219 related articles for article (PubMed ID: 12850927)
21. Planning of hyperthermic treatment for malignant glioma using computer simulation.
Uzuka T; Tanaka R; Takahashi H; Kakinuma K; Matsuda J; Kato K
Int J Hyperthermia; 2001; 17(2):114-22. PubMed ID: 11252356
[TBL] [Abstract][Full Text] [Related]
22. Conformal hyperthermia of superficial tumor with left-handed metamaterial lens applicator.
Tao Y; Wang G
IEEE Trans Biomed Eng; 2012 Dec; 59(12):3525-30. PubMed ID: 23033426
[TBL] [Abstract][Full Text] [Related]
23. Impact of nonlinear heat transfer on temperature control in regional hyperthermia.
Lang J; Erdmann B; Seebass M
IEEE Trans Biomed Eng; 1999 Sep; 46(9):1129-38. PubMed ID: 10493076
[TBL] [Abstract][Full Text] [Related]
24. External microwave hyperthermia combined with radiation therapy for extensive superficial chest wall recurrences.
Seegenschmiedt MH; Brady LW; Rossmeissl G
Recent Results Cancer Res; 1988; 107():147-51. PubMed ID: 3375547
[TBL] [Abstract][Full Text] [Related]
25. A variable microwave array attenuator for use with single-element waveguide applicators.
Sherar MD; Clark H; Cooper B; Kumaradas J; Liu FF
Int J Hyperthermia; 1994; 10(5):723-31. PubMed ID: 7806927
[TBL] [Abstract][Full Text] [Related]
26. Design and characterisation of miniaturised cavity-backed patch antenna for microwave hyperthermia.
Chakaravarthi G; Arunachalam K
Int J Hyperthermia; 2015; 31(7):737-48. PubMed ID: 26365603
[TBL] [Abstract][Full Text] [Related]
27. Utility of treatment planning for thermochemotherapy treatment of nonmuscle invasive bladder carcinoma.
Yuan Y; Cheng KS; Craciunescu OI; Stauffer PR; Maccarini PF; Arunachalam K; Vujaskovic Z; Dewhirst MW; Das SK
Med Phys; 2012 Mar; 39(3):1170-81. PubMed ID: 22380348
[TBL] [Abstract][Full Text] [Related]
28. Direct use of CT scans for hyperthermia treatment planning.
James BJ; Sullivan DM
IEEE Trans Biomed Eng; 1992 Aug; 39(8):845-51. PubMed ID: 1505997
[TBL] [Abstract][Full Text] [Related]
29. Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots.
Kok HP; Korshuize-van Straten L; Bakker A; de Kroon-Oldenhof R; Geijsen ED; Stalpers LJA; Crezee J
Int J Radiat Oncol Biol Phys; 2017 Nov; 99(4):1039-1047. PubMed ID: 28870786
[TBL] [Abstract][Full Text] [Related]
30. Thermal characteristics of microwave ablation in the vicinity of an arterial bifurcation.
Liu YJ; Qiao AK; Nan Q; Yang XY
Int J Hyperthermia; 2006 Sep; 22(6):491-506. PubMed ID: 16971369
[TBL] [Abstract][Full Text] [Related]
31. Broadband microwave spiral applicator (105-125 MHz) for
Walter J; Hader M; Sengedorj A; Fietkau R; Frey B; Gaipl US
Int J Hyperthermia; 2023; 40(1):2265590. PubMed ID: 37813393
[TBL] [Abstract][Full Text] [Related]
32. Temperature superposition for fast computation of 3D temperature distributions during optimization and planning of interstitial ultrasound hyperthermia treatments.
Salgaonkar VA; Prakash P; Diederich CJ
Int J Hyperthermia; 2012; 28(3):235-49. PubMed ID: 22515345
[TBL] [Abstract][Full Text] [Related]
33. Theoretical temperature distributions produced by an annular phased array-type system in CT-based patient models.
Paulsen KD; Strohbehn JW; Lynch DR
Radiat Res; 1984 Dec; 100(3):536-52. PubMed ID: 6505143
[TBL] [Abstract][Full Text] [Related]
34. Microwave applicator for hyperthermia treatment on in vivo melanoma model.
Togni P; Vrba J; Vannucci L
Med Biol Eng Comput; 2010 Mar; 48(3):285-92. PubMed ID: 20033789
[TBL] [Abstract][Full Text] [Related]
35. Initial results for automated computational modeling of patient-specific electromagnetic hyperthermia.
Piket-May MJ; Taflove A; Lin WC; Katz DS; Sathiaseelan V; Mittal BB
IEEE Trans Biomed Eng; 1992 Mar; 39(3):226-37. PubMed ID: 1555852
[TBL] [Abstract][Full Text] [Related]
36. Clinical evaluation and verification of the hyperthermia treatment planning system hyperplan.
Gellermann J; Wust P; Stalling D; Seebass M; Nadobny J; Beck R; Hege H; Deuflhard P; Felix R
Int J Radiat Oncol Biol Phys; 2000 Jul; 47(4):1145-56. PubMed ID: 10863088
[TBL] [Abstract][Full Text] [Related]
37. Large stationary microstrip arrays for superficial microwave hyperthermia at 433 MHz: SAR analysis and clinical data.
Ryan TP; Backus VL; Coughlin CT
Int J Hyperthermia; 1995; 11(2):187-209. PubMed ID: 7790734
[TBL] [Abstract][Full Text] [Related]
38. Investigation of the thermal and tissue injury behaviour in microwave thermal therapy using a porcine kidney model.
He X; McGee S; Coad JE; Schmidlin F; Iaizzo PA; Swanlund DJ; Kluge S; Rudie E; Bischof JC
Int J Hyperthermia; 2004 Sep; 20(6):567-93. PubMed ID: 15370815
[TBL] [Abstract][Full Text] [Related]
39. Beam shaping for microwave waveguide hyperthermia applicators.
Sherar MD; Liu FF; Newcombe DJ; Cooper B; Levin W; Taylor WB; Hunt JW
Int J Radiat Oncol Biol Phys; 1993 Apr; 25(5):849-57. PubMed ID: 8478236
[TBL] [Abstract][Full Text] [Related]
40. Delineation of potential hot spots for hyperthermia treatment planning optimisation.
Wiersma J; van Wieringen N; Crezee H; van Dijk JD
Int J Hyperthermia; 2007 May; 23(3):287-301. PubMed ID: 17523021
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]