These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 1279563)

  • 1. Feasibility of using intracardiac impedance measurements for capture detection.
    Alt E; Kriegler C; Fotuhi P; Willhaus R; Combs W; Heinz M; Hayes D
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1873-9. PubMed ID: 1279563
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity.
    Schwaab B; Fröhlig G; Schwerdt H; Heisel A; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2055-63. PubMed ID: 9826856
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reduction of pacing output coupling capacitance for sensing the evoked response.
    Sperzel J; Neuzner J; Schwarz T; Zhu Q; König A; Kay GN
    Pacing Clin Electrophysiol; 2001 Sep; 24(9 Pt 1):1377-82. PubMed ID: 11584460
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Algorithm for ventricular capture verification based on the mechanical evoked response.
    Yaacoby E; Akselrod S; Eldar M; Glikson M
    Med Biol Eng Comput; 2005 Jul; 43(4):511-5. PubMed ID: 16255434
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity.
    Schuchert A; Meinertz T;
    Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1234-9. PubMed ID: 11523609
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automatic management of atrial and ventricular stimulation in a contemporary unselected population of pacemaker recipients: the ESSENTIAL Registry.
    Biffi M; Bertini M; Saporito D; Belotti G; Quartieri F; Piancastelli M; Pucci A; Boggian G; Mazzocca GF; Giorgi D; Diotallevi P; Diemberger I; Martignani C; Pancaldi S; Ziacchi M; Marcantoni L; Toselli T; Attala S; Iori M; Bottoni N; Argnani S; Tomasi C; Sassone B; Boriani G
    Europace; 2016 Oct; 18(10):1551-1560. PubMed ID: 27305923
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chronic ventricular pacing using an output amplitude of 1.0 volt.
    Schwaab B; Schwerdt H; Heisel A; Fröhlig G; Schieffer H
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2171-8. PubMed ID: 9309740
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new pacemaker algorithm for continuous capture verification and automatic threshold determination: elimination of pacemaker afterpotential utilizing a triphasic charge balancing system.
    Feld GK; Love CJ; Camerlo J; Marsella R
    Pacing Clin Electrophysiol; 1992 Feb; 15(2):171-8. PubMed ID: 1372416
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Uni- and bipolar pacing threshold measurements with capturecontrol, a new automatic pacemaker function for capture verification. Comparison of the automatic and the manual pacing threshold measurement.
    Schuchert A; Meinertz T
    Cardiology; 1999; 92(3):210-3. PubMed ID: 10754353
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Adjustment of the evoked response sensitivity after hospital discharge in pacemaker patients with automatic ventricular threshold tracking activated.
    Schuchert A; Ventura R; Meinertz T;
    Pacing Clin Electrophysiol; 2001 Feb; 24(2):212-6. PubMed ID: 11270702
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of automatic threshold capture on pulse generator longevity.
    Chen RH; Chen KP; Wang FZ; Hua W; Zhang S
    Chin Med J (Engl); 2006 Jun; 119(11):925-9. PubMed ID: 16780772
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of pentaphasic pulse sequence as an impedance sensor on standard electrocardiographic recordings.
    Mortazavi S; Park E; Florio J; Poore J; Bornzin G; Levine PA; Sholder J
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1678-81. PubMed ID: 8945023
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Energy parameters in cardiac pacing should be abandoned.
    Barold SS; Stokes K; Byrd CL; McVenes R
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 1):112-21. PubMed ID: 9121955
    [No Abstract]   [Full Text] [Related]  

  • 15. Autocapture enhancements: unipolar and bipolar lead compatibility and bipolar pacing capability on bipolar leads.
    Binner L; Messenger J; Sperzel J; Bondke H; Vandekerckhove Y; Poore J; Scheiner J; Berkhof M; Park E; Holmström N; Bornzin GA
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):221-4. PubMed ID: 12687816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impedance of pacemaker leads: correlation of different methods.
    Siegmund JB; Wilson JH; Lattner SE; Granneman K; Johnson R
    Pacing Clin Electrophysiol; 1996 Jan; 19(1):90-4. PubMed ID: 8848383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability and variability of impedance measured by real-time telemetry.
    Schuchert A; Cappato R; Kuck KH; Meinertz T
    Pacing Clin Electrophysiol; 1996 Mar; 19(3):265-71. PubMed ID: 8657585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of electrical characteristics between a steroid-eluting single-pass VDD lead and a standard steroid-eluting ventricular lead. Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1997 Jul; 20(7):1787-9. PubMed ID: 9249832
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An algorithm for automatic measurement of stimulation thresholds: clinical performance and preliminary results.
    Danilovic D; Ohm OJ; Stroebel J; Breivik K; Hoff PI; Markowitz T
    Pacing Clin Electrophysiol; 1998 May; 21(5):1058-68. PubMed ID: 9604237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
    Danilovic D; Ohm OJ
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):567-87. PubMed ID: 10234710
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.