351 related articles for article (PubMed ID: 12774149)
1. Improvements in surgical technique of valgus high tibial osteotomy.
Lobenhoffer P; Agneskirchner JD
Knee Surg Sports Traumatol Arthrosc; 2003 May; 11(3):132-8. PubMed ID: 12774149
[TBL] [Abstract][Full Text] [Related]
2. [Open valgus alignment osteotomy of the proximal tibia with fixation by medial plate fixator].
Lobenhoffer P; Agneskirchner J; Zoch W
Orthopade; 2004 Feb; 33(2):153-60. PubMed ID: 14872306
[TBL] [Abstract][Full Text] [Related]
3. Fixator-assisted Technique Enables Less Invasive Plate Osteosynthesis in Medial Opening-wedge High Tibial Osteotomy: A Novel Technique.
Lee DH; Ryu KJ; Kim JH; Soung S; Shin S
Clin Orthop Relat Res; 2015 Oct; 473(10):3133-42. PubMed ID: 26022111
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy.
Marti CB; Gautier E; Wachtl SW; Jakob RP
Arthroscopy; 2004 Apr; 20(4):366-72. PubMed ID: 15067275
[TBL] [Abstract][Full Text] [Related]
5. [Closing-wedge high tibial osteotomy with a modified Weber technique].
Frey P; Müller M; Munzinger U
Oper Orthop Traumatol; 2008 Mar; 20(1):75-88. PubMed ID: 18338121
[TBL] [Abstract][Full Text] [Related]
6. [Fixation of proximal tibia medial opening wedge osteotomy using plates with wedges].
Esenkaya I
Acta Orthop Traumatol Turc; 2005; 39(3):211-23. PubMed ID: 16141727
[TBL] [Abstract][Full Text] [Related]
7. Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique.
van Raaij TM; Brouwer RW; de Vlieger R; Reijman M; Verhaar JA
Acta Orthop; 2008 Aug; 79(4):508-14. PubMed ID: 18766484
[TBL] [Abstract][Full Text] [Related]
8. Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls.
Madry H; Goebel L; Hoffmann A; Dück K; Gerich T; Seil R; Tschernig T; Pape D
Knee Surg Sports Traumatol Arthrosc; 2017 Dec; 25(12):3661-3669. PubMed ID: 27236541
[TBL] [Abstract][Full Text] [Related]
9. Opening wedge tibial osteotomy: the 3-triangle method to correct axial alignment and tibial slope.
Noyes FR; Goebel SX; West J
Am J Sports Med; 2005 Mar; 33(3):378-87. PubMed ID: 15716253
[TBL] [Abstract][Full Text] [Related]
10. Control of posterior tibial slope and patellar height in open-wedge valgus high tibial osteotomy.
Hinterwimmer S; Beitzel K; Paul J; Kirchhoff C; Sauerschnig M; von Eisenhart-Rothe R; Imhoff AB
Am J Sports Med; 2011 Apr; 39(4):851-6. PubMed ID: 21212305
[TBL] [Abstract][Full Text] [Related]
11. Implementation, accuracy evaluation, and preliminary clinical trial of a CT-free navigation system for high tibial opening wedge osteotomy.
Wang G; Zheng G; Keppler P; Gebhard F; Staubli A; Mueller U; Schmucki D; Fluetsch S; Nolte LP
Comput Aided Surg; 2005 Mar; 10(2):73-85. PubMed ID: 16298918
[TBL] [Abstract][Full Text] [Related]
12. [Medial opening-wedge high tibial valgus osteotomy, using a stable TomoFix plate, in genu varum arthritis: surgical technique].
Horácek D; Cech O; Weissinger M
Acta Chir Orthop Traumatol Cech; 2006 Jun; 73(3):197-204. PubMed ID: 16846566
[TBL] [Abstract][Full Text] [Related]
13. The advantages of circular external fixation used in high tibial osteotomy (average 6 years follow-up).
Sen C; Kocaoglu M; Eralp L
Knee Surg Sports Traumatol Arthrosc; 2003 May; 11(3):139-44. PubMed ID: 12669193
[TBL] [Abstract][Full Text] [Related]
14. [Opening-wedge osteotomy of the proximal tibia].
Prix R
Acta Chir Orthop Traumatol Cech; 2005; 72(5):308-12. PubMed ID: 16316607
[TBL] [Abstract][Full Text] [Related]
15. Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases.
Brosset T; Pasquier G; Migaud H; Gougeon F
Orthop Traumatol Surg Res; 2011 Nov; 97(7):705-11. PubMed ID: 22001198
[TBL] [Abstract][Full Text] [Related]
16. [Proximal tibial osteotomy for osteoarthritis of the knee with varus deformity].
Baur W; Hönle W; Schuh A
Oper Orthop Traumatol; 2005 Sep; 17(3):326-44. PubMed ID: 16132254
[TBL] [Abstract][Full Text] [Related]
17. 'Fine-tuned' correction of tibial slope with a temporary external fixator in opening wedge high-tibial osteotomy.
Jung KA; Kim SJ; Lee SC; Song MB; Yoon KH
Knee Surg Sports Traumatol Arthrosc; 2008 Mar; 16(3):305-10. PubMed ID: 18183371
[TBL] [Abstract][Full Text] [Related]
18. Comparison of sagittal and frontal plane alignment after open- and closed-wedge osteotomy: a matched-pair analysis.
Schaefer TK; Majewski M; Hirschmann MT; Friederich NF
J Int Med Res; 2008; 36(5):1085-93. PubMed ID: 18831905
[TBL] [Abstract][Full Text] [Related]
19. Medial open wedge high tibial osteotomy: the effect of the cortical hinge on posterior tibial slope.
Wang JH; Bae JH; Lim HC; Shon WY; Kim CW; Cho JW
Am J Sports Med; 2009 Dec; 37(12):2411-8. PubMed ID: 19684296
[TBL] [Abstract][Full Text] [Related]
20. Comparative analysis of osteotomy accuracy between the conventional and devised technique using a protective cutting system in medial open-wedge high tibial osteotomy.
Lee YS; Moon GH
J Orthop Sci; 2015 Jan; 20(1):129-36. PubMed ID: 25346318
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]