279 related articles for article (PubMed ID: 12772984)
1. Evaluation of cost functions for gray value matching of two-dimensional images in radiotherapy.
Dekker N; Ploeger LS; van Herk M
Med Phys; 2003 May; 30(5):778-84. PubMed ID: 12772984
[TBL] [Abstract][Full Text] [Related]
2. Automated 2D-3D registration of portal images and CT data using line-segment enhancement.
Munbodh R; Chen Z; Jaffray DA; Moseley DJ; Knisely JP; Duncan JS
Med Phys; 2008 Oct; 35(10):4352-61. PubMed ID: 18975681
[TBL] [Abstract][Full Text] [Related]
3. Novel image registration quality evaluator (RQE) with an implementation for automated patient positioning in cranial radiation therapy.
Wu J; Samant SS
Med Phys; 2007 Jun; 34(6):2099-112. PubMed ID: 17654913
[TBL] [Abstract][Full Text] [Related]
4. Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT.
Chen T; Kim S; Goyal S; Jabbour S; Zhou J; Rajagopal G; Haffty B; Yue N
Med Phys; 2010 Jan; 37(1):197-210. PubMed ID: 20175482
[TBL] [Abstract][Full Text] [Related]
5. A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy.
Zhou J; Kim S; Jabbour S; Goyal S; Haffty B; Chen T; Levinson L; Metaxas D; Yue NJ
Med Phys; 2010 Mar; 37(3):1298-308. PubMed ID: 20384267
[TBL] [Abstract][Full Text] [Related]
6. Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: an evaluation of the setup verification process for the special case of a rigid head phantom.
Boswell S; Tomé W; Jeraj R; Jaradat H; Mackie TR
Med Phys; 2006 Nov; 33(11):4395-404. PubMed ID: 17153418
[TBL] [Abstract][Full Text] [Related]
7. 3D interfractional patient position verification using 2D-3D registration of orthogonal images.
Jans HS; Syme AM; Rathee S; Fallone BG
Med Phys; 2006 May; 33(5):1420-39. PubMed ID: 16752578
[TBL] [Abstract][Full Text] [Related]
8. 3D/2D image registration: the impact of X-ray views and their number.
Tomazevic D; Likar B; Pernus F
Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):450-7. PubMed ID: 18051090
[TBL] [Abstract][Full Text] [Related]
9. Automatic registration between reference and on-board digital tomosynthesis images for positioning verification.
Ren L; Godfrey DJ; Yan H; Wu QJ; Yin FF
Med Phys; 2008 Feb; 35(2):664-72. PubMed ID: 18383688
[TBL] [Abstract][Full Text] [Related]
10. Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification.
Park SJ; Ionascu D; Hacker F; Mamon H; Berbeco R
Med Phys; 2009 Oct; 36(10):4536-46. PubMed ID: 19928085
[TBL] [Abstract][Full Text] [Related]
11. Site-specific deformable imaging registration algorithm selection using patient-based simulated deformations.
Nie K; Chuang C; Kirby N; Braunstein S; Pouliot J
Med Phys; 2013 Apr; 40(4):041911. PubMed ID: 23556905
[TBL] [Abstract][Full Text] [Related]
12. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment.
Künzler T; Grezdo J; Bogner J; Birkfellner W; Georg D
Phys Med Biol; 2007 Apr; 52(8):2157-70. PubMed ID: 17404461
[TBL] [Abstract][Full Text] [Related]
13. A new algorithm for the registration of portal images to planning images in the verification of radiotherapy, as validated in prostate treatments.
Jobse M; Davelaar J; Hendriks E; Kattevilder R; Reiber H; Stoel B
Med Phys; 2003 Sep; 30(9):2274-81. PubMed ID: 14528947
[TBL] [Abstract][Full Text] [Related]
14. A novel intensity similarity metric with soft spatial constraint for a deformable image registration problem in radiation therapy.
Khamene A; Zikic D; Diallo M; Boettger T; Rietzel E
Med Image Comput Comput Assist Interv; 2009; 12(Pt 1):828-36. PubMed ID: 20426065
[TBL] [Abstract][Full Text] [Related]
15. Constrained non-rigid registration for use in image-guided adaptive radiotherapy.
Greene WH; Chelikani S; Purushothaman K; Knisely JP; Chen Z; Papademetris X; Staib LH; Duncan JS
Med Image Anal; 2009 Oct; 13(5):809-17. PubMed ID: 19682945
[TBL] [Abstract][Full Text] [Related]
16. Use and uncertainties of mutual information for computed tomography/ magnetic resonance (CT/MR) registration post permanent implant of the prostate.
Roberson PL; McLaughlin PW; Narayana V; Troyer S; Hixson GV; Kessler ML
Med Phys; 2005 Feb; 32(2):473-82. PubMed ID: 15789594
[TBL] [Abstract][Full Text] [Related]
17. Automatic coregistration of volumetric images based on implanted fiducial markers.
Koch M; Maltz JS; Belongie SJ; Gangadharan B; Bose S; Shukla H; Bani-Hashemi AR
Med Phys; 2008 Oct; 35(10):4513-23. PubMed ID: 18975698
[TBL] [Abstract][Full Text] [Related]
18. Fast elastic registration for adaptive radiotherapy.
Malsch U; Thieke C; Bendl R
Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):612-9. PubMed ID: 17354823
[TBL] [Abstract][Full Text] [Related]
19. Phantom validation of coregistration of PET and CT for image-guided radiotherapy.
Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM
Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296
[TBL] [Abstract][Full Text] [Related]
20. 2D-3D registration for prostate radiation therapy based on a statistical model of transmission images.
Munbodh R; Tagare HD; Chen Z; Jaffray DA; Moseley DJ; Knisely JP; Duncan JS
Med Phys; 2009 Oct; 36(10):4555-68. PubMed ID: 19928087
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]