21. Increased Resistance to Flow and Ventilator Failure Secondary to Faulty CO2 Absorbent Insert Not Detected During Automated Anesthesia Machine Check: A Case Report. Moreno-Duarte I; Montenegro J; Balonov K; Schumann R A A Case Rep; 2017 Apr; 8(8):192-196. PubMed ID: 28151764 [TBL] [Abstract][Full Text] [Related]
22. Pressure monitoring hose causes leak in anesthesia breathing circuit. Lee O; Sommer RM Anesth Analg; 1991 Sep; 73(3):365. PubMed ID: 1867440 [No Abstract] [Full Text] [Related]
23. Don't let the Bain take the blame. Uncles DR; Parke TJ Can J Anaesth; 1994 Oct; 41(10):1015. PubMed ID: 8001199 [No Abstract] [Full Text] [Related]
24. An uncommon leak in the anesthesia breathing circuit. Bromley HR; Tuorinsky S Anesth Analg; 1997 Sep; 85(3):707. PubMed ID: 9296441 [No Abstract] [Full Text] [Related]
25. Spontaneous breathing of heliox using a semi-closed circuit: a bench study. Roubík K; Zazula R; Strnadová A; Zábrodský V; Spálený A; Müller M; Chlumský J; Tyll T Int J Artif Organs; 2012 Jun; 35(6):466-70. PubMed ID: 22466996 [TBL] [Abstract][Full Text] [Related]
26. Accidental switch-off of an anaesthetic machine. Ronald AL Anaesthesia; 1999 May; 54(5):504-5. PubMed ID: 10995167 [No Abstract] [Full Text] [Related]
27. Displaced adjustable pressure limiting valve leaflet leading to partial expiratory obstruction in a cat. West E; Halil J Vet Anaesth Analg; 2019 Jan; 46(1):143-145. PubMed ID: 30528343 [No Abstract] [Full Text] [Related]
34. An unusual anesthesia machine leak. Mark D J Clin Anesth; 2000 Feb; 12(1):87. PubMed ID: 10785878 [No Abstract] [Full Text] [Related]
35. [Halothane at a liquid state in the ventilatory circuit: a rare incident of anesthesia]. Laoutid J; Moujahid A; Hachimi MA; Hanafi SM; Mahmoudi A Ann Fr Anesth Reanim; 2014 Mar; 33(3):190-2. PubMed ID: 24565943 [No Abstract] [Full Text] [Related]
36. A critical incident: manufacturing or human error? Mills SJ Anaesthesia; 2002 Jan; 57(1):94-5. PubMed ID: 11843759 [No Abstract] [Full Text] [Related]
37. An unusual cause of anesthesia circuit blockade by SODASORB PRE-PAK. Ramarapu S; Ramakrishnan U Anesth Analg; 2012 Aug; 115(2):477; discussion 477-8. PubMed ID: 22826525 [No Abstract] [Full Text] [Related]
38. Hypercapnia related to a faulty adult co-axial breathing circuit. Jellish WS; Nolan T; Kleinman B Anesth Analg; 2001 Oct; 93(4):973-4, table of contents. PubMed ID: 11574367 [TBL] [Abstract][Full Text] [Related]
39. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient. Rajkumar A; Bajekal R J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451 [No Abstract] [Full Text] [Related]
40. Detection of faulty CO2 absorber by capnography. Riley RH; Harris LA; Hale AP; Dockar G Anaesth Intensive Care; 1992 May; 20(2):246. PubMed ID: 1595865 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]