  • 1. Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker.
    van Krieken FM; Perrins JP; Sigmund M
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1815-20. PubMed ID: 1279553
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: the importance of individual sensor programming.
    Lau CP; Leung SK; Lee IS
    Pacing Clin Electrophysiol; 1996 Jul; 19(7):1021-5. PubMed ID: 8823827
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical observations with a dual sensor rate adaptive single chamber pacemaker.
    Provenier F; van Acker R; Backers J; van Wassenhove E; de Meyer V; Jordaens L
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1821-5. PubMed ID: 1279554
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual sensor VVIR mode pacing: is it worth it?
    Sulke N; Tan K; Kamalvand K; Bostock J; Bucknall C
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1560-7. PubMed ID: 8946451
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm.
    Lau CP; Leung SK; Guerola M; Crijns HJ
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1672-7. PubMed ID: 8945022
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers.
    Lau CP; Tai YT; Fong PC; Li JP; Chung FL
    Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1504-14. PubMed ID: 1383962
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers.
    Leung SK; Lau CP; Tang MO
    Pacing Clin Electrophysiol; 1998 Jan; 21(1 Pt 1):35-41. PubMed ID: 9474646
    [TBL] [Abstract][Full Text] [Related]  

  • 8. One-year follow-up of automatic adaptation of the rate response algorithm of the QT sensing, rate adaptive pacemaker.
    Baig MW; Boute W; Begemann M; Perrins EJ
    Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 1):1598-605. PubMed ID: 1721149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multicenter clinical evaluation of a new SSIR pacemaker.
    Bongiorni MG; Soldati E; Arena G; de Simone L; Capucci A; Galli R; Parlapiano M; Cazzin R; Moracchini P; Leonardi C
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1798-803. PubMed ID: 1279550
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is accurate rate response programming necessary?
    Sulke N; Dritsas A; Chambers J; Sowton E
    Pacing Clin Electrophysiol; 1990 Aug; 13(8):1031-44. PubMed ID: 1697950
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Initial clinical experience with a single pass VDDR pacing system.
    Lau CP; Tai YT; Li JP; Chung FL; Sung S; Yamamoto A
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1894-900. PubMed ID: 1279567
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of a rate responsive accelerometer-based pacemaker with autocalibration during standardized exercise and recovery.
    Garrigue S; Gentilini C; Hofgartner F; Mouton E; Rousseau A; Clementy J;
    Pacing Clin Electrophysiol; 2002 Jun; 25(6):883-7. PubMed ID: 12137339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Usefulness and adequacy of sensor data storage and retrieval for rate response simulation.
    Mahaux V; Waleffe A; Kulbertus H
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 1):1688-95. PubMed ID: 1279536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical interest of a sensor driven algorithm limiting ventricular pacing rate during supraventricular tachycardia in dual chamber pacing.
    Mahaux V; Verboven Y; Waleffe A; Kulbertus H
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1862-6. PubMed ID: 1279561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial clinical experience with rate adaptive cardiac pacing using two sensors simultaneously.
    Landman MA; Senden PJ; van Rooijen H; van Hemel NM
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 1):1615-22. PubMed ID: 1704514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing.
    Leung SK; Lau CP; Wu CW; Leung WH; Tai YT; Lee I; Chow YH
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1920-7. PubMed ID: 7845792
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new motion responsive pacemaker: first clinical experience with an acceleration sensor pacemaker.
    Borst U; Siekmeyer G; Maisch B; Kaye S
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1809-14. PubMed ID: 1279552
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Apparent P wave undersensing in a DDD pacemaker post exercise.
    van Gelder BM; van Mechelen R; den Dulk K; el Gamal MI
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 1):1651-6. PubMed ID: 1279530
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.
    Kantharia BK; Freedman RA; Hoekenga D; Tomassoni G; Worley S; Sorrentino R; Steinhaus D; Wolkowicz JM; Syed ZA;
    Europace; 2007 Nov; 9(11):1024-30. PubMed ID: 17913697
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Initial experience with mode switching in a dual sensor, dual chamber pacemaker in patients with paroxysmal atrial tachyarrhythmias.
    den Dulk K; Dijkman B; Pieterse M; Wellens H
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1900-7. PubMed ID: 7845789
    [TBL] [Abstract][Full Text] [Related]  