These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 1287845)

  • 1. [Surgical treatment of dislocated 3 and 4-segment fractures of the proximal humerus].
    Rader CP; Keller HW; Rehm KE
    Unfallchirurg; 1992 Dec; 95(12):613-7. PubMed ID: 1287845
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Results of treatment after conservative and surgical management of proximal humerus fractures].
    Towfigh H; Bühl W; Obertacke U
    Aktuelle Traumatol; 1993 Dec; 23(8):354-60. PubMed ID: 8147254
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [T-plate osteosynthesis in dislocated proximal humerus fractures].
    Lill H; Lange K; Prasse-Badde J; Schmidt A; Verheyden P; Echtermeyer V
    Unfallchirurgie; 1997 Oct; 23(5):183-90; discussion 191-2. PubMed ID: 9446273
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous osteosynthesis of humeral head fractures.
    Aschauer E; Resch H; Hübner C
    Oper Orthop Traumatol; 2007 Aug; 19(3):276-93. PubMed ID: 17728985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Proximal humeral multiple fragment fractures--failures after T-plate osteosynthesis].
    Speck M; Lang FJ; Regazzoni P
    Swiss Surg; 1996; (2):51-6. PubMed ID: 8681108
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [High bone consolidation rates after humeral head-preserving revision surgery in non-unions of the proximal humerus].
    Aytac SD; Schnetzke M; Hudel I; Studier-Fischer S; Grützner PA; Gühring T
    Z Orthop Unfall; 2014 Dec; 152(6):596-602. PubMed ID: 25531521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fixation of fractures of the proximal humerus with the PlantTan Humerus Fixator Plate: early experience with a new implant.
    Sadowski C; Riand N; Stern R; Hoffmeyer P
    J Shoulder Elbow Surg; 2003; 12(2):148-51. PubMed ID: 12700567
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Timing of surgery for open reduction and internal fixation of displaced proximal humeral fractures.
    Siebenbürger G; Van Delden D; Helfen T; Haasters F; Böcker W; Ockert B
    Injury; 2015 Oct; 46 Suppl 4():S58-62. PubMed ID: 26542867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of functional outcomes in angle-stable osteosynthesis of comminuted fractures of the proximal humerus with those in percutaneous Kirschner-wire fixation. A prospective study of mid-term results].
    Edelmann K; Obruba P; Kopp L; Cihlář J; Celko AM
    Acta Chir Orthop Traumatol Cech; 2011; 78(4):314-20. PubMed ID: 21888841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Current concepts in plate and screw fixation of osteoporotic proximal humerus fractures.
    Ring D
    Injury; 2007 Sep; 38 Suppl 3():S59-68. PubMed ID: 17723794
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Late results following the surgical treatment of proximal humerus fractures in adults].
    Siebler G; Kuner EH
    Unfallchirurgie; 1985 Jun; 11(3):119-27. PubMed ID: 4035811
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [4-fragment fracture of the proximal upper arm].
    Kasperczyk WJ; Engel M; Tscherne H
    Unfallchirurg; 1993 Aug; 96(8):422-6. PubMed ID: 8378789
    [TBL] [Abstract][Full Text] [Related]  

  • 13. How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data.
    Schliemann B; Wähnert D; Theisen C; Herbort M; Kösters C; Raschke MJ; Weimann A
    Injury; 2015 Jul; 46(7):1207-14. PubMed ID: 25978864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Migration of Kirschner wires after surgical stabilization of injuries in the area of the shoulder--4 case reports].
    SchindeleS ; Hackenbruch W; Sutter F; Schärer M; Leutenegger A
    Swiss Surg; 1999; 5(6):281-7. PubMed ID: 10608191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?
    Königshausen M; Kübler L; Godry H; Citak M; Schildhauer TA; Seybold D
    Injury; 2012 Feb; 43(2):223-31. PubMed ID: 22001506
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Surgical treatment of 3- and 4-part fractures of the humeral head using a polyaxial-locking plate: results and patient satisfaction].
    Königshausen M; Thierbach A; Kübler L; Gessmann J; Godry H; Gothner M; Schildhauer TA; Seybold D
    Z Orthop Unfall; 2015 Feb; 153(1):51-8. PubMed ID: 25723581
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Closed percutaneous K-wire stabilization for displaced fractures of the surgical neck of the humerus.
    Kocialkowski A; Wallace WA
    Injury; 1990 Jul; 21(4):209-12. PubMed ID: 2228189
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Dislocated proximal humerus fracture--results after stabilization with a double plate].
    Wanner GA; Romero J; Hersche O; Smekal A; Ertel W
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1211-2. PubMed ID: 9931838
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three- and four-part proximal humerus fractures: open reduction and internal fixation versus arthroplasty.
    Farmer KW; Wright TW
    J Hand Surg Am; 2010 Nov; 35(11):1881-4; quiz 1884. PubMed ID: 20888144
    [No Abstract]   [Full Text] [Related]  

  • 20. Mennen clamp-on plate fixation of periprosthetic fractures of the humerus after shoulder arthroplasty--a report on 3 patients.
    Lill H; Hepp P; Rose T; Korner J; Josten C
    Acta Orthop Scand; 2004 Dec; 75(6):772-4. PubMed ID: 15762271
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.