1. Closed-loop control if the inspired fraction of oxygen in mechanical ventilation.
Tehrani F; Rogers M; Lo T; Malinowski T; Afuwape S; Lum M; Grundl B; Terry M
J Clin Monit Comput; 2002 Aug; 17(6):367-76. PubMed ID: 12885181
[TBL] [Abstract][Full Text] [Related]
2. A dual closed-loop control system for mechanical ventilation.
Tehrani F; Rogers M; Lo T; Malinowski T; Afuwape S; Lum M; Grundl B; Terry M
J Clin Monit Comput; 2004 Apr; 18(2):111-29. PubMed ID: 15362273
[TBL] [Abstract][Full Text] [Related]
3. FIx controller: an instrument to automatically adjust inspired oxygen fraction using feedback control from a pulse oximeter.
Raemer DB; Ji XB; Topulos GP
J Clin Monit; 1997 Mar; 13(2):91-101. PubMed ID: 9112204
[TBL] [Abstract][Full Text] [Related]
4. Feasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation.
Saihi K; Richard JC; Gonin X; Krüger T; Dojat M; Brochard L
Crit Care; 2014 Feb; 18(2):R35. PubMed ID: 24552490
[TBL] [Abstract][Full Text] [Related]
5. Applying Computer Models to Realize Closed-Loop Neonatal Oxygen Therapy.
Morozoff E; Smyth JA; Saif M
Anesth Analg; 2017 Jan; 124(1):95-103. PubMed ID: 27992386
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of three automatic oxygen therapy control algorithms on ventilated low birth weight neonates.
Morozoff EP; Smyth JA
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3079-82. PubMed ID: 19963561
[TBL] [Abstract][Full Text] [Related]
7. Closed loop control of inspired oxygen concentration in trauma patients.
Johannigman JA; Branson RD; Edwards MG
J Am Coll Surg; 2009 May; 208(5):763-8; discussion 768-9. PubMed ID: 19476833
[TBL] [Abstract][Full Text] [Related]
8. A closed-loop controller for mechanical ventilation of patients with ARDS.
Anderson JR; East TD
Biomed Sci Instrum; 2002; 38():289-94. PubMed ID: 12085618
[TBL] [Abstract][Full Text] [Related]
9. An optimal interval type-2 fuzzy logic control based closed-loop drug administration to regulate the mean arterial blood pressure.
Sharma R; Deepak KK; Gaur P; Joshi D
Comput Methods Programs Biomed; 2020 Mar; 185():105167. PubMed ID: 31715333
[TBL] [Abstract][Full Text] [Related]
10. Development and preclinical testing of an adaptive algorithm for automated control of inspired oxygen in the preterm infant.
Dargaville PA; Sadeghi Fathabadi O; Plottier GK; Lim K; Wheeler KI; Jayakar R; Gale TJ
Arch Dis Child Fetal Neonatal Ed; 2017 Jan; 102(1):F31-F36. PubMed ID: 27634820
[TBL] [Abstract][Full Text] [Related]
11. Is faster better? A randomised crossover study comparing algorithms for closed-loop automatic oxygen control.
Schwarz CE; Kidszun A; Bieder NS; Franz AR; König J; Mildenberger E; Poets CF; Seyfang A; Urschitz MS
Arch Dis Child Fetal Neonatal Ed; 2020 Jul; 105(4):369-374. PubMed ID: 31527093
[TBL] [Abstract][Full Text] [Related]
12. Oximetry feedback flow control simulation for oxygen therapy.
Iobbi MG; Simonds AK; Dickinson RJ
J Clin Monit Comput; 2007 Apr; 21(2):115-23. PubMed ID: 17205376
[TBL] [Abstract][Full Text] [Related]
13. A microcomputer oxygen control system for ventilatory therapy.
Tehrani FT
Ann Biomed Eng; 1992; 20(5):547-58. PubMed ID: 1416290
[TBL] [Abstract][Full Text] [Related]
14. A closed-loop system for control of the fraction of inspired oxygen and the positive end-expiratory pressure in mechanical ventilation.
Tehrani FT
Comput Biol Med; 2012 Nov; 42(11):1150-6. PubMed ID: 23058098
[TBL] [Abstract][Full Text] [Related]
15. Oxygen therapy in critical illness: precise control of arterial oxygenation and permissive hypoxemia.
Martin DS; Grocott MP
Crit Care Med; 2013 Feb; 41(2):423-32. PubMed ID: 23263574
[TBL] [Abstract][Full Text] [Related]
16. Targeting Arterial Oxygen Saturation by Closed-Loop Control of Inspired Oxygen in Preterm Infants.
Claure N; Bancalari E
Clin Perinatol; 2019 Sep; 46(3):567-577. PubMed ID: 31345547
[TBL] [Abstract][Full Text] [Related]
17. Correlation of oxygen saturation as measured by pulse oximetry/fraction of inspired oxygen ratio with Pao2/fraction of inspired oxygen ratio in a heterogeneous sample of critically ill children.
Lobete C; Medina A; Rey C; Mayordomo-Colunga J; Concha A; Menéndez S
J Crit Care; 2013 Aug; 28(4):538.e1-7. PubMed ID: 23395312
[TBL] [Abstract][Full Text] [Related]
18. Automated adjustments of inspired fraction of oxygen to avoid hypoxemia and hyperoxemia in neonates - a systematic review on clinical studies.
Hummler H; Fuchs H; Schmid M
Klin Padiatr; 2014 Jul; 226(4):204-10. PubMed ID: 25010125
[TBL] [Abstract][Full Text] [Related]
19. Hypoxemia Episodes during Day and Night and Their Impact on Oxygen Saturation Targeting in Mechanically Ventilated Preterm Infants.
Jain D; D'Ugard C; Bello J; Bancalari E; Claure N
Neonatology; 2018; 113(1):69-74. PubMed ID: 29084407
[TBL] [Abstract][Full Text] [Related]
20. Automated closed loop control of inspired oxygen concentration.
Claure N; Bancalari E
Respir Care; 2013 Jan; 58(1):151-61. PubMed ID: 23271825
[TBL] [Abstract][Full Text] [Related]