These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 12825298)

  • 1. Upscaling and automation of electrophysiology: toward high throughput screening in ion channel drug discovery.
    Asmild M; Oswald N; Krzywkowski KM; Friis S; Jacobsen RB; Reuter D; Taboryski R; Kutchinsky J; Vestergaard RK; Schrøder RL; Sørensen CB; Bech M; Korsgaard MP; Willumsen NJ
    Recept Channels; 2003; 9(1):49-58. PubMed ID: 12825298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrophysiological Studies of GABA
    Schupp M; Park SH; Qian B; Yu W
    Curr Protoc Pharmacol; 2020 Jun; 89(1):e75. PubMed ID: 32271492
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated ion channel screening: patch clamping made easy.
    Farre C; Stoelzle S; Haarmann C; George M; Brüggemann A; Fertig N
    Expert Opin Ther Targets; 2007 Apr; 11(4):557-65. PubMed ID: 17373884
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated planar electrode electrophysiology in drug discovery: examples of the use of QPatch in basic characterization and high content screening on Na(v), K(Ca)2.3, and K(v)11.1 channels.
    Korsgaard MP; Strøbaek D; Christophersen P
    Comb Chem High Throughput Screen; 2009 Jan; 12(1):51-63. PubMed ID: 19149491
    [TBL] [Abstract][Full Text] [Related]  

  • 5. QPatch: the missing link between HTS and ion channel drug discovery.
    Mathes C; Friis S; Finley M; Liu Y
    Comb Chem High Throughput Screen; 2009 Jan; 12(1):78-95. PubMed ID: 19149494
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated patch clamping using the QPatch.
    Jones KA; Garbati N; Zhang H; Large CH
    Methods Mol Biol; 2009; 565():209-23. PubMed ID: 19551364
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrophysiological Studies of Voltage-Gated Sodium Channels Using QPatch HT, an Automated Patch-Clamp System.
    Liu Y
    Curr Protoc Pharmacol; 2014 Jun; 65():11.14.1-45. PubMed ID: 24934605
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automated planar patch-clamp.
    Milligan CJ; Möller C
    Methods Mol Biol; 2013; 998():171-87. PubMed ID: 23529429
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High throughput electrophysiology: new perspectives for ion channel drug discovery.
    Willumsen NJ; Bech M; Olesen SP; Jensen BS; Korsgaard MP; Christophersen P
    Recept Channels; 2003; 9(1):3-12. PubMed ID: 12825293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. QPatch: the past, present and future of automated patch clamp.
    Mathes C
    Expert Opin Ther Targets; 2006 Apr; 10(2):319-27. PubMed ID: 16548779
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-throughput electrophysiology: an emerging paradigm for ion-channel screening and physiology.
    Dunlop J; Bowlby M; Peri R; Vasilyev D; Arias R
    Nat Rev Drug Discov; 2008 Apr; 7(4):358-68. PubMed ID: 18356919
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ion channel drug discovery and research: the automated Nano-Patch-Clamp technology.
    Brueggemann A; George M; Klau M; Beckler M; Steindl J; Behrends JC; Fertig N
    Curr Drug Discov Technol; 2004 Jan; 1(1):91-6. PubMed ID: 16472222
    [TBL] [Abstract][Full Text] [Related]  

  • 13. State-of-the-art automated patch clamp: heat activation, action potentials, and high throughput in ion channel screening.
    Stoelzle-Feix S
    Methods Mol Biol; 2014; 1183():65-80. PubMed ID: 25023302
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated electrophysiology in drug discovery.
    Priest BT; Swensen AM; McManus OB
    Curr Pharm Des; 2007; 13(23):2325-37. PubMed ID: 17692004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated patch clamp in drug discovery: major breakthroughs and innovation in the last decade.
    Obergrussberger A; Friis S; Brüggemann A; Fertig N
    Expert Opin Drug Discov; 2021 Jan; 16(1):1-5. PubMed ID: 32646308
    [No Abstract]   [Full Text] [Related]  

  • 16. Studying mechanosensitive ion channels with an automated patch clamp.
    Barthmes M; Jose MD; Birkner JP; Brüggemann A; Wahl-Schott C; Koçer A
    Eur Biophys J; 2014 Mar; 43(2-3):97-104. PubMed ID: 24526306
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance.
    Kutchinsky J; Friis S; Asmild M; Taboryski R; Pedersen S; Vestergaard RK; Jacobsen RB; Krzywkowski K; Schrøder RL; Ljungstrøm T; Hélix N; Sørensen CB; Bech M; Willumsen NJ
    Assay Drug Dev Technol; 2003 Oct; 1(5):685-93. PubMed ID: 15090241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contribution of Automated Technologies to Ion Channel Drug Discovery.
    Picones A; Loza-Huerta A; Segura-Chama P; Lara-Figueroa CO
    Adv Protein Chem Struct Biol; 2016; 104():357-378. PubMed ID: 27038379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. CYTOCENTERING: a novel technique enabling automated cell-by-cell patch clamping with the CYTOPATCH chip.
    Stett A; Burkhardt C; Weber U; van Stiphout P; Knott T
    Recept Channels; 2003; 9(1):59-66. PubMed ID: 12825299
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated high-throughput patch-clamp techniques.
    Shieh CC
    Drug Discov Today; 2004 Jul; 9(13):551-2. PubMed ID: 15203088
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.