These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 12774576)

  • 1. The impact of surface mount FeedThru varistors on medical circuit design.
    Demcko R
    Med Device Technol; 2003 May; 14(4):30-1. PubMed ID: 12774576
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effective electromagnetic interference shielding for electronic equipment.
    Sheedy B
    Med Device Technol; 2003 Nov; 14(9):39-41. PubMed ID: 14682024
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Solving electromagnetic compatibility problems in medical equipment.
    Kirk S
    Med Device Technol; 1992; 3(1):27-30. PubMed ID: 10171584
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Designing medical equipment for electromagnetic compatibility.
    Kirk S
    Med Device Technol; 1992 May; 3(4):42-9. PubMed ID: 10147988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Circuit board design for good electromagnetic compatibility performance.
    Bearpark J
    Med Device Technol; 2005 Oct; 16(8):26-7, 29. PubMed ID: 16355968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Best practice for electromagnetic compatibility.
    Med Device Technol; 2005 Jun; 16(5):56-7. PubMed ID: 15984548
    [No Abstract]   [Full Text] [Related]  

  • 7. [Study on selection of the EMC test system of medical electrical equipment].
    Wang W
    Zhongguo Yi Liao Qi Xie Za Zhi; 2011 Nov; 35(6):449-52. PubMed ID: 22379776
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Meeting the requirements for medical equipment EMC: a test house perspective.
    Gubisch RW
    Biomed Instrum Technol; 1999; 33(2):132-7. PubMed ID: 10194566
    [No Abstract]   [Full Text] [Related]  

  • 9. [A device for the display of the distribution of the high-frequency electromagnetic fields used in medicine].
    Masychev SI
    Med Tekh; 1996; (3):46-8. PubMed ID: 8926839
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thin-film passive microcomponents for improved circuit performance.
    Christian KD
    Med Device Technol; 2004 Nov; 15(9):35-7. PubMed ID: 16231787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation protection and shielding design--strengthening the link.
    Hobson J; Cooper A
    Radiat Prot Dosimetry; 2005; 115(1-4):251-3. PubMed ID: 16381722
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Experience in developing devices for medical use exemplified by the electronic stethophonoendoscope].
    Andreev AA; LeshchinskiÄ­ LA
    Med Tekh; 1996; (3):13-5. PubMed ID: 8926840
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The electronic neutron/photon dosemeter PTB DOS-2002.
    Luszik-Bhadra M; Wendt W; Weierganz M
    Radiat Prot Dosimetry; 2004; 110(1-4):291-5. PubMed ID: 15353661
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Protection against electromagnetic interference (EMI) for sensitive medical devices.
    Herbert L
    Health Estate J; 1997 Apr; 51(3):2-5. PubMed ID: 10169408
    [No Abstract]   [Full Text] [Related]  

  • 15. US contributions to international standards for medical electrical equipment.
    Ibbott GS
    J Am Coll Radiol; 2012 Mar; 9(3):218-20. PubMed ID: 22386172
    [No Abstract]   [Full Text] [Related]  

  • 16. Interference by new-generation mobile phones on critical care medical equipment.
    van Lieshout EJ; van der Veer SN; Hensbroek R; Korevaar JC; Vroom MB; Schultz MJ
    Crit Care; 2007; 11(5):R98. PubMed ID: 17822524
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safe introduction of in-hospital wireless LAN.
    Hanada E; Hoshino Y; Kudou T
    Stud Health Technol Inform; 2004; 107(Pt 2):1426-9. PubMed ID: 15361050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of pentaphasic pulse sequence as an impedance sensor on standard electrocardiographic recordings.
    Mortazavi S; Park E; Florio J; Poore J; Bornzin G; Levine PA; Sholder J
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1678-81. PubMed ID: 8945023
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electromagnetic interference with electronic medical equipment induced by automatic conveyance systems.
    Hanada E; Watanabe Y; Nose Y
    J Med Syst; 2000 Feb; 24(1):11-20. PubMed ID: 10782439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Overview of active personal dosemeters for individual monitoring in the European Union.
    Ginjaume M; Bolognese-Milsztajn T; Luszik-Bhadra M; Vanhavere F; Wahl W; Weeks A
    Radiat Prot Dosimetry; 2007; 125(1-4):261-6. PubMed ID: 16980319
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.