117 related articles for article (PubMed ID: 12843725)
1. Relationship of the axillary nerve to the proximal screws of a flexible humeral nail system: an anatomic study.
Albritton MJ; Barnes CJ; Basamania CJ; Karas SG
J Orthop Trauma; 2003 Jul; 17(6):411-4. PubMed ID: 12843725
[TBL] [Abstract][Full Text] [Related]
2. The Relationship of Multiplanar Distal and Uniplanar Proximal Interlocking Screws to Neurovascular Structures with the Depuy Synthes Humeral Nail-EX: An Anatomic Study.
Steinmetz G; Tobey J; Skinner S; Hickerson L
J Orthop Trauma; 2018 Aug; 32(8):e300-e303. PubMed ID: 30028795
[TBL] [Abstract][Full Text] [Related]
3. Risk of injury to the axillary nerve during antegrade proximal humeral blade nail fixation - an anatomical study.
Spiegelberg BG; Riley ND; Taylor GJ
Injury; 2014 Aug; 45(8):1185-9. PubMed ID: 24907010
[TBL] [Abstract][Full Text] [Related]
4. A new risk to the axillary nerve during percutaneous proximal humeral plate fixation using the Synthes PHILOS aiming system.
Dang KH; Ornell SS; Reyes G; Hussey M; Dutta AK
J Shoulder Elbow Surg; 2019 Sep; 28(9):1795-1800. PubMed ID: 31031168
[TBL] [Abstract][Full Text] [Related]
5. The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants.
Prince EJ; Breien KM; Fehringer EV; Mormino MA
J Orthop Trauma; 2004 Oct; 18(9):585-8. PubMed ID: 15448445
[TBL] [Abstract][Full Text] [Related]
6. Anatomical and biomechanical evaluation of an intramedullary nail for fractures of proximal humerus fractures based on tuberosity fixation.
Clavert P; Hatzidakis A; Boileau P
Clin Biomech (Bristol, Avon); 2016 Feb; 32():108-12. PubMed ID: 26743868
[TBL] [Abstract][Full Text] [Related]
7. The risk of injury to the axillary nerve, artery, and vein from proximal locking screws of humeral intramedullary nails.
Riemer BL; D'Ambrosia R
Orthopedics; 1992 Jun; 15(6):697-9. PubMed ID: 1608862
[TBL] [Abstract][Full Text] [Related]
8. Anatomic study of the axillary nerve in a Chinese cadaveric population: correlation of the course of the nerve with proximal humeral fixation with intramedullary nail or external skeletal fixation.
Liu KY; Chen TH; Shyu JF; Wang ST; Liu JY; Chou PH
Arch Orthop Trauma Surg; 2011 May; 131(5):669-74. PubMed ID: 20811798
[TBL] [Abstract][Full Text] [Related]
9. Anatomic considerations of locked humeral nailing.
Lin J; Hou SM; Inoue N; Chao EY; Hang YS
Clin Orthop Relat Res; 1999 Nov; (368):247-54. PubMed ID: 10613175
[TBL] [Abstract][Full Text] [Related]
10. Straight proximal humeral nailing: Risk of iatrogenic tendon injuries with respect to different entry points in anatomical specimens.
Schwarz AM; Hohenberger GM; Euler S; Weiglein AH; Riedl R; Kuchling S; Krassnig R; Plecko M
Injury; 2018 Oct; 49(10):1750-1757. PubMed ID: 30017183
[TBL] [Abstract][Full Text] [Related]
11. Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study.
Esenyel CZ; Dedeoğlu S; Imren Y; Kahraman S; Çakar M; Öztürk K
Acta Orthop Traumatol Turc; 2014; 48(5):553-7. PubMed ID: 25429582
[TBL] [Abstract][Full Text] [Related]
12. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study.
Nijs S; Sermon A; Broos P
Patient Saf Surg; 2008 Dec; 2(1):33. PubMed ID: 19087350
[TBL] [Abstract][Full Text] [Related]
13. Qualitative and Quantitative Anatomy of the Proximal Humerus Muscle Attachments and the Axillary Nerve: A Cadaveric Study.
Moatshe G; Marchetti DC; Chahla J; Ferrari MB; Sanchez G; Lebus GF; Brady AW; Frank RM; LaPrade RF; Provencher MT
Arthroscopy; 2018 Mar; 34(3):795-803. PubMed ID: 29225017
[TBL] [Abstract][Full Text] [Related]
14. Axillary nerve palsy after retrograde humeral nailing: clinical confirmation of an anatomical fear.
Lögters TT; Wild M; Windolf J; Linhart W
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1431-5. PubMed ID: 18322690
[TBL] [Abstract][Full Text] [Related]
15. Anatomic evaluation of radiographic landmarks for accurate straight antegrade intramedullary nail placement in the humerus.
Johnston PS; Hatzidakis AM; Tagouri YM; Curran-Everett D; Sears BW
JSES Int; 2020 Dec; 4(4):745-752. PubMed ID: 33345210
[TBL] [Abstract][Full Text] [Related]
16. [Anatomy notes on minimally invasive plate osteosynthesis of the proximal humerus. A cadaver study].
Křivohlávek M; Taller S; Lukáš R; Dráč P
Acta Chir Orthop Traumatol Cech; 2014; 81(1):63-9. PubMed ID: 24755059
[TBL] [Abstract][Full Text] [Related]
17. Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study.
Apivatthakakul T; Patiyasikan S; Luevitoonvechkit S
Injury; 2010 Feb; 41(2):169-72. PubMed ID: 19735916
[TBL] [Abstract][Full Text] [Related]
18. Percutaneous insertion of a proximal humeral locking plate: an anatomic study.
Smith J; Berry G; Laflamme Y; Blain-Pare E; Reindl R; Harvey E
Injury; 2007 Feb; 38(2):206-11. PubMed ID: 17067606
[TBL] [Abstract][Full Text] [Related]
19. The risk of neurovascular injury with distal locking screws of humeral intramedullary nails.
Rupp RE; Chrissos MG; Ebraheim NA
Orthopedics; 1996 Jul; 19(7):593-5. PubMed ID: 8823817
[TBL] [Abstract][Full Text] [Related]
20. [Intramedullary fixation of humerus shaft fractures. An analysis of complications of 2 implants with special reference to outcome after management with the unreamed humerus interlocking nail].
Vécsei N; Kolonja A; Mousavi M; Vécsei V
Wien Klin Wochenschr; 2001 Aug; 113(15-16):597-604. PubMed ID: 11571838
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]