These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 12905720)

  • 1. [Detection of esophageal intubation-assessment of several methods in clinical anesthesia].
    Li CH; Zhao W; Zhang JH; Jia NG
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2003 Apr; 25(2):197-200. PubMed ID: 12905720
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A clinical study of impedance graph in verifying tracheal intubation].
    Yao YX; Jiang Z; Lu XH; He JH; Ma XX; Zhu JH
    Zhonghua Yi Xue Za Zhi; 2007 Apr; 87(13):898-901. PubMed ID: 17650400
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of three different methods to confirm tracheal tube placement in emergency intubation.
    Grmec S
    Intensive Care Med; 2002 Jun; 28(6):701-4. PubMed ID: 12107674
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of the Rapiscope vs chest auscultation for detection of accidental bronchial intubation in non-obese patients undergoing laparoscopic cholecystectomy.
    Ezri T; Khazin V; Szmuk P; Medalion B; Shechter P; Priel I; Loberboim M; Weinbroum AA
    J Clin Anesth; 2006 Mar; 18(2):118-23. PubMed ID: 16563329
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Verification of endotracheal intubation in obese patients - temporal comparison of ultrasound vs. auscultation and capnography.
    Pfeiffer P; Bache S; Isbye DL; Rudolph SS; Rovsing L; Børglum J
    Acta Anaesthesiol Scand; 2012 May; 56(5):571-6. PubMed ID: 22260400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Anesthesia accidents: accidental esophageal intubation].
    Frova G; Tuzzo D
    Minerva Anestesiol; 1999 Jun; 65(6):362-6. PubMed ID: 10394802
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative study of methods of detection of esophageal intubation.
    Sum-Ping ST; Mehta MP; Anderton JM
    Anesth Analg; 1989 Nov; 69(5):627-32. PubMed ID: 2508509
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of capnography in the delivery room for assessment of endotracheal tube placement.
    Repetto JE; Donohue PA-C PK; Baker SF; Kelly L; Nogee LM
    J Perinatol; 2001; 21(5):284-7. PubMed ID: 11536020
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of airway CO2 partial pressure to avoid esophageal intubation.
    Ko FY; Hsieh KS; Yu CK
    Zhonghua Min Guo Xiao Er Ke Yi Xue Hui Za Zhi; 1993; 34(2):91-7. PubMed ID: 8372677
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Delayed detection of esophageal intubation: Thai Anesthesia Incidents Study (THAI Study) database of 163,403 cases.
    Chinachoti T; Suraseranivongse S; Pengpol W; Valairucha S
    J Med Assoc Thai; 2005 Nov; 88 Suppl 7():S69-75. PubMed ID: 16858985
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement.
    Pfeiffer P; Rudolph SS; Børglum J; Isbye DL
    Acta Anaesthesiol Scand; 2011 Nov; 55(10):1190-5. PubMed ID: 22092123
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The assessment of four different methods to verify tracheal tube placement in the critical care setting.
    Knapp S; Kofler J; Stoiser B; Thalhammer F; Burgmann H; Posch M; Hofbauer R; Stanzel M; Frass M
    Anesth Analg; 1999 Apr; 88(4):766-70. PubMed ID: 10195521
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Another source of airway-leakage: inadvertent endobronchial misplacement of nasogastric tube in a patient intubated with double-lumen endotracheal tube under anesthesia.
    Hung MH; Hsieh PF; Lee SC; Chan KC
    Acta Anaesthesiol Taiwan; 2007 Dec; 45(4):241-4. PubMed ID: 18251247
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel method to detect accidental oesophageal intubation based on ventilation pressure waveforms.
    Kalmar AF; Absalom A; Monsieurs KG
    Resuscitation; 2012 Feb; 83(2):177-82. PubMed ID: 22044726
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A role of end-tidal CO(2) monitoring for assessment of tracheal intubations in very low birth weight infants during neonatal resuscitation at birth.
    Hosono S; Inami I; Fujita H; Minato M; Takahashi S; Mugishima H
    J Perinat Med; 2009; 37(1):79-84. PubMed ID: 18976048
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inability to detect unintentional endobronchial intubation by conventional signs and its detection by the radiologist during fluoroscopy for cerebral aneurysm coiling.
    Kapur S; Aragola S; Yates D
    J Clin Anesth; 2007 Mar; 19(2):138-40. PubMed ID: 17379128
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Case report: vibration response imaging findings following inadvertent esophageal intubation.
    Cinel I; Jean S; Tay C; Gratz I; Deal E; Parrillo JE; Dellinger RP
    Can J Anaesth; 2008 Mar; 55(3):172-6. PubMed ID: 18310628
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Out-of-hospital esophageal and endobronchial intubations performed by emergency physicians.
    Leissner KB; Srinivasa V
    Anesth Analg; 2007 Oct; 105(4):1167. PubMed ID: 17898409
    [No Abstract]   [Full Text] [Related]  

  • 19. Video stethoscope--a simple method for assuring continuous bilateral lung ventilation during anesthesia.
    Huang KC; Kraman SS; Wright BD
    Anesth Analg; 1983 Jun; 62(6):586-9. PubMed ID: 6846882
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.
    Goldberg JS; Rawle PR; Zehnder JL; Sladen RN
    Anesth Analg; 1990 Feb; 70(2):191-4. PubMed ID: 2105671
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.