These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 12765446)

  • 21. Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloaded wavelet-transform morphology algorithm: a paradigm for development of implantable cardioverter defibrillator detection algorithms.
    Swerdlow CD; Brown ML; Lurie K; Zhang J; Wood NM; Olson WH; Gillberg JM
    J Cardiovasc Electrophysiol; 2002 May; 13(5):432-41. PubMed ID: 12030523
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pitfalls of the concept of incremental specificity used in comparisons of dual chamber VT/VF detection algorithms.
    Malik M
    Pacing Clin Electrophysiol; 2000 Jul; 23(7):1166-70. PubMed ID: 10914375
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Combined atrial and ventricular antitachycardia pacing as a novel method of rhythm discrimination: the Dynamic Discrimination Download Study.
    Saba S; Volosin K; Yee R; Swerdlow C; Brown M;
    Circulation; 2010 Feb; 121(4):487-97. PubMed ID: 20083678
    [TBL] [Abstract][Full Text] [Related]  

  • 24. SVT discrimination algorithms significantly reduce the rate of inappropriate therapy in the setting of modern-day delayed high-rate detection programming.
    Cheng A; Auricchio A; Schloss EJ; Kurita T; Sterns LD; Gerritse B; Brown ML; Fagan DH; Lexcen DR; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2877-2884. PubMed ID: 31646695
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Differentiation of ventricular and supraventricular tachycardias based on the analysis of the first postpacing interval after sequential anti-tachycardia pacing in implantable cardioverter-defibrillator patients.
    Arenal A; Ortiz M; Peinado R; Merino JL; Quesada A; Atienza F; Alberola AG; Ormaetxe J; Castellanos E; Rodriguez JC; Pérez N; García J; Boluda L; del Prado M; Artés A
    Heart Rhythm; 2007 Mar; 4(3):316-22. PubMed ID: 17341396
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators.
    Nanthakumar K; Paquette M; Newman D; Deno DC; Malden L; Gunderson B; Gilkerson J; Greene M; Heng D; Dorian P
    Am Heart J; 2000 May; 139(5):797-803. PubMed ID: 10783212
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Sensing and detection in Medtronic implantable cardioverter defibrillators.
    Brown ML; Swerdlow CD
    Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):193-212. PubMed ID: 27624809
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of a programming algorithm for the third tachycardia zone in a fourth-generation implantable cardioverter-defibrillator.
    Neglia JJ; Krol RB; Giorgberidze I; Mathew P; Lewis C; Munsif AN; Saksena S
    J Interv Card Electrophysiol; 1997 Feb; 1(1):49-56. PubMed ID: 9869951
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Morphology discrimination: a beat-to-beat algorithm for the discrimination of ventricular from supraventricular tachycardia by implantable cardioverter defibrillators.
    Grönefeld GC; Schulte B; Hohnloser SH; Trappe HJ; Korte T; Stellbrink C; Jung W; Meesmann M; Böcker D; Grosse-Meininghaus D; Vogt J;
    Pacing Clin Electrophysiol; 2001 Oct; 24(10):1519-24. PubMed ID: 11707046
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Reduction of inappropriate implantable cardioverter-defibrillator therapies using enhanced supraventricular tachycardia discriminators: the ReduceIT study.
    Geller JC; Wöhrle A; Busch M; Elsässer A; Kleemann T; Birkenhauer F; Bramlage P; Veltmann C;
    J Interv Card Electrophysiol; 2021 Aug; 61(2):339-348. PubMed ID: 32661865
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Diagnostic performance of a dual-chamber cardioverter defibrillator programmed with nominal settings: a European prospective study.
    Sadoul N; Jung W; Jordaens L; Leenhardt A; Santini M; Wolpert C; Aliot E;
    J Cardiovasc Electrophysiol; 2002 Jan; 13(1):25-32. PubMed ID: 11843479
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ventriculoatrial conduction metrics for classification of ventricular tachycardia with 1:1 retrograde conduction in dual-chamber sensing implantable cardioverter defibrillators.
    Thompson JA; Jenkins JM
    J Electrocardiol; 1998; 31 Suppl():152-6. PubMed ID: 9988021
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm.
    Grimm W; Menz V; Hoffmann J; Maisch B
    Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):722-7. PubMed ID: 9584303
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.
    Dijkman B; Wellens HJ
    J Cardiovasc Electrophysiol; 2000 Dec; 11(12):1309-19. PubMed ID: 11196552
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Long-term outcome after cardioverter-defibrillator implantation in patients with Brugada syndrome].
    Binbin Y; Jingping L; Bing Y; Minglong C; Jiangang Z; Kejiang C; Qijun S
    Zhonghua Xin Xue Guan Bing Za Zhi; 2015 Aug; 43(8):690-4. PubMed ID: 26955725
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO).
    Toquero J; Alzueta J; Mont L; Lozano IF; Barrera A; Berruezo A; Castro V; Peña JL; Fidalgo ML; Brugada J
    Europace; 2009 Jun; 11(6):727-33. PubMed ID: 19411676
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simultaneous atrial and ventricular anti-tachycardia pacing as a novel method of rhythm discrimination.
    Saba S; Baker L; Ganz L; Barrington W; Jain S; Ngwu O; Christensen J; Brown M
    J Cardiovasc Electrophysiol; 2006 Jul; 17(7):695-701. PubMed ID: 16836661
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance of an automatic external cardioverter-defibrillator algorithm in the discrimination of supraventricular from ventricular tachycardia.
    Mattioni T; Kanaan N; Riggio D; Bahu M; Lin D; Welch S; Williams C
    Am J Cardiol; 2003 Jun; 91(11):1323-6. PubMed ID: 12767424
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks.
    Beau S; Greer S; Ellis CR; Keeney J; Asopa S; Arnold E; Fischer A
    J Interv Card Electrophysiol; 2016 Mar; 45(2):225-32. PubMed ID: 26739482
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Safety and efficacy of a dual chamber implantable cardioverter defibrillator capable of slow ventricular tachycardia discrimination: a randomized study.
    Mletzko R; Aliot E; Seidl K; Lavergne T; Mabo P; Hohnloser S; Bocker D; Schoels W; Sadoul N
    Pacing Clin Electrophysiol; 2003 Dec; 26(12):2275-82. PubMed ID: 14675012
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.