These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 1277940)

  • 21. ECHO and magnetic resonance imaging in a patient with high bleeding risk and ventricular perforation: a case report and literature review.
    Truscelli G; Galea N; Barillà F; Pellicori P; Toscano F; Gaudio C; Carbone I; Torromeo C
    Eur Rev Med Pharmacol Sci; 2011 Jun; 15(6):721-4. PubMed ID: 21796878
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Postpacemaker implant pericarditis: incidence and outcomes with active-fixation leads.
    Sivakumaran S; Irwin ME; Gulamhusein SS; Senaratne MP
    Pacing Clin Electrophysiol; 2002 May; 25(5):833-7. PubMed ID: 12049377
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Severe pacemaker lead perforation detected by an automatic home-monitoring system.
    Spencker S; Mueller D; Marek A; Zabel M
    Eur Heart J; 2007 Jun; 28(12):1432. PubMed ID: 17267455
    [No Abstract]   [Full Text] [Related]  

  • 24. Late perforation of the heart, pericardium, and diaphragm by an active-fixation ventricular lead.
    Akyol A; Aydin A; Erdinler I; Oguz E
    Pacing Clin Electrophysiol; 2005 Apr; 28(4):350-1. PubMed ID: 15826277
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An unusual presentation of delayed cardiac perforation caused by atrial screw-in lead.
    Velavan P; Chauhan A
    Heart; 2003 Apr; 89(4):364. PubMed ID: 12639855
    [No Abstract]   [Full Text] [Related]  

  • 26. [Extraction of tricuspid valve tissue and myocardium as a complication of transvenous cardiac pacing (author's transl)].
    Köhler F; Schmitt CG; Ellringmann U
    Thoraxchir Vask Chir; 1977 Apr; 25(2):97-100. PubMed ID: 300918
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Roentgenographic findings in patients with pacemakers (author's transl)].
    du Mesnil de Rochemont W
    Rontgenblatter; 1976 Jan; 29(1):5-12. PubMed ID: 1251123
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Delayed complications following pacemaker implantation.
    Ellenbogen KA; Wood MA; Shepard RK
    Pacing Clin Electrophysiol; 2002 Aug; 25(8):1155-8. PubMed ID: 12358163
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Hiccup as a result of late lead perforation: report of two cases and review of the literature.
    Celik T; Kose S; Bugan B; Iyisoy A; Akgun V; Cingoz F
    Europace; 2009 Jul; 11(7):963-5. PubMed ID: 19359331
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Delayed cardiac perforation due to migrating pacemaker lead.
    Oikonomou A; Foutzitzi S; Prassopoulos P
    CMAJ; 2010 Jun; 182(9):E379. PubMed ID: 20403890
    [No Abstract]   [Full Text] [Related]  

  • 31. Clinical evaluation of myocardial perforation as a complication of permanent transvenous pacemakers.
    Rubenfire M; Anbe DT; Drake EH; Ormond RS
    Chest; 1973 Feb; 63(2):185-8. PubMed ID: 4688064
    [No Abstract]   [Full Text] [Related]  

  • 32. Beware of the coronary arteries with implantable cardiac electronic devices.
    Barold SS; Pang BJ; Mond HG
    Herzschrittmacherther Elektrophysiol; 2017 Sep; 28(3):317-319. PubMed ID: 28819689
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Removal of myocardial fragment containing a pacemaker electrode.
    Furman S
    Ann Thorac Surg; 1975 Jun; 19(6):716-8. PubMed ID: 1138648
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Response.
    Elmouchi D
    Pacing Clin Electrophysiol; 2014 May; 37(5):658-9. PubMed ID: 24645895
    [No Abstract]   [Full Text] [Related]  

  • 35. The wayward pacemaker electrode.
    Wittenstein GJ
    Acta Chir Belg; 1978; 77(6):381-7. PubMed ID: 749481
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium.
    Mase H; Tamura K; Hiromoto A; Hotta M; Hotomi S; Togashi M; Fukuda Y; Yajima T; Nitta T; Tanaka S; Sugisaki Y
    J Nippon Med Sch; 2005 Feb; 72(1):52-9. PubMed ID: 15834208
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pneumopericardium and pneumothorax contralateral to venous access site after permanent pacemaker implantation.
    Srivathsan K; Byrne RA; Appleton CP; Scott LR
    Europace; 2003 Oct; 5(4):361-3. PubMed ID: 14753631
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Left hemothorax: a presentation of a late ventricular perforation caused by an active fixation pacing lead.
    Bohora S; Unnikrishnan M; Ajit Kumar VK; Nayyar S; Tharakan J
    Int J Cardiol; 2010 Jun; 141(3):e43-6. PubMed ID: 19157597
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Postpacemaker implant pericarditis: incidence and outcomes with active-fixation leads.
    Parsonnet V
    Pacing Clin Electrophysiol; 2002 Dec; 25(12):1795; author reply 1795. PubMed ID: 12520690
    [No Abstract]   [Full Text] [Related]  

  • 40. Device lead screw tip induced pericarditis--a subtle complication in need of wider recognition.
    Panaich SS; Cardozo S; Jacob S; Afonso L
    Int J Cardiol; 2013 Aug; 167(3):e76-7. PubMed ID: 23642589
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.