These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 128348)

  • 1. Quantitative measurement of local blood flow with heat clearance.
    Müller-Schauenburg W; Apfel H; Benzing H; Betz E
    Basic Res Cardiol; 1975; 70(5):547-67. PubMed ID: 128348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A thermal method for the determination of tissue blood flow.
    McCaffrey TV; McCook RD
    J Appl Physiol; 1975 Jul; 39(1):170-3. PubMed ID: 125256
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of the in vivo recording of local cerebral blood flow using a thermistor device.
    Coremans J; Vermariën H; Vereecke F; Bourgain RH
    Adv Exp Med Biol; 1985; 191():139-48. PubMed ID: 3938598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Standardization of a device for continuous observation of local flow in tissue.
    Vermariën H; Coremans J; Vereecke F; Bourgain RH
    Adv Exp Med Biol; 1986; 200():143-50. PubMed ID: 3799301
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proposed methods for the measurement of regional renal blood flow using heat transfer analysis.
    Adams T; Spielman WS; Holmes KR; Heisey SR; Chen MM
    Ann Biomed Eng; 1985; 13(3-4):237-58. PubMed ID: 3898927
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An isothermal flowmeter with improved frequency response for measuring tissue blood flow.
    Olshausen K; Gross R; Kirchheim H
    Pflugers Arch; 1976 Nov; 367(1):97-102. PubMed ID: 137388
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A thermistor device for the continuous recording of mass transport velocity in tissue based on the heat clearance principle.
    Vermariën H; Coremans J; Vereecke F; Bourgain R
    Adv Exp Med Biol; 1984; 180():741-56. PubMed ID: 6534147
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal diffusion probe and instrument system for tissue blood flow measurements: validation in phantoms and in vivo organs.
    Delhomme G; Newman WH; Roussel B; Jouvet M; Bowman HF; Dittmar A
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):656-62. PubMed ID: 7927386
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blood flow rate, temperature, oxygen tension and consumption in the skin of adults measured by a heated microcathode oxygen electrode.
    Jaszczak P
    Dan Med Bull; 1988 Aug; 35(4):322-34. PubMed ID: 3048920
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of effects of a radiofrequency energy field and thermistor location in an electrode catheter on the accuracy of temperature measurement.
    Blouin LT; Marcus FI; Lampe L
    Pacing Clin Electrophysiol; 1991 May; 14(5 Pt 1):807-13. PubMed ID: 1712958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thermal quantification of region myocardial perfusion and heat generation.
    Hernandez EJ; Hoffman JK; Fabian M; Siegel JH; Eberhart RC
    Am J Physiol; 1979 Feb; 236(2):H345-55. PubMed ID: 420318
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Calibration of continuously monitored local blood flow in the canine myocardium by means of the heat clearance method].
    Benzing H; Rabe M
    Pflugers Arch; 1972; 332():Suppl 332:R51. PubMed ID: 5066039
    [No Abstract]   [Full Text] [Related]  

  • 13. A self-heated thermistor technique to measure effective thermal properties from the tissue surface.
    Patel PA; Valvano JW; Pearce JA; Prahl SA; Denham CR
    J Biomech Eng; 1987 Nov; 109(4):330-5. PubMed ID: 3695434
    [TBL] [Abstract][Full Text] [Related]  

  • 14. LOCAL BLOOD FLOW IN HUMAN LEG MUSCLE MEASURED BY A TRANSIENT RESPONSE THERMOELECTRIC METHOD.
    PERL W; CUCINELL SA
    Biophys J; 1965 Mar; 5(2):211-30. PubMed ID: 14268955
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Regional cerebral and extracranial blood flow measurements in acutely and chronically implanted cats: hydrogen clearance technique.
    Lamar JC; Carati P; Van Delft AM
    J Pharmacol Methods; 1981 May; 5(3):255-65. PubMed ID: 7311564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Simultaneous measurement of the local myocardial circulation with a heat conduction meter and krypton-85 clearance].
    Betz E; Hensel H; Du Mesnil De Rochemon
    Pflugers Arch Gesamte Physiol Menschen Tiere; 1966; 288(4):389-400. PubMed ID: 5233570
    [No Abstract]   [Full Text] [Related]  

  • 17. Regional blood flow in the cerebral cortex, measured simultaneously by heat and inert gas clearance.
    Betz E; Ingvar DH; Lassen NA; Schmahl FW
    Acta Physiol Scand; 1966 May; 67(1):1-9. PubMed ID: 5963297
    [No Abstract]   [Full Text] [Related]  

  • 18. Measurement of cerebral blood flow by washout of microwave induced heating.
    Lawner PM; Oldendorf WH; Braun LD
    Stroke; 1983; 14(5):776-80. PubMed ID: 6658965
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of thermal conductivity, thermal diffusivity, and perfusion.
    Yuan DY; Valvano JW; Anderson GT
    Biomed Sci Instrum; 1993; 29():435-42. PubMed ID: 8329624
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimal design of a thermistor probe for surface measurement of cerebral blood flow.
    Wei DT; Saidel GM; Jones SC
    IEEE Trans Biomed Eng; 1990 Dec; 37(12):1159-72. PubMed ID: 2289790
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.