These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 12812428)

  • 41. An Efficient Point-Matching Method-of-Moments for 2D and 3D Electrical Impedance Tomography Using Radial Basis Functions.
    Dimas C; Uzunoglu N; Sotiriadis PP
    IEEE Trans Biomed Eng; 2022 Feb; 69(2):783-794. PubMed ID: 34398750
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography.
    Frangi AF; Riu PJ; Rosell J; Viergever MA
    IEEE Trans Med Imaging; 2002 Jun; 21(6):566-78. PubMed ID: 12166852
    [TBL] [Abstract][Full Text] [Related]  

  • 43. An iterative Newton-Raphson method to solve the inverse admittivity problem.
    Edic PM; Isaacson D; Saulnier GJ; Jain H; Newell JC
    IEEE Trans Biomed Eng; 1998 Jul; 45(7):899-908. PubMed ID: 9644899
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Solution of the inverse problem of magnetic induction tomography (MIT) with multiple objects: analysis of detectability and statistical properties with respect to the reconstructed conducting region.
    Merwa R; Brunner P; Missner A; Hollaus K; Scharfetter H
    Physiol Meas; 2006 May; 27(5):S249-59. PubMed ID: 16636415
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Hybrid method for improving Tikhonov-based reconstruction quality in electrical impedance tomography.
    Wang M; Zheng S; Shi Y; Lou Y
    J Med Imaging (Bellingham); 2022 Sep; 9(5):054503. PubMed ID: 36267548
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography.
    Dehghani H; Barber DC; Basarab-Horwath I
    Physiol Meas; 1999 Feb; 20(1):87-102. PubMed ID: 10374829
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Higher order total variation regularization for EIT reconstruction.
    Gong B; Schullcke B; Krueger-Ziolek S; Zhang F; Mueller-Lisse U; Moeller K
    Med Biol Eng Comput; 2018 Aug; 56(8):1367-1378. PubMed ID: 29308547
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Electrical impedance tomography: regularized imaging and contrast detection.
    Adler A; Guardo R
    IEEE Trans Med Imaging; 1996; 15(2):170-9. PubMed ID: 18215899
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The application of the generalized vector sample pattern matching method for EIT image reconstruction.
    Dong G; Bayford RH; Gao S; Saito Y; Yerworth R; Holder D; Yan W
    Physiol Meas; 2003 May; 24(2):449-66. PubMed ID: 12812429
    [TBL] [Abstract][Full Text] [Related]  

  • 50. In vivo impedance imaging with total variation regularization.
    Borsic A; Graham BM; Adler A; Lionheart WR
    IEEE Trans Med Imaging; 2010 Jan; 29(1):44-54. PubMed ID: 20051330
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Electrical Impedance Tomography: Tissue Properties to Image Measures.
    Adler A; Boyle A
    IEEE Trans Biomed Eng; 2017 Nov; 64(11):2494-2504. PubMed ID: 28715324
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Supervised Descent Learning for Thoracic Electrical Impedance Tomography.
    Zhang K; Guo R; Li M; Yang F; Xu S; Abubakar A
    IEEE Trans Biomed Eng; 2021 Apr; 68(4):1360-1369. PubMed ID: 32997620
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Magnetic detection electrical impedance tomography with total variation regularization.
    Hao L; Li G; Xu L
    Biomed Mater Eng; 2014; 24(6):2857-64. PubMed ID: 25226991
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Individual thorax geometry reduces position and size differences in reconstructed images of electrical impedance tomography.
    Zhao Z; Frerichs I; Pulletz S; Müller-Lisse U; Möller K
    J Xray Sci Technol; 2014; 22(6):797-807. PubMed ID: 25408396
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Krylov subspace iterative techniques: on the detection of brain activity with electrical impedance tomography.
    Polydorides N; Lionheart WR; McCann H
    IEEE Trans Med Imaging; 2002 Jun; 21(6):596-603. PubMed ID: 12166855
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A novel combined regularization algorithm of total variation and Tikhonov regularization for open electrical impedance tomography.
    Liu J; Ling L; Li G
    Physiol Meas; 2013 Jul; 34(7):823-38. PubMed ID: 23787806
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Reconstruction of conductivity changes and electrode movements based on EIT temporal sequences.
    Dai T; Gómez-Laberge C; Adler A
    Physiol Meas; 2008 Jun; 29(6):S77-88. PubMed ID: 18544802
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reconstruction algorithm for frequency-differential EIT using absolute values.
    Menden T; Orschulik J; Dambrun S; Matuszczyk J; Santos SA; Leonhardt S; Walter M
    Physiol Meas; 2019 Apr; 40(3):034008. PubMed ID: 30818291
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns.
    Birgül O; Eyüboğlu BM; Ider YZ
    Phys Med Biol; 2003 Mar; 48(5):653-71. PubMed ID: 12696801
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
    Dong X; Niu T; Zhu L
    Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.