120 related articles for article (PubMed ID: 12847532)
1. Operational evaluation of pulse oximetry in NICU patients with arterial access.
Gerstmann D; Berg R; Haskell R; Brower C; Wood K; Yoder B; Greenway L; Lassen G; Ogden R; Stoddard R; Minton S
J Perinatol; 2003; 23(5):378-83. PubMed ID: 12847532
[TBL] [Abstract][Full Text] [Related]
2. Reliability of conventional and new pulse oximetry in neonatal patients.
Hay WW; Rodden DJ; Collins SM; Melara DL; Hale KA; Fashaw LM
J Perinatol; 2002; 22(5):360-6. PubMed ID: 12082469
[TBL] [Abstract][Full Text] [Related]
3. Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers.
Shah N; Ragaswamy HB; Govindugari K; Estanol L
J Clin Anesth; 2012 Aug; 24(5):385-91. PubMed ID: 22626683
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of a third (Dolphin Voyager) versus first generation pulse oximeter (Nellcor N-180) in predicting arterial oxygen saturation and pulse rate in the anesthetized dog.
Burns PM; Driessen B; Boston R; Gunther RA
Vet Anaesth Analg; 2006 Sep; 33(5):281-95. PubMed ID: 16916350
[TBL] [Abstract][Full Text] [Related]
5. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.
Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D
J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251
[TBL] [Abstract][Full Text] [Related]
6. Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants.
Rosychuk RJ; Hudson-Mason A; Eklund D; Lacaze-Masmonteil T
Neonatology; 2012; 101(1):14-9. PubMed ID: 21791935
[TBL] [Abstract][Full Text] [Related]
7. The precision and accuracy of Nellcor and Masimo oximeters at low oxygen saturations (70%) in newborn lambs.
Dawson JA; Bastrenta P; Cavigioli F; Thio M; Ong T; Siew ML; Hooper SB; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2014 Jul; 99(4):F278-81. PubMed ID: 24596406
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of pulse oximetry readings in an animal model of low perfusion caused by emerging pneumonia and sepsis.
Hummler HD; Engelmann A; Pohlandt F; Högel J; Franz AR
Intensive Care Med; 2004 Apr; 30(4):709-13. PubMed ID: 14722632
[TBL] [Abstract][Full Text] [Related]
10. Performance Evaluation of New-Generation Pulse Oximeters in the NICU: Observational Study.
Nizami S; Greenwood K; Barrowman N; Harrold J
Cardiovasc Eng Technol; 2015 Sep; 6(3):383-91. PubMed ID: 26577369
[TBL] [Abstract][Full Text] [Related]
11. The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.
Foglia EE; Whyte RK; Chaudhary A; Mott A; Chen J; Propert KJ; Schmidt B
J Pediatr; 2017 Mar; 182():375-377.e2. PubMed ID: 27939107
[TBL] [Abstract][Full Text] [Related]
12. [Clinical usefulness of new-generation pulse oximetry in the paediatric cardiac surgery setting].
Cannesson M; Hénaine R; Di Filippo S; Neidecker J; Bompard D; Védrinne C; Lehot JJ
Ann Fr Anesth Reanim; 2008 Oct; 27(10):808-12. PubMed ID: 18835683
[TBL] [Abstract][Full Text] [Related]
13. Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis.
Torres A; Skender KM; Wohrley JD; Aldag JC; Raff GW; Bysani GK; Geiss DM
J Intensive Care Med; 2004; 19(4):229-34. PubMed ID: 15296623
[TBL] [Abstract][Full Text] [Related]
14. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion.
Schallom L; Sona C; McSweeney M; Mazuski J
Heart Lung; 2007; 36(3):188-94. PubMed ID: 17509425
[TBL] [Abstract][Full Text] [Related]
15. Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia.
Ottestad W; Kåsin JI; Høiseth LØ
Aerosp Med Hum Perform; 2018 Dec; 89(12):1045-1049. PubMed ID: 30487024
[No Abstract] [Full Text] [Related]
16. Accuracy of pulse oximetry in the intensive care unit.
Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L
Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301
[TBL] [Abstract][Full Text] [Related]
17. Individualised pulse oximetry limits in neonatal intensive care.
Gupta R; Yoxall CW; Subhedar N; Shaw NJ
Arch Dis Child Fetal Neonatal Ed; 1999 Nov; 81(3):F194-6. PubMed ID: 10525022
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of accuracy of pulse oximetry in newborn calves.
Uystepruyst CH; Coghe J; Bureau F; Lekeux P
Vet J; 2000 Jan; 159(1):71-6. PubMed ID: 10640413
[TBL] [Abstract][Full Text] [Related]
19. Motion resistant pulse oximetry in neonates.
Sahni R; Gupta A; Ohira-Kist K; Rosen TS
Arch Dis Child Fetal Neonatal Ed; 2003 Nov; 88(6):F505-8. PubMed ID: 14602699
[TBL] [Abstract][Full Text] [Related]
20. Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.
Workie FA; Rais-Bahrami K; Short BL
Am J Perinatol; 2005 Oct; 22(7):357-60. PubMed ID: 16215921
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]