These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 12812325)

  • 1. An evaluation of the effectiveness of the patellar tendon bar in the trans-tibial patellar-tendon-bearing prosthesis socket.
    Kim WD; Lim D; Hong KS
    Prosthet Orthot Int; 2003 Apr; 27(1):23-35. PubMed ID: 12812325
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the effects of patellar tendon bearing and total surface bearing sockets on prosthetic fitting and rehabilitation.
    Yiğiter K; Sener G; Bayar K
    Prosthet Orthot Int; 2002 Dec; 26(3):206-12. PubMed ID: 12562067
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The patellar tendon bar! Is it a necessary feature?
    Abu Osman NA; Spence WD; Solomonidis SE; Paul JP; Weir AM
    Med Eng Phys; 2010 Sep; 32(7):760-5. PubMed ID: 20678997
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Patellar tendon morphology in trans-tibial amputees utilizing a prosthesis with a patellar-tendon-bearing feature.
    Ho KY; Harty M; Kellogg J; Teter K; Lee SP; Chang YJ; Bashford G
    Sci Rep; 2019 Nov; 9(1):16392. PubMed ID: 31704989
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis.
    Narita H; Yokogushi K; Shii S; Kakizawa M; Nosaka T
    Prosthet Orthot Int; 1997 Dec; 21(3):175-8. PubMed ID: 9453088
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of alignment perturbations in a trans-tibial prosthesis user: A pilot study.
    Courtney A; Orendurff MS; Buis A
    J Rehabil Med; 2016 Apr; 48(4):396-401. PubMed ID: 26983760
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee.
    Convery P; Buis AW
    Prosthet Orthot Int; 1998 Dec; 22(3):193-8. PubMed ID: 9881607
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interface pressure profile analysis for patellar tendon-bearing socket and hydrostatic socket.
    Moo EK; Osman NA; Pingguan-Murphy B; Abas WA; Spence WD; Solomonidis SE
    Acta Bioeng Biomech; 2009; 11(4):37-43. PubMed ID: 20405814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.
    Convery P; Buis AW
    Prosthet Orthot Int; 1999 Aug; 23(2):107-12. PubMed ID: 10493137
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gait, cost and time implications for changing from PTB to ICEX sockets.
    Datta D; Harris I; Heller B; Howitt J; Martin R
    Prosthet Orthot Int; 2004 Aug; 28(2):115-20. PubMed ID: 15382805
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The rotational axis of the tibia and relationship to the tibial torsion in varus osteoarthritic knee.
    Chotanaphuti T; Srisawasdi R; Rattanaprichavej P; Laoruengthana A
    J Med Assoc Thai; 2012 Oct; 95 Suppl 10():S6-11. PubMed ID: 23451431
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Easy Technique for Radiographic Evaluation of Stump-socket Fit in Below-knee Amputees.
    Tsur A
    Ortop Traumatol Rehabil; 2019 Feb; 21(1):57-63. PubMed ID: 31019111
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new alignment jig for quantification and prescription of three-dimensional alignment for the patellar-tendon-bearing trans-tibial prosthesis.
    Sin SW; Chow DH; Cheng JC
    Prosthet Orthot Int; 1999 Dec; 23(3):225-30. PubMed ID: 10890597
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In-vivo patellar tendon kinematics during weight-bearing deep knee flexion.
    Kobayashi K; Sakamoto M; Hosseini A; Rubash HE; Li G
    J Orthop Res; 2012 Oct; 30(10):1596-603. PubMed ID: 22492400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of an adjustable patellar tendon bearing prosthesis.
    Mizrahi J; Susak Z; Bahar A; Seliktar R; Najenson T
    Scand J Rehabil Med Suppl; 1985; 12():117-23. PubMed ID: 3868036
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Weight bearing and velocity in trans-tibial and trans-femoral amputees.
    Jones ME; Bashford GM; Mann JM
    Prosthet Orthot Int; 1997 Dec; 21(3):183-6. PubMed ID: 9453090
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects.
    Sanders JE; Jacobsen AK; Fergason JR
    Prosthet Orthot Int; 2006 Dec; 30(3):257-69. PubMed ID: 17162516
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Engineering a trans-tibial prosthetic socket for the lower limb amputee.
    Laing S; Lee PV; Goh JCh
    Ann Acad Med Singap; 2011 May; 40(5):252-9. PubMed ID: 21678017
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
    Lee VS; Solomonidis SE; Spence WD
    Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets.
    Holden JM; Fernie GR
    Prosthet Orthot Int; 1986 Dec; 10(3):142-8. PubMed ID: 3808920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.