These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 12852549)

  • 1. Inductively coupled rf coils for examinations of small animals and objects in standard whole-body MR scanners.
    Graf H; Martirosian P; Schick F; Grieser M; Bellemann ME
    Med Phys; 2003 Jun; 30(6):1241-5. PubMed ID: 12852549
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A combined solenoid-surface RF coil for high-resolution whole-brain rat imaging on a 3.0 Tesla clinical MR scanner.
    Underhill HR; Yuan C; Hayes CE
    Magn Reson Med; 2010 Sep; 64(3):883-92. PubMed ID: 20535812
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils.
    Paulus DH; Braun H; Aklan B; Quick HH
    Med Phys; 2012 Jul; 39(7):4306-15. PubMed ID: 22830764
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications.
    Alfonsetti M; Clementi V; Iotti S; Placidi G; Lodi R; Barbiroli B; Sotgiu A; Alecci M
    MAGMA; 2005 May; 18(2):69-75. PubMed ID: 15625584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study.
    Tellmann L; Quick HH; Bockisch A; Herzog H; Beyer T
    Med Phys; 2011 May; 38(5):2795-805. PubMed ID: 21776816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-field magnetic resonance imaging using solenoid radiofrequency coils.
    Vegh V; Gläser P; Maillet D; Cowin GJ; Reutens DC
    Magn Reson Imaging; 2012 Oct; 30(8):1177-85. PubMed ID: 22819180
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT).
    Scharfetter H; Merwa R; Pilz K
    Physiol Meas; 2005 Apr; 26(2):S307-18. PubMed ID: 15798243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A volume microstrip RF coil for MRI microscopy.
    Jasiński K; Młynarczyk A; Latta P; Volotovskyy V; Węglarz WP; Tomanek B
    Magn Reson Imaging; 2012 Jan; 30(1):70-7. PubMed ID: 22055746
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.
    Zhang X; Ugurbil K; Sainati R; Chen W
    IEEE Trans Biomed Eng; 2005 Mar; 52(3):495-504. PubMed ID: 15759580
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.
    Anumula S; Song HK; Wright AC; Wehrli FW
    Acad Radiol; 2005 Dec; 12(12):1521-6. PubMed ID: 16321740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. RF surface receive array coils: the art of an LC circuit.
    Fujita H; Zheng T; Yang X; Finnerty MJ; Handa S
    J Magn Reson Imaging; 2013 Jul; 38(1):12-25. PubMed ID: 23649497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A dedicated two-channel phased-array receiver coil for high-resolution MRI of the rat knee cartilage at 7 T.
    Rengle A; Armenean M; Bolbos R; Goebel JC; Pinzano-Watrin A; Saint-Jalmes H; Gillet P; Beuf O
    IEEE Trans Biomed Eng; 2009 Dec; 56(12):2891-7. PubMed ID: 19932985
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modular design of receiver coil arrays.
    De Zanche N; Massner JA; Leussler C; Pruessmann KP
    NMR Biomed; 2008 Jul; 21(6):644-54. PubMed ID: 18157799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimum maximum temperature gradient coil design.
    While PT; Poole MS; Forbes LK; Crozier S
    Magn Reson Med; 2013 Aug; 70(2):584-94. PubMed ID: 23042696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Modelling and design of extremely low frequency uniform magnetic field exposure apparatus for in vivo bioelectromagnetic studies.
    Cvetkovic D; Cosic I
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1675-8. PubMed ID: 18002296
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR-based measurements and simulations of the magnetic field created by a realistic transcranial magnetic stimulation (TMS) coil and stimulator.
    Mandija S; Petrov PI; Neggers SF; Luijten PR; van den Berg CA
    NMR Biomed; 2016 Nov; 29(11):1590-1600. PubMed ID: 27669678
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vivo absolute quantification for mouse muscle metabolites using an inductively coupled synthetic signal injection method and newly developed (1) H/(31) P dual tuned probe.
    Lee D; Marro K; Mathis M; Shankland E; Hayes C
    J Magn Reson Imaging; 2014 Apr; 39(4):1039-46. PubMed ID: 24464912
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of a miniature high-temperature superconducting (HTS) surface coil for in vivo microimaging of the mouse in a standard 1.5T clinical whole-body scanner.
    Poirier-Quinot M; Ginefri JC; Girard O; Robert P; Darrasse L
    Magn Reson Med; 2008 Oct; 60(4):917-27. PubMed ID: 18816812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Forward-looking intravascular orthogonal-solenoid coil for imaging and guidance in occlusive arterial disease.
    Anderson KJ; Leung G; Dick AJ; Wright GA
    Magn Reson Med; 2008 Aug; 60(2):489-95. PubMed ID: 18666117
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Method for nonlinear characterization of radio frequency coils made of high temperature superconducting material in view of magnetic resonance imaging applications.
    Girard O; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2007 Dec; 78(12):124703. PubMed ID: 18163742
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.