242 related articles for article (PubMed ID: 12875735)
1. Using Tc-99m MIBI scintimammography to differentiate nodular lesions in breast and detect axillary lymph node metastases from breast cancer.
Chen J; Wu H; Zhou J; Hu J
Chin Med J (Engl); 2003 Apr; 116(4):620-4. PubMed ID: 12875735
[TBL] [Abstract][Full Text] [Related]
2. Metastatic axillary lymph node technetium-99m-MIBI imaging in primary breast cancer.
Taillefer R; Robidoux A; Turpin S; Lambert R; Cantin J; Léveillé J
J Nucl Med; 1998 Mar; 39(3):459-64. PubMed ID: 9529292
[TBL] [Abstract][Full Text] [Related]
3. Technetium-99m-MIBI scintimammography by planar and SPECT imaging in the diagnosis of breast carcinoma and axillary lymph node involvement.
Myslivecek M; Koranda P; Kamínek M; Husák V; Hartlová M; Dusková M; Cwiertka K
Nucl Med Rev Cent East Eur; 2004; 7(2):151-5. PubMed ID: 15968602
[TBL] [Abstract][Full Text] [Related]
4. Detection of axillary lymph node metastasis of breast carcinoma with technetium-99m sestamibi scintimammography.
Tolmos J; Khalkhali I; Vargas H; Stuntz M; Cutrone J; Mishkin F; Diggles L; Venegas R; Klein S
Am Surg; 1997 Oct; 63(10):850-3. PubMed ID: 9322655
[TBL] [Abstract][Full Text] [Related]
5. Functional breast imaging with Tc 99m Mibi for detection of primary breast lesion and axillary lymph node metastases.
Usmani S; Khan HA; Javed A; Al Mohannadi S; Al Huda FA; Al Shammary I
Gulf J Oncolog; 2008 Jul; (4):52-7. PubMed ID: 20084776
[TBL] [Abstract][Full Text] [Related]
6. Tc-99m tetrofosmin in breast carcinoma and axillary lymph node metastases: a comparative study with Tc-99m MIBI.
Akçay MN; Akin Y; Karabağ B; Ozcan O; Oren D
Clin Nucl Med; 1997 Dec; 22(12):832-4. PubMed ID: 9408644
[TBL] [Abstract][Full Text] [Related]
7. Incremental diagnostic value of quantitative analysis of double phase Tc-99m MIBI scintimammography for the detection of primary breast cancer additive to visual analysis.
Kim SJ; Kim IJ; Bae YT; Kim YK; Kim DS
Breast Cancer Res Treat; 2004 Jan; 83(2):129-38. PubMed ID: 14997043
[TBL] [Abstract][Full Text] [Related]
8. Diagnostic accuracy of Tc-99m-MIBI for breast carcinoma in correlation with mammography and sonography.
Habib S; Maseeh-uz-Zaman ; Hameed A; Niaz K; Hashmi H; Kamal S
J Coll Physicians Surg Pak; 2009 Oct; 19(10):622-6. PubMed ID: 19811712
[TBL] [Abstract][Full Text] [Related]
9. 99mTc-(V)DMSA scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI.
Papantoniou V; Christodoulidou J; Papadaki E; Valotassiou V; Stipsanelli A; Louvrou A; Lazaris D; Sotiropoulou M; Pampouras G; Keramopoulos A; Michalas S; Zerva C
Eur J Nucl Med; 2001 Jul; 28(7):923-8. PubMed ID: 11504092
[TBL] [Abstract][Full Text] [Related]
10. (99M)Technetium-sestamibi scintimammography in non-palpable breast lesions found on screening X-ray mammography.
Gommans GM; van der Zant FM; van Dongen A; Boer RO; Teule GJ; de Waard JW
Eur J Surg Oncol; 2007 Feb; 33(1):23-7. PubMed ID: 17126524
[TBL] [Abstract][Full Text] [Related]
11. Technetium-99m-sestamibi prone scintimammography to detect primary breast cancer and axillary lymph node involvement.
Taillefer R; Robidoux A; Lambert R; Turpin S; Laperrière J
J Nucl Med; 1995 Oct; 36(10):1758-65. PubMed ID: 7562039
[TBL] [Abstract][Full Text] [Related]
12. The comparison of dual phase Tc-99m MIBI and tc-99m MDP scintimammography in the evaluation of breast masses: preliminary report.
Arslan N; Ozturk E; Ilgan S; Narin Y; Dundar S; Tufan T; Pekcan M; Bayhan H
Ann Nucl Med; 2000 Feb; 14(1):39-46. PubMed ID: 10770579
[TBL] [Abstract][Full Text] [Related]
13. Comparison of quantitative and visual analysis of Tc-99m MIBI scintimammography for detection of primary breast cancer.
Kim SJ; Kim IJ; Bae YT; Kim YK; Kim DS
Eur J Radiol; 2005 Feb; 53(2):192-8. PubMed ID: 15664282
[TBL] [Abstract][Full Text] [Related]
14. Value of 99m-Tc MIBI and 99m-Tc(V) DMSA scintigraphy in evaluation of breast mass lesions.
Ambrus E; Rajtár M; Ormándi K; Séra T; Tószegi A; Láng J; Pávics L; Csernay L
Anticancer Res; 1997; 17(3B):1599-605. PubMed ID: 9179201
[TBL] [Abstract][Full Text] [Related]
15. 99mTc-3P4-RGD2 scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI.
Ma Q; Chen B; Gao S; Ji T; Wen Q; Song Y; Zhu L; Xu Z; Liu L
PLoS One; 2014; 9(9):e108349. PubMed ID: 25250628
[TBL] [Abstract][Full Text] [Related]
16. [Breast carcinoma and the axillary lymph node status: the use of 99mTc-sestamibi scintimammography for the diagnosis and preoperative staging. Preliminary results].
Cistaro A; Bonazzi G; Bellò M; Bessone M; Tetti M; Villata E; Coluccia C; Bisi G; Massaioli N
Minerva Chir; 1997 Oct; 52(10):1177-82. PubMed ID: 9471568
[TBL] [Abstract][Full Text] [Related]
17. Correlation between uptake of Tc-99m sestaMIBI and prognostic factors of breast cancer.
Cwikla JB; Buscombe JR; Kolasinska AD; Parbhoo SP; Thakrar DS; Hilson AJ
Anticancer Res; 1999; 19(3B):2299-304. PubMed ID: 10472348
[TBL] [Abstract][Full Text] [Related]
18. The efficacy of (99m)Tc-MIBI scintimammography in the evaluation of breast lesions and axillary involvement: a comparison with X-rays mammography, ultrasonography and magnetic resonance imaging.
Ozülker T; Ozülker F; Ozpaçaci T; Bender O; Değirmenci H
Hell J Nucl Med; 2010; 13(2):144-9. PubMed ID: 20808988
[TBL] [Abstract][Full Text] [Related]
19. Comparison of fluorine-18 fluorodeoxyglucose positron emission tomography and technetium-99m methoxyisobutylisonitrile scintimammography in the detection of breast tumours.
Palmedo H; Bender H; Grünwald F; Mallmann P; Zamora P; Krebs D; Biersack HJ
Eur J Nucl Med; 1997 Sep; 24(9):1138-45. PubMed ID: 9283107
[TBL] [Abstract][Full Text] [Related]
20. Tc-99m MIBI uptake in breast carcinoma and axillary lymph node metastases.
Kao CH; Wang SJ; Yeh SH
Clin Nucl Med; 1994 Oct; 19(10):898-900. PubMed ID: 7805327
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]