These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 12917285)

  • 1. Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions.
    Martins MG; Haiter Neto F; Whaites EJ
    Dentomaxillofac Radiol; 2003 May; 32(3):186-90. PubMed ID: 12917285
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What happens if you delay scanning Digora phosphor storage plates (PSPs) for up to 4 hours?
    Martins MG; Whaites EJ; Ambrosano GM; Haiter Neto F
    Dentomaxillofac Radiol; 2006 May; 35(3):143-6. PubMed ID: 16618845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative study of two digital radiographic storage phosphor systems.
    Oliveira AE; de Almeida SM; Paganini GA; Haiter Neto F; Bóscolo FN
    Braz Dent J; 2000; 11(2):111-6. PubMed ID: 11210259
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of three intra-oral storage phosphor systems using subjective image quality.
    Kitagawa H; Farman AG; Scheetz JP; Brown WP; Lewis J; Benefiel M; Kuroyanagi K
    Dentomaxillofac Radiol; 2000 Sep; 29(5):272-6. PubMed ID: 10980561
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of delayed scanning of storage phosphor plates.
    Akdeniz BG; Gröndahl HG; Kose T
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 May; 99(5):603-7. PubMed ID: 15829885
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography.
    Borg E; Attaelmanan A; Gröndahl HG
    Dentomaxillofac Radiol; 2000 Mar; 29(2):70-5. PubMed ID: 10808218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of delayed scanning of storage phosphor plates on occlusal caries detection.
    Sogur E; Baksi BG; Mert A
    Dentomaxillofac Radiol; 2012 May; 41(4):309-15. PubMed ID: 22282506
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image quality in partially erased DenOptix storage phosphor plates.
    Lopes SL; Cruz AD; Ferreira RI; Bóscolo FN; Almeida SM
    Braz Oral Res; 2008; 22(1):78-83. PubMed ID: 18425250
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates.
    Eskandarloo A; Yousefi A; Soheili S; Ghazikhanloo K; Amini P; Mohammadpoor H
    Open Dent J; 2017; 11():690-700. PubMed ID: 29430262
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of caries detection with four storage phosphor systems and E-speed radiographs.
    Hintze H; Wenzel A; Frydenberg M
    Dentomaxillofac Radiol; 2002 May; 31(3):170-5. PubMed ID: 12058264
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Degradation of storage phosphor images due to scanning delay.
    Akdeniz BG; Gröndahl HG
    Dentomaxillofac Radiol; 2006 Mar; 35(2):74-7. PubMed ID: 16549432
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image quality of two solid-state and three photostimulable phosphor plate digital panoramic systems, and treatment planning of mandibular third molar removal.
    Benediktsdottir IS; Hintze H; Petersen JK; Wenzel A
    Dentomaxillofac Radiol; 2003 Jan; 32(1):39-44. PubMed ID: 12820852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comments on noise and resolution of the DenOptix radiography system.
    Couture RA
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jun; 95(6):746-51. PubMed ID: 12789159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. How many times can we use a phosphor plate? A preliminary study.
    Ergün S; Güneri P; Ilgüy D; Ilgüy M; Boyacioglu H
    Dentomaxillofac Radiol; 2009 Jan; 38(1):42-7. PubMed ID: 19114423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between histological and radiographic caries lesion depth measured in images from four digital radiography systems.
    Jacobsen JH; Hansen B; Wenzel A; Hintze H
    Caries Res; 2004; 38(1):34-8. PubMed ID: 14684975
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems.
    Borg E; Gröndahl HG
    Dentomaxillofac Radiol; 1996 Apr; 25(2):82-8. PubMed ID: 9446978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quality of film-based and digital panoramic radiography.
    Molander B; Gröndahl HG; Ekestubbe A
    Dentomaxillofac Radiol; 2004 Jan; 33(1):32-6. PubMed ID: 15140820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. How does signal fade on photo-stimulable storage phosphor imaging plates when scanned with a delay and what is the effect on image quality?
    Ang DB; Angelopoulos C; Katz JO
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Nov; 102(5):673-9. PubMed ID: 17052646
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems.
    Syriopoulos K; Sanderink GC; Velders XL; van der Stelt PF
    Dentomaxillofac Radiol; 2000 Sep; 29(5):312-8. PubMed ID: 10980568
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experience of Norwegian general dental practitioners with solid state and storage phosphor detectors.
    Wenzel A; Møystad A
    Dentomaxillofac Radiol; 2001 Jul; 30(4):203-8. PubMed ID: 11681481
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.