BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 12895575)

  • 1. Evaluation of corrosion on plasma sprayed and anodized titanium implants, both with and without bone cement.
    Reclaru L; Lerf R; Eschler PY; Blatter A; Meyer JM
    Biomaterials; 2003 Aug; 24(18):3027-38. PubMed ID: 12895575
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrochemical corrosion and metal ion release from Co-Cr-Mo prosthesis with titanium plasma spray coating.
    Reclaru L; Eschler PY; Lerf R; Blatter A
    Biomaterials; 2005 Aug; 26(23):4747-56. PubMed ID: 15763254
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Electrochemical properties of biocompatible material hardness modifications on titanium and steel under mechanical loads].
    Braun W; Walter U; Holbein R; Thull R
    Biomed Tech (Berl); 2005 Apr; 50(4):100-6. PubMed ID: 15884706
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate.
    Souto RM; Lemus MM; Reis RL
    J Biomed Mater Res A; 2004 Jul; 70(1):59-65. PubMed ID: 15174109
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stainless steel surface biofunctionalization with PMMA-bioglass coatings: compositional, electrochemical corrosion studies and microbiological assay.
    Floroian L; Samoila C; Badea M; Munteanu D; Ristoscu C; Sima F; Negut I; Chifiriuc MC; Mihailescu IN
    J Mater Sci Mater Med; 2015 Jun; 26(6):195. PubMed ID: 26085116
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro study of electrodeposited fluoridated hydroxyapatite coating on G-II titanium with a nanostructured TiO
    Lin JS; Tsai TB; Say WC; Chiu C; Chen SH
    Biomed Mater; 2017 Apr; 12(2):025018. PubMed ID: 28374679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved mechanical properties of acrylic bone cement with short titanium fiber reinforcement.
    Kotha SP; Li C; McGinn P; Schmid SR; Mason JJ
    J Mater Sci Mater Med; 2006 Aug; 17(8):743-8. PubMed ID: 16897167
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion.
    Mueller Y; Tognini R; Mayer J; Virtanen S
    J Biomed Mater Res A; 2007 Sep; 82(4):936-46. PubMed ID: 17335021
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modification of Ti6Al4V implant surfaces by biocompatible TiO
    Catauro M; Bollino F; Giovanardi R; Veronesi P
    Mater Sci Eng C Mater Biol Appl; 2017 May; 74():501-507. PubMed ID: 28254324
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparation of bone-implants by coating hydroxyapatite nanoparticles on self-formed titanium dioxide thin-layers on titanium metal surfaces.
    Wijesinghe WP; Mantilaka MM; Chathuranga Senarathna KG; Herath HM; Premachandra TN; Ranasinghe CS; Rajapakse RP; Rajapakse RM; Edirisinghe M; Mahalingam S; Bandara IM; Singh S
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():172-84. PubMed ID: 27040209
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion resistance and biocompatibility of a new porous surface for titanium implants.
    Simon M; Lagneau C; Moreno J; Lissac M; Dalard F; Grosgogeat B
    Eur J Oral Sci; 2005 Dec; 113(6):537-45. PubMed ID: 16324146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution.
    Metikos-Huković M; Kwokal A; Piljac J
    Biomaterials; 2003 Sep; 24(21):3765-75. PubMed ID: 12818549
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The role of lipopolysaccharide on the electrochemical behavior of titanium.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    J Dent Res; 2011 May; 90(5):613-8. PubMed ID: 21335537
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface modification of stainless steel orthopedic implants by sol-gel ZrTiO4 and ZrTiO4-PMMA coatings.
    Salahinejad E; Hadianfard MJ; Macdonald DD; Sharifi Asl S; Mozafari M; Walker KJ; Rad AT; Madihally SV; Vashaee D; Tayebi L
    J Biomed Nanotechnol; 2013 Aug; 9(8):1327-35. PubMed ID: 23926798
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications.
    Frauchiger VM; Schlottig F; Gasser B; Textor M
    Biomaterials; 2004 Feb; 25(4):593-606. PubMed ID: 14607497
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro studying corrosion behavior of porous titanium coating in dynamic electrolyte.
    Chen X; Fu Q; Jin Y; Li M; Yang R; Cui X; Gong M
    Mater Sci Eng C Mater Biol Appl; 2017 Jan; 70(Pt 2):1071-1075. PubMed ID: 27772706
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technological capabilities of surface layers formation on implant made of Ti-6Al-4V ELI alloy.
    Kiel-Jamrozik M; Szewczenko J; Basiaga M; Nowińska K
    Acta Bioeng Biomech; 2015; 17(1):31-7. PubMed ID: 25952459
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of pH on the electrochemical behaviour of titanium alloys for implant applications.
    Souza ME; Lima L; Lima CR; Zavaglia CA; Freire CM
    J Mater Sci Mater Med; 2009 Feb; 20(2):549-52. PubMed ID: 18987951
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surface characteristics and electrochemical corrosion behavior of a pre-anodized microarc oxidation coating on titanium alloy.
    Cui WF; Jin L; Zhou L
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):3775-9. PubMed ID: 23910276
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterizations of three surface-modified titanium oxide films.
    Wang G; Cheng XR
    Chin J Dent Res; 2000 Aug; 3(2):49-52. PubMed ID: 11314519
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.