These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

53 related articles for article (PubMed ID: 12844476)

  • 1. The dependency of expiratory airway collapse on pump system and flow rate in liquid ventilated rabbits.
    Meinhardt JP; Ashton BA; Annich GM; Quintel M; Hirschl RB
    Eur J Med Res; 2003 May; 8(5):212-20. PubMed ID: 12844476
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and application of a double-piston configured, total-liquid ventilatory support device.
    Meinhardt JP; Quintel M; Hirschl RB
    Crit Care Med; 2000 May; 28(5):1483-8. PubMed ID: 10834700
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulmonary gas distribution during ventilation with different inspiratory flow patterns in experimental lung injury -- a computed tomography study.
    Roth H; Luecke T; Deventer B; Joachim A; Herrmann P; Quintel M
    Acta Anaesthesiol Scand; 2004 Aug; 48(7):851-61. PubMed ID: 15242429
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of repeated induced airway collapse during total liquid ventilation.
    Bagnoli P; Tredici S; Seetharamaiah R; Brant DO; Hewell LA; Johnson K; Bull JL; Costantino ML; Hirschl RB
    ASAIO J; 2007; 53(5):549-55. PubMed ID: 17885326
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of ventilatory variables on gas exchange and hemodynamics during total liquid ventilation in a rat model.
    Matsuda K; Sawada S; Bartlett RH; Hirschl RB
    Crit Care Med; 2003 Jul; 31(7):2034-40. PubMed ID: 12847401
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Controlled expiration in mechanically-ventilated patients with chronic obstructive pulmonary disease (COPD).
    Aerts JG; van den Berg B; Bogaard JM
    Eur Respir J; 1997 Mar; 10(3):550-6. PubMed ID: 9072983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of partial liquid ventilation in improving acute lung injury induced by intratracheal acidified infant formula: determination of optimal dose and positive end-expiratory pressure level.
    Mikawa K; Nishina K; Takao Y; Obara H
    Crit Care Med; 2004 Jan; 32(1):209-16. PubMed ID: 14707581
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
    Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR
    Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect on work of breathing of different continuous positive airway pressure devices evaluated in a premature neonatal lung model.
    Nikischin W; Petridis M; Noeske J; Spengler D; von Bismarck P
    Pediatr Crit Care Med; 2011 Nov; 12(6):e376-82. PubMed ID: 21499172
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of ventilator performance on airway pressure release ventilation: a model lung study.
    Yoshida T; Uchiyama A; Mashimo T; Fujino Y
    Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gas exchange during high frequency flow-interruption in rabbits before and after bronchoalveolar lavage.
    Sullivan KJ; Durand M; Ye TH; Chang HK
    Pediatr Res; 1988 Aug; 24(2):203-8. PubMed ID: 3141893
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Volume guarantee ventilation, interrupted expiration, and expiratory braking.
    McCallion N; Lau R; Dargaville PA; Morley CJ
    Arch Dis Child; 2005 Aug; 90(8):865-70. PubMed ID: 15886260
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of static airway pressures during total liquid ventilation while applying different expiratory modes and time patterns.
    Meinhardt JP; Sawada S; Quintel M; Hirschl RB
    ASAIO J; 2004; 50(1):68-75. PubMed ID: 14763494
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
    Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
    Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of the development of choked flow during total liquid ventilation.
    Baba Y; Brant D; Brah SS; Grotberg J; Bartlett RH; Hirschl RB
    Crit Care Med; 2004 Jan; 32(1):201-8. PubMed ID: 14707580
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prototype of a liquid ventilator using a novel hollow-fiber oxygenator in a rabbit model.
    Tredici S; Komori E; Funakubo A; Brant DO; Bull JL; Bartlett RH; Hirschl RB
    Crit Care Med; 2004 Oct; 32(10):2104-9. PubMed ID: 15483421
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of respiratory rate and tidal volume on gas exchange in total liquid ventilation.
    Bull JL; Tredici S; Fujioka H; Komori E; Grotberg JB; Hirschl RB
    ASAIO J; 2009; 55(4):373-81. PubMed ID: 19506467
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
    Delgado E; Hete B; Hoffman LA; Tasota FJ; Pinsky MR
    Respir Care; 2001 Jun; 46(6):577-85. PubMed ID: 11353546
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Physiopathology of acute respiratory failure in COPD and asthma].
    Mergoni M; Rossi A
    Minerva Anestesiol; 2001 Apr; 67(4):198-205. PubMed ID: 11376510
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.