These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
235 related articles for article (PubMed ID: 12873570)
1. Accessing proximal aspects of folds and flexures during colonoscopy: impact of a pediatric colonoscope with a short bending section. Rex DK Am J Gastroenterol; 2003 Jul; 98(7):1504-7. PubMed ID: 12873570 [TBL] [Abstract][Full Text] [Related]
2. Impact of bending section length on insertion and retroflexion properties of pediatric and adult colonoscopes. Kessler WR; Rex DK Am J Gastroenterol; 2005 Jun; 100(6):1290-5. PubMed ID: 15929759 [TBL] [Abstract][Full Text] [Related]
3. Tapered colonoscope performs better than the pediatric colonoscope in female patients: a direct comparison through tandem colonoscopy. Anderson JC; Walker G; Birk JW; Alpern Z; Von Althen I Gastrointest Endosc; 2007 Jun; 65(7):1042-7. PubMed ID: 17331512 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a novel colonoscope designed for easier passage through flexures: a randomized study. Hoff G; Bretthauer M; Huppertz-Hauss G; Sauar J; Paulsen J; Dahler S; Kjellevold Ø Endoscopy; 2005 Nov; 37(11):1123-6. PubMed ID: 16281143 [TBL] [Abstract][Full Text] [Related]
5. Wide angle colonoscopy with a prototype instrument: impact on miss rates and efficiency as determined by back-to-back colonoscopies. Rex DK; Chadalawada V; Helper DJ Am J Gastroenterol; 2003 Sep; 98(9):2000-5. PubMed ID: 14499778 [TBL] [Abstract][Full Text] [Related]
6. A novel retrograde-viewing auxiliary imaging device (Third Eye Retroscope) improves the detection of simulated polyps in anatomic models of the colon. Triadafilopoulos G; Watts HD; Higgins J; Van Dam J Gastrointest Endosc; 2007 Jan; 65(1):139-44. PubMed ID: 17185094 [TBL] [Abstract][Full Text] [Related]
7. Use of a variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope. Shumaker DA; Zaman A; Katon RM Endoscopy; 2002 Sep; 34(9):711-4. PubMed ID: 12195328 [TBL] [Abstract][Full Text] [Related]
8. Long pediatric colonoscope versus intermediate length adult colonoscope for colonoscopy. Hsieh YH; Zhou AL; Lin HJ J Gastroenterol Hepatol; 2008 Jul; 23(7 Pt 2):e7-e10. PubMed ID: 18702687 [TBL] [Abstract][Full Text] [Related]
9. Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group. DeMarco DC; Odstrcil E; Lara LF; Bass D; Herdman C; Kinney T; Gupta K; Wolf L; Dewar T; Deas TM; Mehta MK; Anwer MB; Pellish R; Hamilton JK; Polter D; Reddy KG; Hanan I Gastrointest Endosc; 2010 Mar; 71(3):542-50. PubMed ID: 20189513 [TBL] [Abstract][Full Text] [Related]
10. A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos). Waye JD; Heigh RI; Fleischer DE; Leighton JA; Gurudu S; Aldrich LB; Li J; Ramrakhiani S; Edmundowicz SA; Early DS; Jonnalagadda S; Bresalier RS; Kessler WR; Rex DK Gastrointest Endosc; 2010 Mar; 71(3):551-6. PubMed ID: 20018280 [TBL] [Abstract][Full Text] [Related]
11. Colonoscopy technique in consecutive patients referred for prior incomplete colonoscopy. Rex DK; Chen SC; Overhiser AJ Clin Gastroenterol Hepatol; 2007 Jul; 5(7):879-83. PubMed ID: 17544873 [TBL] [Abstract][Full Text] [Related]
12. Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients. Rex DK Endoscopy; 2001 Jan; 33(1):60-4. PubMed ID: 11204989 [TBL] [Abstract][Full Text] [Related]
13. Cecal insertion and withdrawal times with wide-angle versus standard colonoscopes: a randomized controlled trial. Fatima H; Rex DK; Rothstein R; Rahmani E; Nehme O; Dewitt J; Helper D; Toor A; Bensen S Clin Gastroenterol Hepatol; 2008 Jan; 6(1):109-14. PubMed ID: 18065277 [TBL] [Abstract][Full Text] [Related]
14. A pilot study to assess the safety and efficacy of the Third Eye retrograde auxiliary imaging system during colonoscopy. Triadafilopoulos G; Li J Endoscopy; 2008 Jun; 40(6):478-82. PubMed ID: 18543136 [TBL] [Abstract][Full Text] [Related]
15. Use of a push enteroscope improves ability to perform total colonoscopy in previously unsuccessful attempts at colonoscopy in adult patients. Lichtenstein GR; Park PD; Long WB; Ginsberg GG; Kochman ML Am J Gastroenterol; 1999 Jan; 94(1):187-90. PubMed ID: 9934753 [TBL] [Abstract][Full Text] [Related]
16. Impact of proximal colon retroflexion on adenoma miss rates. Harrison M; Singh N; Rex DK Am J Gastroenterol; 2004 Mar; 99(3):519-22. PubMed ID: 15056095 [TBL] [Abstract][Full Text] [Related]
17. Efficacy of total colonoscopy with a transparent cap in comparison with colonoscopy without the cap. Matsushita M; Hajiro K; Okazaki K; Takakuwa H; Tominaga M Endoscopy; 1998 Jun; 30(5):444-7. PubMed ID: 9693890 [TBL] [Abstract][Full Text] [Related]
18. Emerging technological advancements in colonoscopy: Third Eye® Retroscope® and Third Eye® Panoramic(TM) , Fuse® Full Spectrum Endoscopy® colonoscopy platform, Extra-Wide-Angle-View colonoscope, and NaviAid(TM) G-EYE(TM) balloon colonoscope. Gralnek IM Dig Endosc; 2015 Jan; 27(2):223-31. PubMed ID: 25251748 [TBL] [Abstract][Full Text] [Related]
19. Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. Horiuchi A; Nakayama Y; Kajiyama M; Fujii H; Tanaka N Am J Gastroenterol; 2004 Oct; 99(10):1936-40. PubMed ID: 15447752 [TBL] [Abstract][Full Text] [Related]
20. Colonoscopic polypectomy in retroflexion. Rex DK; Khashab M Gastrointest Endosc; 2006 Jan; 63(1):144-8. PubMed ID: 16377332 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]