  • 21. Increased Resistance to Flow and Ventilator Failure Secondary to Faulty CO2 Absorbent Insert Not Detected During Automated Anesthesia Machine Check: A Case Report.
    Moreno-Duarte I; Montenegro J; Balonov K; Schumann R
    A A Case Rep; 2017 Apr; 8(8):192-196. PubMed ID: 28151764
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pressure monitoring hose causes leak in anesthesia breathing circuit.
    Lee O; Sommer RM
    Anesth Analg; 1991 Sep; 73(3):365. PubMed ID: 1867440
    [No Abstract]   [Full Text] [Related]  

  • 23. Don't let the Bain take the blame.
    Uncles DR; Parke TJ
    Can J Anaesth; 1994 Oct; 41(10):1015. PubMed ID: 8001199
    [No Abstract]   [Full Text] [Related]  

  • 24. An uncommon leak in the anesthesia breathing circuit.
    Bromley HR; Tuorinsky S
    Anesth Analg; 1997 Sep; 85(3):707. PubMed ID: 9296441
    [No Abstract]   [Full Text] [Related]  

  • 25. Spontaneous breathing of heliox using a semi-closed circuit: a bench study.
    Roubík K; Zazula R; Strnadová A; Zábrodský V; Spálený A; Müller M; Chlumský J; Tyll T
    Int J Artif Organs; 2012 Jun; 35(6):466-70. PubMed ID: 22466996
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accidental switch-off of an anaesthetic machine.
    Ronald AL
    Anaesthesia; 1999 May; 54(5):504-5. PubMed ID: 10995167
    [No Abstract]   [Full Text] [Related]  

  • 27. Displaced adjustable pressure limiting valve leaflet leading to partial expiratory obstruction in a cat.
    West E; Halil J
    Vet Anaesth Analg; 2019 Jan; 46(1):143-145. PubMed ID: 30528343
    [No Abstract]   [Full Text] [Related]  

  • 28. Bain circuit adapter fault.
    Allen P
    Anaesth Intensive Care; 2000 Jun; 28(3):333. PubMed ID: 10853223
    [No Abstract]   [Full Text] [Related]  

  • 29. Anesthetic breathing circuit obstruction mimicking severe bronchospasm: an unusual manufacturing defect.
    Yang CH; Chen KH; Lee YE; Lin CR
    Acta Anaesthesiol Taiwan; 2012 Mar; 50(1):35-7. PubMed ID: 22500912
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Failure to ventilate.
    Anderson TY
    Anaesth Intensive Care; 1993 Dec; 21(6):898. PubMed ID: 8122767
    [No Abstract]   [Full Text] [Related]  

  • 31. Breathing system malfunction and the 'extra circuit'.
    Sanehi O
    Anaesthesia; 2003 Nov; 58(11):1131-2; discussion 1132. PubMed ID: 14616614
    [No Abstract]   [Full Text] [Related]  

  • 32. A cause of breathing system leak during closed circuit anesthesia.
    Ferderbar PJ; Kettler RE; Jablonski J; Sportiello R
    Anesthesiology; 1986 Dec; 65(6):661-3. PubMed ID: 3789438
    [No Abstract]   [Full Text] [Related]  

  • 33. Kinking of disposable anaesthetic circuits.
    Vohra SB
    Anaesthesia; 2006 Jul; 61(7):721. PubMed ID: 16792633
    [No Abstract]   [Full Text] [Related]  

  • 34. An unusual anesthesia machine leak.
    Mark D
    J Clin Anesth; 2000 Feb; 12(1):87. PubMed ID: 10785878
    [No Abstract]   [Full Text] [Related]  

  • 35. [Halothane at a liquid state in the ventilatory circuit: a rare incident of anesthesia].
    Laoutid J; Moujahid A; Hachimi MA; Hanafi SM; Mahmoudi A
    Ann Fr Anesth Reanim; 2014 Mar; 33(3):190-2. PubMed ID: 24565943
    [No Abstract]   [Full Text] [Related]  

  • 36. A critical incident: manufacturing or human error?
    Mills SJ
    Anaesthesia; 2002 Jan; 57(1):94-5. PubMed ID: 11843759
    [No Abstract]   [Full Text] [Related]  

  • 37. An unusual cause of anesthesia circuit blockade by SODASORB PRE-PAK.
    Ramarapu S; Ramakrishnan U
    Anesth Analg; 2012 Aug; 115(2):477; discussion 477-8. PubMed ID: 22826525
    [No Abstract]   [Full Text] [Related]  

  • 38. Hypercapnia related to a faulty adult co-axial breathing circuit.
    Jellish WS; Nolan T; Kleinman B
    Anesth Analg; 2001 Oct; 93(4):973-4, table of contents. PubMed ID: 11574367
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient.
    Rajkumar A; Bajekal R
    J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451
    [No Abstract]   [Full Text] [Related]  

  • 40. Detection of faulty CO2 absorber by capnography.
    Riley RH; Harris LA; Hale AP; Dockar G
    Anaesth Intensive Care; 1992 May; 20(2):246. PubMed ID: 1595865
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]