These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 12853252)
1. Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopy. Souto RM; Laz MM; Reis RL Biomaterials; 2003 Oct; 24(23):4213-21. PubMed ID: 12853252 [TBL] [Abstract][Full Text] [Related]
2. Influence of hydroxyapatite on the corrosion resistance of the Ti-13Nb-13Zr alloy. Duarte LT; Biaggio SR; Rocha-Filho RC; Bocchi N J Mater Sci Mater Med; 2009 May; 20(5):1009-15. PubMed ID: 19083081 [TBL] [Abstract][Full Text] [Related]
4. The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating in Hank's solution. Lavos-Valereto IC; Costa I; Wolynec S J Biomed Mater Res; 2002; 63(5):664-70. PubMed ID: 12209914 [TBL] [Abstract][Full Text] [Related]
5. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution. Lavos-Valereto IC; Wolynec S; Ramires I; Guastaldi AC; Costa I J Mater Sci Mater Med; 2004 Jan; 15(1):55-9. PubMed ID: 15338591 [TBL] [Abstract][Full Text] [Related]
6. Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate. Souto RM; Lemus MM; Reis RL J Biomed Mater Res A; 2004 Jul; 70(1):59-65. PubMed ID: 15174109 [TBL] [Abstract][Full Text] [Related]
7. Microstructure and mechanical properties of plasma sprayed HA/YSZ/Ti-6Al-4V composite coatings. Khor KA; Gu YW; Pan D; Cheang P Biomaterials; 2004 Aug; 25(18):4009-17. PubMed ID: 15046891 [TBL] [Abstract][Full Text] [Related]
8. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy. Grosgogeat B; Boinet M; Dalard F; Lissac M Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244 [TBL] [Abstract][Full Text] [Related]
9. Activity of plasma sprayed yttria stabilized zirconia reinforced hydroxyapatite/Ti-6Al-4V composite coatings in simulated body fluid. Gu YW; Khor KA; Pan D; Cheang P Biomaterials; 2004 Jul; 25(16):3177-85. PubMed ID: 14980413 [TBL] [Abstract][Full Text] [Related]
10. Nucleation and growth of apatite on chemically treated titanium alloy: an electrochemical impedance spectroscopy study. Wang CX; Wang M; Zhou X Biomaterials; 2003 Aug; 24(18):3069-77. PubMed ID: 12895579 [TBL] [Abstract][Full Text] [Related]
11. Effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates. Sousa SR; Barbosa MA Biomaterials; 1996 Feb; 17(4):397-404. PubMed ID: 8938233 [TBL] [Abstract][Full Text] [Related]
12. Electrochemical investigation of chromium oxide-coated Ti-6Al-4V and Co-Cr-Mo alloy substrates. Swaminathan V; Zeng H; Lawrynowicz D; Zhang Z; Gilbert JL J Biomed Mater Res B Appl Biomater; 2011 Aug; 98(2):369-78. PubMed ID: 21648063 [TBL] [Abstract][Full Text] [Related]
13. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin. Huang HH; Lee TH Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783 [TBL] [Abstract][Full Text] [Related]
14. Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution. Singh R; Tiwari SK; Mishra SK; Dahotre NB J Mater Sci Mater Med; 2011 Aug; 22(8):1787-96. PubMed ID: 21660586 [TBL] [Abstract][Full Text] [Related]
15. In vitro studies of plasma-sprayed hydroxyapatite/Ti-6Al-4V composite coatings in simulated body fluid (SBF). Gu YW; Khor KA; Cheang P Biomaterials; 2003 Apr; 24(9):1603-11. PubMed ID: 12559820 [TBL] [Abstract][Full Text] [Related]
16. In situ surface electrochemical characterizations of Ti and Ti-6Al-4V alloy cultured with osteoblast-like cells. Huang HH Biochem Biophys Res Commun; 2004 Feb; 314(3):787-92. PubMed ID: 14741704 [TBL] [Abstract][Full Text] [Related]
17. Preparation and characterization of sol-gel hydroxyapatite and its electrochemical evaluation for biomedical applications. Vijayalakshmi U; Prabakaran K; Rajeswari S J Biomed Mater Res A; 2008 Dec; 87(3):739-49. PubMed ID: 18200538 [TBL] [Abstract][Full Text] [Related]
18. Preparation and corrosion resistance of magnesium phytic acid/hydroxyapatite composite coatings on biodegradable AZ31 magnesium alloy. Zhang M; Cai S; Zhang F; Xu G; Wang F; Yu N; Wu X J Mater Sci Mater Med; 2017 Jun; 28(6):82. PubMed ID: 28424946 [TBL] [Abstract][Full Text] [Related]
19. Functionally gradient bonelike hydroxyapatite coating on a titanium metal substrate created by a discharging method in HBSS without organic molecules. Shibata Y; Takashima H; Yamamoto H; Miyazaki T Int J Oral Maxillofac Implants; 2004; 19(2):177-83. PubMed ID: 15101587 [TBL] [Abstract][Full Text] [Related]
20. Electrochemical behavior of Ti-6Al-4V alloy in static biosimulating solutions. Lewis G; Daigle K J Appl Biomater; 1993; 4(1):47-54. PubMed ID: 10148345 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]