; Neofotistou V
    Br J Radiol; 2004 Jul; 77(919):562-7. PubMed ID: 15238402
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of methods to estimate the patient dose in interventional radiology.
    Kosunen A; Komppa T; Toivonen M
    Radiat Prot Dosimetry; 2005; 117(1-3):178-84. PubMed ID: 16464835
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Physicians' radiation exposure in the catheterization lab: does the type of procedure matter?
    Ingwersen M; Drabik A; Kulka U; Oestreicher U; Fricke S; Krankenberg H; Schwencke C; Mathey D
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1095-102. PubMed ID: 24156970
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures.
    Ohuchi H; Satoh T; Eguchi Y; Mori K
    Radiat Prot Dosimetry; 2005; 117(4):432-9. PubMed ID: 15985500
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An estimate of the collective dose to the European population from cardiac X-ray procedures.
    Faulkner K; Werduch A
    Br J Radiol; 2008 Dec; 81(972):955-62. PubMed ID: 19029053
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of the radiation dose in a cardiac IVR X-ray system.
    Inaba Y; Chida K; Shirotori K; Shimura H; Yanagawa I; Zuguchi M; Takahashi S
    Radiat Prot Dosimetry; 2011 Jan; 143(1):74-80. PubMed ID: 21081517
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.