137 related articles for article (PubMed ID: 12914618)
1. Clinical performance of automatic closed-loop stimulation systems.
Griesbach L; Gestrich B; Wojciechowski D; Weyers G; Tönges J; Schier M; Danilovic D;
Pacing Clin Electrophysiol; 2003 Jul; 26(7 Pt 1):1432-7. PubMed ID: 12914618
[TBL] [Abstract][Full Text] [Related]
2. Atrial rate adaptive pacing: what happens to AV conduction?
Linde C; Nordlander R; Rosenqvist M
Pacing Clin Electrophysiol; 1994 Oct; 17(10):1581-9. PubMed ID: 7800559
[TBL] [Abstract][Full Text] [Related]
3. A comparative study of activity and dual sensor: activity and minute ventilation pacing responses to ascending and descending stairs.
Alt E; Combs W; Willhaus R; Condie C; Bambl E; Fotuhi P; Pache J; Schömig A
Pacing Clin Electrophysiol; 1998 Oct; 21(10):1862-8. PubMed ID: 9793080
[TBL] [Abstract][Full Text] [Related]
4. Comparison of continuously recorded sensor and sinus rates during daily life activities and standardized exercise testing: efficacy of automatically optimized rate adaptive dual sensor pacing to simulate sinus rhythm.
Lau CP; Leung SK; Guerola M; Crijns HJ
Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1672-7. PubMed ID: 8945022
[TBL] [Abstract][Full Text] [Related]
5. Comparison of normal sinus rhythm and pacing rate in children with minute ventilation single chamber rate adaptive permanent pacemakers.
Celiker A; Ceviz N; Alehan D; Lenk MK; Ozme S
Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2100-4. PubMed ID: 9826863
[TBL] [Abstract][Full Text] [Related]
6. Benefits and limitations of rate adaptive pacing under laboratory and daily life conditions in patients with minute ventilation single chamber pacemakers.
Osswald S; Leiggener C; Buser PT; Pfisterer ME; Burckhardt D; Burkart F
Pacing Clin Electrophysiol; 1996 Jun; 19(6):890-8. PubMed ID: 8774818
[TBL] [Abstract][Full Text] [Related]
7. Rate response of a closed-loop stimulation pacing system to changing preload and afterload conditions.
Cron TA; Pouskoulas CD; Keller DI; Zaugg CE; Buser PT; Pfisterer ME; Osswald S; Hilti P; Schächinger H
Pacing Clin Electrophysiol; 2003 Jul; 26(7 Pt 1):1504-10. PubMed ID: 12914629
[TBL] [Abstract][Full Text] [Related]
8. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: quantification of chronotropic behavior during daily activities and maximal exercise.
Lau CP; Tai YT; Leung WH; Leung SK; Li JP; Wong CK; Lee IS; Yerich C; Erickson M
Pacing Clin Electrophysiol; 1994 Dec; 17(12 Pt 1):2236-46. PubMed ID: 7885930
[TBL] [Abstract][Full Text] [Related]
9. Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers.
Wiegand UK; Bode F; Peters W; Haase H; Bonnemeier H; Katus HA; Potratz J
Pacing Clin Electrophysiol; 2000 Apr; 23(4 Pt 1):427-33. PubMed ID: 10793429
[TBL] [Abstract][Full Text] [Related]
10. Clinical observations with Closed Loop Stimulation pacemakers in a large patient cohort: the CYLOS routine documentation registry (RECORD).
Lindovská M; Kameník L; Pollock B; Hoenen S; Bökelmann T; Spitzer W; Salbach P; Behroz A; Frey A
Europace; 2012 Nov; 14(11):1587-95. PubMed ID: 22455935
[TBL] [Abstract][Full Text] [Related]
11. Autonomic function during closed loop stimulation and fixed rate pacing: heart rate variability analysis from 24-hour Holter recordings.
Quaglione R; Calcagnini G; Censi F; Piccirilli F; Iannucci L; Raveggi M; Biancalana G; Bartolini P
Pacing Clin Electrophysiol; 2010 Mar; 33(3):337-42. PubMed ID: 19889189
[TBL] [Abstract][Full Text] [Related]
12. Heart rate changes during acute mental stress with closed loop stimulation: report on two single-blinded, pacemaker studies.
Chandiramani S; Cohorn LC; Chandiramani S
Pacing Clin Electrophysiol; 2007 Aug; 30(8):976-84. PubMed ID: 17669080
[TBL] [Abstract][Full Text] [Related]
13. Effect of rate-adaptive pacing on performance and physiological parameters during activities of daily living in the elderly: results from the CLEAR (Cylos Responds with Physiologic Rate Changes during Daily Activities) study.
Abi-Samra FM; Singh N; Rosin BL; Dwyer JV; Miller CD;
Europace; 2013 Jun; 15(6):849-56. PubMed ID: 23419655
[TBL] [Abstract][Full Text] [Related]
14. Development of a rate adaptive pacemaker based on the maximum rate-of-rise of right ventricular pressure (RV dP/dtmax).
Bennett T; Sharma A; Sutton R; Camm AJ; Erickson M; Beck R
Pacing Clin Electrophysiol; 1992 Feb; 15(2):219-34. PubMed ID: 1372421
[TBL] [Abstract][Full Text] [Related]
15. Activity controlled cardiac pacemakers during stairwalking: a comparison of accelerometer with vibration guided devices and with sinus rate.
Matula M; Schlegl M; Alt E
Pacing Clin Electrophysiol; 1996 Jul; 19(7):1036-41. PubMed ID: 8823829
[TBL] [Abstract][Full Text] [Related]
16. Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
Danilovic D; Ohm OJ
Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):567-87. PubMed ID: 10234710
[TBL] [Abstract][Full Text] [Related]
17. Closed loop stimulation and accelerometer-based rate adaptation: results of the PROVIDE study.
Coenen M; Malinowski K; Spitzer W; Schuchert A; Schmitz D; Anelli-Monti M; Maier SK; Estlinbaum W; Bauer A; Muehling H; Kalscheur F; Puerner K; Boergel J; Osswald S
Europace; 2008 Mar; 10(3):327-33. PubMed ID: 18272507
[TBL] [Abstract][Full Text] [Related]
18. Closed loop stimulation is effective in improving heart rate and blood pressure response to mental stress: report of a single-chamber pacemaker study in patients with chronotropic incompetent atrial fibrillation.
Proietti R; Manzoni G; Di Biase L; Castelnuovo G; Lombardi L; Fundarò C; Vegliante N; Pietrabissa G; Santangeli P; Canby RA; Sagone A; Viecca M; Natale A
Pacing Clin Electrophysiol; 2012 Aug; 35(8):990-8. PubMed ID: 22680238
[TBL] [Abstract][Full Text] [Related]
19. Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays.
Ovsyshcher I; Zimlichman R; Katz A; Bondy C; Furman S
J Am Coll Cardiol; 1993 Mar; 21(3):761-7. PubMed ID: 8436759
[TBL] [Abstract][Full Text] [Related]
20. Identifying patients for rate responsive atrial pacing: a new method for patient selection and pacemaker programming.
de Cock CC; Kamp O; Meijer A
Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1792-7. PubMed ID: 1279549
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]