These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 12882212)

  • 1. The standardized-taper root canal preparation--part 5. GT file technique in small root canals.
    Buchanan LS
    Int Endod J; 2001 Apr; 34(3):244-9. PubMed ID: 12882212
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The standardized-taper root canal preparation--Part 3. GT file technique in large root canals with small apical diameters.
    Buchanan LS
    Int Endod J; 2001 Mar; 34(2):149-56. PubMed ID: 11307264
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The standardized-taper root canal preparation--Part 2. GT file selection and safe handpiece-driven file use.
    Buchanan LS
    Int Endod J; 2001 Jan; 34(1):63-71. PubMed ID: 11307382
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The standardized-taper root canal preparation--Part 4. GT file technique in large root canals with large apical diameters.
    Buchanan LS
    Int Endod J; 2001 Mar; 34(2):157-64. PubMed ID: 11307265
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The standardized-taper root canal preparation--part 6. GT file technique in abruptly curved canals.
    Buchanan LS
    Int Endod J; 2001 Apr; 34(3):250-9. PubMed ID: 12882213
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Root canal preparation: shaping and cleaning of the root canal].
    Peters LB; Wesselink PR
    Ned Tijdschr Tandheelkd; 2005 Nov; 112(11):436-40. PubMed ID: 16320567
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The standardized-taper root canal preparation--Part 1. Concepts for variably tapered shaping instruments.
    Buchanan LS
    Int Endod J; 2000 Nov; 33(6):516-29. PubMed ID: 11307255
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determining the apical preparation size in premolars: part III.
    Hecker H; Bartha T; Löst C; Weiger R
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Jul; 110(1):118-24. PubMed ID: 20610301
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rotary nickel-titanium GT and ProTaper files for root canal shaping by novice operators: a radiographic and micro-computed tomography evaluation.
    Gekelman D; Ramamurthy R; Mirfarsi S; Paqué F; Peters OA
    J Endod; 2009 Nov; 35(11):1584-8. PubMed ID: 19840653
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impacts of conservative endodontic cavity on root canal instrumentation efficacy and resistance to fracture assessed in incisors, premolars, and molars.
    Krishan R; Paqué F; Ossareh A; Kishen A; Dao T; Friedman S
    J Endod; 2014 Aug; 40(8):1160-6. PubMed ID: 25069925
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vivo evaluation of two types of files used to accurately determine the diameter of the apical constriction of a root canal: an in vivo study.
    Darda S; Manwar N; Chandak M; Shori DD
    J Contemp Dent Pract; 2009 Jul; 10(4):43-50. PubMed ID: 19575053
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of root canal preparation on apical geometry assessed by micro-computed tomography.
    Paqué F; Ganahl D; Peters OA
    J Endod; 2009 Jul; 35(7):1056-9. PubMed ID: 19567334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators.
    Gluskin AH; Brown DC; Buchanan LS
    Int Endod J; 2001 Sep; 34(6):476-84. PubMed ID: 11556516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography.
    Marending M; Schicht OO; Paqué F
    Int Endod J; 2012 Feb; 45(2):169-76. PubMed ID: 21992481
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the first file that fits at the apex, before and after early flaring.
    Contreras MA; Zinman EH; Kaplan SK
    J Endod; 2001 Feb; 27(2):113-6. PubMed ID: 11491634
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study.
    Drukteinis S; Peciuliene V; Dummer PMH; Hupp J
    Int Endod J; 2019 Jan; 52(1):86-93. PubMed ID: 29858500
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Crown-down preflaring in the determination of the first apical file.
    Silveira LF; Silveira CF; Castro LA; César Neto JB; Martos J
    Braz Oral Res; 2010; 24(2):153-7. PubMed ID: 20658032
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper.
    Bürklein S; Hinschitza K; Dammaschke T; Schäfer E
    Int Endod J; 2012 May; 45(5):449-61. PubMed ID: 22188401
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Early flaring and crown-down shaping influences the first file bind to the canal apical third.
    Silveira LF; Martos J; Pintado LS; Teixeira RA; César Neto JB
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Aug; 106(2):e99-101. PubMed ID: 18554942
    [No Abstract]   [Full Text] [Related]  

  • 20. Influence of cervical preflaring on apical file size determination.
    Pecora JD; Capelli A; Guerisoli DM; Spanó JC; Estrela C
    Int Endod J; 2005 Jul; 38(7):430-5. PubMed ID: 15946262
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.