These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
197 related articles for article (PubMed ID: 12803290)
1. On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation. Fridolin I; Lindberg LG Med Biol Eng Comput; 2003 May; 41(3):263-70. PubMed ID: 12803290 [TBL] [Abstract][Full Text] [Related]
2. On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description. Fridolin I; Magnusson M; Lindberg LG Int J Artif Organs; 2002 Aug; 25(8):748-61. PubMed ID: 12296459 [TBL] [Abstract][Full Text] [Related]
3. Optical dialysis adequacy sensor: wavelength dependence of the ultra violet absorbance in the spent dialysate to the removed solutes. Jerotskaja J; Lauri K; Tanner R; Luman M; Fridolin I Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2960-3. PubMed ID: 18002616 [TBL] [Abstract][Full Text] [Related]
4. HPLC study of uremic fluids related to optical dialysis adequacy monitoring. Lauri K; Tanner R; Jerotskaja J; Luman M; Fridolin I Int J Artif Organs; 2010 Feb; 33(2):96-104. PubMed ID: 20306436 [TBL] [Abstract][Full Text] [Related]
5. Optical Estimation of Beta 2 Microglobulin during Hemodiafiltration – Does It Work? Uhlin F; Holmar J; Yngman-Uhlin P; Fernström A; Fridolin I Blood Purif; 2015; 40(2):113-9. PubMed ID: 26159848 [TBL] [Abstract][Full Text] [Related]
6. Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance. Uhlin F; Fridolin I; Magnusson M; Lindberg LG Nephrol Dial Transplant; 2006 Aug; 21(8):2225-31. PubMed ID: 16611681 [TBL] [Abstract][Full Text] [Related]
7. Uric acid is the major determinant of absorbance in spent dialysate allowing spectrophotometric evaluation of dialysis dose. Donadio C; Calia D; Ghimenti S; Onor M; Colombini E; Fuoco R; Di Francesco F J Nephrol; 2014 Jun; 27(3):331-7. PubMed ID: 24535999 [TBL] [Abstract][Full Text] [Related]
8. Estimating total urea removal and protein catabolic rate by monitoring UV absorbance in spent dialysate. Uhlin F; Fridolin I; Lindberg LG; Magnusson M Nephrol Dial Transplant; 2005 Nov; 20(11):2458-64. PubMed ID: 16077147 [TBL] [Abstract][Full Text] [Related]
9. Optical dialysis adequacy sensor: contribution of chromophores to the ultra violet absorbance in the spent dialysate. Lauri K; Tanner R; Luman M; Jerotskaja J; Fridolin I Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():807-10. PubMed ID: 17945602 [TBL] [Abstract][Full Text] [Related]
10. Urea Rebound Assessment Based on UV Absorbance in Spent Dialysate. Tomson R; Uhlin F; Fridolin I ASAIO J; 2014; 60(4):459-65. PubMed ID: 24814831 [TBL] [Abstract][Full Text] [Related]
11. Optical measurement of creatinine in spent dialysate. Tomson R; Fridolin I; Uhlin F; Holmar J; Lauri K; Luman M Clin Nephrol; 2013 Feb; 79(2):107-17. PubMed ID: 23110769 [TBL] [Abstract][Full Text] [Related]
12. Effects of protein leakage on online monitoring of ultraviolet absorbance in spent dialysate. Yamamoto K; Hirakawa S; Murakami J; Akiba T; Mineshima M J Artif Organs; 2016 Sep; 19(3):278-82. PubMed ID: 27034069 [TBL] [Abstract][Full Text] [Related]
13. Do only small uremic toxins, chromophores, contribute to the online dialysis dose monitoring by UV absorbance? Arund J; Tanner R; Uhlin F; Fridolin I Toxins (Basel); 2012 Oct; 4(10):849-61. PubMed ID: 23162701 [TBL] [Abstract][Full Text] [Related]
14. Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate. Uhlin F; Fridolin I; Lindberg LG; Magnusson M Am J Kidney Dis; 2003 May; 41(5):1026-36. PubMed ID: 12722037 [TBL] [Abstract][Full Text] [Related]
15. Complementary parameter for dialysis monitoring based on UV absorbance. Uhlin F; Pettersson J; Fernström A; Lindberg LG Hemodial Int; 2009 Oct; 13(4):492-7. PubMed ID: 19758302 [TBL] [Abstract][Full Text] [Related]
16. Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement. Argilés A; Ficheux A; Thomas M; Bosc JY; Kerr PG; Lorho R; Flavier JL; Stec F; Adelé C; Leblanc M; Garred LJ; Canaud B; Mion H; Mion CM Kidney Int; 1997 Aug; 52(2):530-7. PubMed ID: 9264013 [TBL] [Abstract][Full Text] [Related]
17. Optical method for cardiovascular risk marker uric acid removal assessment during dialysis. Holmar J; Fridolin I; Uhlin F; Lauri K; Luman M ScientificWorldJournal; 2012; 2012():506486. PubMed ID: 22701094 [TBL] [Abstract][Full Text] [Related]
18. The Removal of β2-Microglobulin in Spent Dialysate Cannot Be Monitored by Spectrophotometric Analysis. Donadio C; Calia D; Ghimenti S; Onor M; Colombini E; Fuoco R; Di Francesco F Blood Purif; 2015; 40(2):109-12. PubMed ID: 26183959 [No Abstract] [Full Text] [Related]
19. Removal of Urea, β2-Microglobulin, and Indoxyl Sulfate Assessed by Absorbance and Fluorescence in the Spent Dialysate During Hemodialysis. Lauri K; Arund J; Holmar J; Tanner R; Kalle S; Luman M; Fridolin I ASAIO J; 2020 Jun; 66(6):698-705. PubMed ID: 31425267 [TBL] [Abstract][Full Text] [Related]
20. Lean body mass assessment based on UV absorbance in spent dialysate and dual-energy x-ray absorptiometry. Tomson R; Fridolin I; Luman M Int J Artif Organs; 2015 Jun; 38(6):311-5. PubMed ID: 26109264 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]