9. Rate responsive pacing with a minute ventilation sensing pacemaker during pregnancy and delivery. Lau CP; Lee CP; Wong CK; Cheng CH; Leung WH Pacing Clin Electrophysiol; 1990 Feb; 13(2):158-63. PubMed ID: 1689831 [TBL] [Abstract][Full Text] [Related]
10. Rate responsive pacing using a minute ventilation sensor. Mond H; Strathmore N; Kertes P; Hunt D; Baker G Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1866-74. PubMed ID: 2463560 [TBL] [Abstract][Full Text] [Related]
11. First derivative of right ventricular pressure, dP/dt, as a sensor for a rate adaptive VVI pacemaker: initial experience. Ovsyshcher I; Guetta V; Bondy C; Porath A Pacing Clin Electrophysiol; 1992 Feb; 15(2):211-8. PubMed ID: 1372420 [TBL] [Abstract][Full Text] [Related]
12. Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker. van Krieken FM; Perrins JP; Sigmund M Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1815-20. PubMed ID: 1279553 [TBL] [Abstract][Full Text] [Related]
13. The effects of rate responsive pacing on exercise performance in the postoperative univentricular heart. Paridon SM; Karpawich PP; Pinsky WW Pacing Clin Electrophysiol; 1993 Jun; 16(6):1256-62. PubMed ID: 7686655 [TBL] [Abstract][Full Text] [Related]
14. Follow-up of a respiratory rate modulated pacemaker. Santomauro M; Fazio S; Ferraro S; Maddalena G; Papaccioli G; Pappone C; Saccà L; Chiariello M Pacing Clin Electrophysiol; 1992 Jan; 15(1):17-21. PubMed ID: 1370995 [TBL] [Abstract][Full Text] [Related]
15. Sensor-driven rate smoothing in a DDDR pacemaker. Higano ST; Hayes DL; Eisinger G Pacing Clin Electrophysiol; 1989 Jun; 12(6):922-9. PubMed ID: 2472619 [TBL] [Abstract][Full Text] [Related]
16. Automatic adaptation of the basic pacing rate in response to minute ventilation. Chorum French Investigational Group. Limousin M; Pioger G; Bonnet JL; Geroux L Pacing Clin Electrophysiol; 1998 Jul; 21(7):1405-9. PubMed ID: 9670184 [TBL] [Abstract][Full Text] [Related]
17. Initial clinical experience with a new dual sensor SSIR pacemaker controlled by body activity and minute ventilation. Alt E; Combs W; Fotuhi P; Bambl E; Wahlstrand J; Willhaus R Pacing Clin Electrophysiol; 1995 Aug; 18(8):1487-95. PubMed ID: 7479170 [TBL] [Abstract][Full Text] [Related]
18. Clinical observations with a dual sensor rate adaptive single chamber pacemaker. Provenier F; van Acker R; Backers J; van Wassenhove E; de Meyer V; Jordaens L Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1821-5. PubMed ID: 1279554 [TBL] [Abstract][Full Text] [Related]
19. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers. Lau CP; Tai YT; Fong PC; Li JP; Chung FL Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1504-14. PubMed ID: 1383962 [TBL] [Abstract][Full Text] [Related]
20. Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm. Lau CP; Leung SK; Guerola M; Crijns HJ Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1672-7. PubMed ID: 8945022 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]