BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

263 related articles for article (PubMed ID: 12853539)

  • 1. Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs.
    Hinz J; Neumann P; Dudykevych T; Andersson LG; Wrigge H; Burchardi H; Hedenstierna G
    Chest; 2003 Jul; 124(1):314-22. PubMed ID: 12853539
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography.
    Hentze B; Muders T; Luepschen H; Maripuu E; Hedenstierna G; Putensen C; Walter M; Leonhardt S
    Physiol Meas; 2018 Jun; 39(6):065004. PubMed ID: 29794336
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of relative lung perfusion with electrical impedance and positron emission tomography: an experimental comparative study in pigs.
    Bluth T; Kiss T; Kircher M; Braune A; Bozsak C; Huhle R; Scharffenberg M; Herzog M; Roegner J; Herzog P; Vivona L; Millone M; Dössel O; Andreeff M; Koch T; Kotzerke J; Stender B; Gama de Abreu M
    Br J Anaesth; 2019 Aug; 123(2):246-254. PubMed ID: 31160064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury*.
    Muders T; Luepschen H; Zinserling J; Greschus S; Fimmers R; Guenther U; Buchwald M; Grigutsch D; Leonhardt S; Putensen C; Wrigge H
    Crit Care Med; 2012 Mar; 40(3):903-11. PubMed ID: 22202705
    [TBL] [Abstract][Full Text] [Related]  

  • 5. EIT monitors valid and robust regional ventilation distribution in pathologic ventilation states in porcine study using differential DualEnergy-CT (ΔDECT).
    Reinartz SD; Imhoff M; Tolba R; Fischer F; Fischer EG; Teschner E; Koch S; Gärber Y; Isfort P; Gremse F
    Sci Rep; 2019 Jul; 9(1):9796. PubMed ID: 31278297
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure.
    Frerichs I; Hahn G; Hellige G
    IEEE Trans Med Imaging; 1999 Sep; 18(9):764-73. PubMed ID: 10571381
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography.
    Frerichs I; Hahn G; Golisch W; Kurpitz M; Burchardi H; Hellige G
    Acta Anaesthesiol Scand; 1998 Jul; 42(6):721-6. PubMed ID: 9689281
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury.
    Wrigge H; Zinserling J; Muders T; Varelmann D; Günther U; von der Groeben C; Magnusson A; Hedenstierna G; Putensen C
    Crit Care Med; 2008 Mar; 36(3):903-9. PubMed ID: 18431279
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrical impedance tomography for lung ventilation monitoring of the dog.
    Gloning S; Pieper K; Zoellner M; Meyer-Lindenberg A
    Tierarztl Prax Ausg K Kleintiere Heimtiere; 2017 Feb; 45(1):15-21. PubMed ID: 28094413
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monitoring of regional lung ventilation using electrical impedance tomography after cardiac surgery in infants and children.
    Krause U; Becker K; Hahn G; Dittmar J; Ruschewski W; Paul T
    Pediatr Cardiol; 2014 Aug; 35(6):990-7. PubMed ID: 24569885
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.
    Frerichs I; Schmitz G; Pulletz S; Schädler D; Zick G; Scholz J; Weiler N
    Physiol Meas; 2007 Jul; 28(7):S261-7. PubMed ID: 17664640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation.
    Frerichs I; Hahn G; Schiffmann H; Berger C; Hellige G
    Ann N Y Acad Sci; 1999 Apr; 873():493-505. PubMed ID: 10372185
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Regional distribution of ventilation in horses in dorsal recumbency during spontaneous and mechanical ventilation assessed by electrical impedance tomography: a case series.
    Mosing M; Marly-Voquer C; MacFarlane P; Bardell D; Böhm SH; Bettschart-Wolfensberger R; Waldmann AD
    Vet Anaesth Analg; 2017 Jan; 44(1):127-132. PubMed ID: 27483208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lobe based image reconstruction in Electrical Impedance Tomography.
    Schullcke B; Gong B; Krueger-Ziolek S; Tawhai M; Adler A; Mueller-Lisse U; Moeller K
    Med Phys; 2017 Feb; 44(2):426-436. PubMed ID: 28121374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography.
    Elke G; Fuld MK; Halaweish AF; Grychtol B; Weiler N; Hoffman EA; Frerichs I
    Physiol Meas; 2013 Oct; 34(10):1303-18. PubMed ID: 24021927
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated EIT system for functional lung ventilation imaging.
    Jang GY; Ayoub G; Kim YE; Oh TI; Chung CR; Suh GY; Woo EJ
    Biomed Eng Online; 2019 Jul; 18(1):83. PubMed ID: 31345220
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation.
    Bodenstein M; Boehme S; Bierschock S; Vogt A; David M; Markstaller K
    BMC Pulm Med; 2014 Apr; 14():73. PubMed ID: 24779960
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of individualized electrical impedance tomography and image reconstruction settings upon the assessment of regional ventilation distribution: Comparison to 4-dimensional computed tomography in a porcine model.
    Thürk F; Boehme S; Mudrak D; Kampusch S; Wielandner A; Prosch H; Braun C; Toemboel FPR; Hofmanninger J; Kaniusas E
    PLoS One; 2017; 12(8):e0182215. PubMed ID: 28763474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study.
    Richard JC; Pouzot C; Gros A; Tourevieille C; Lebars D; Lavenne F; Frerichs I; Guérin C
    Crit Care; 2009; 13(3):R82. PubMed ID: 19480694
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects.
    Riedel T; Richards T; Schibler A
    Intensive Care Med; 2005 Nov; 31(11):1522-8. PubMed ID: 16195908
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.