61 related articles for article (PubMed ID: 12928205)
1. Quantification of mechanical stabilization for the performance of off-pump coronary artery surgery.
Koransky ML; Tavana ML; Yamaguchi A; Kown MH; Miniati DN; Nowlin W; Robbins RC
Heart Surg Forum; 2003; 6(4):224-31. PubMed ID: 12928205
[TBL] [Abstract][Full Text] [Related]
2. Trajectory of coronary motion and its significance in robotic motion cancellation.
Cattin P; Dave H; Grünenfelder J; Szekely G; Turina M; Zünd G
Eur J Cardiothorac Surg; 2004 May; 25(5):786-90. PubMed ID: 15082283
[TBL] [Abstract][Full Text] [Related]
3. Three-dimensional quantification of cardiac surface motion: a newly developed three-dimensional digital motion-capture and reconstruction system for beating heart surgery.
Watanabe T; Omata S; Odamura M; Okada M; Nakamura Y; Yokoyama H
J Thorac Cardiovasc Surg; 2006 Nov; 132(5):1162-71. PubMed ID: 17059939
[TBL] [Abstract][Full Text] [Related]
4. The effects of mechanical cardiac stabilization on left ventricular performance.
Burfeind WR; Duhaylongsod FG; Samuelson D; Leone BJ
Eur J Cardiothorac Surg; 1998 Sep; 14(3):285-9. PubMed ID: 9761439
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer.
Shinn HK; Oh YJ; Kim SH; Lee JH; Lee CS; Kwak YL
Eur J Cardiothorac Surg; 2004 Jun; 25(6):978-84. PubMed ID: 15144998
[TBL] [Abstract][Full Text] [Related]
6. Off-Pump Coronary Bypass through Very Limited Sternotomy.
Naseri E; Sevinç M
Heart Surg Forum; 2003; 6(4):E63-7. PubMed ID: 12928214
[TBL] [Abstract][Full Text] [Related]
7. Safety and efficacy of a novel gel for vascular occlusion in off-pump surgery.
Boodhwani M; Cohn WE; Feng J; Ramlawi B; Mieno S; Schwarz A; Sellke FW
Ann Thorac Surg; 2005 Dec; 80(6):2333-7. PubMed ID: 16305901
[TBL] [Abstract][Full Text] [Related]
8. [Clinical studies in the effect of operative strategies on the hemodynamics in off-pump coronary artery bypass grafting].
Mei J; Wang YQ; Bao CR; Ding FB; Du QR; Xie X; Shen SE
Zhonghua Wai Ke Za Zhi; 2008 Feb; 46(4):241-4. PubMed ID: 18683755
[TBL] [Abstract][Full Text] [Related]
9. Midterm results of beating heart surgery in 1-vessel disease: minimally invasive direct coronary artery bypass versus off-pump coronary artery bypass with full sternotomy.
Vicol C; Nollert G; Mair H; Samuel V; Lim C; Tiftikidis M; Eifert S; Reichart B
Heart Surg Forum; 2003; 6(5):341-4. PubMed ID: 15011666
[TBL] [Abstract][Full Text] [Related]
10. Selective beta-1 receptor blockade further reduces the mechanically stabilized target coronary artery motion during beating heart surgery.
Wakamatsu H; Watanabe T; Sato Y; Takase S; Omata S; Yokoyama H
Innovations (Phila); 2010 Sep; 5(5):349-54. PubMed ID: 22437520
[TBL] [Abstract][Full Text] [Related]
11. Endoscopic exposure and stabilization of posterior and inferior branches using the endo-starfish cardiac positioner and the endo-octopus stabilizer for closed-chest beating heart multivessel CABG: hemodynamic changes in the pig.
Gründeman PF; Budde R; Beck HM; van Boven WJ; Borst C
Circulation; 2003 Sep; 108 Suppl 1():II34-8. PubMed ID: 12970205
[TBL] [Abstract][Full Text] [Related]
12. Magnetic resonance assessment of myocardial perfusion via catheter-based ventricle-coronary vein bypass in porcine myocardial infarction model.
Yoneyama R; Kawase Y; Hoshino K; McGregor J; Mac Neill BD; Lowe HC; Burkhoff D; Boekstegers P; Hajjar RJ; Hayase M
Catheter Cardiovasc Interv; 2006 Jan; 67(1):58-67. PubMed ID: 16345049
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the longitudinal contraction of the ventricle septum in patients undergoing off-pump coronary artery bypass graft surgery by strain rate imaging.
Lee CH; Yang MM; Ho AC; Chen CY; Huang CC; Lui PW; Lin FC
Acta Anaesthesiol Taiwan; 2006 Mar; 44(1):11-8. PubMed ID: 16623402
[TBL] [Abstract][Full Text] [Related]
14. Improved recovery after the endoscopic atraumatic coronary artery bypass procedure compared with sternotomy for off-pump bypass of the left internal thoracic artery to the left anterior descending coronary artery: a case-matched study.
West D; Flather M; Pepper J; Trimlett R; Yap J; De Souza A
Heart Surg Forum; 2004; 7(6):E546-50; discussion E546-50. PubMed ID: 15769683
[TBL] [Abstract][Full Text] [Related]
15. Selective retrograde venous revascularization of the myocardium when PCI or CABG is impossible: investigation in a porcine model.
Møller CH; Nørgaard MA; Gøtze JP; Andersen CB; Olsen NV; Steinbrüchel DA
Heart Surg Forum; 2008; 11(2):E99-104. PubMed ID: 18430666
[TBL] [Abstract][Full Text] [Related]
16. Hybrid coronary revascularization by endoscopic robotic coronary artery bypass grafting on beating heart and stent placement.
Gao C; Yang M; Wu Y; Wang G; Xiao C; Liu H; Lu C
Ann Thorac Surg; 2009 Mar; 87(3):737-41. PubMed ID: 19231382
[TBL] [Abstract][Full Text] [Related]
17. Phasic coronary blood flow pattern during a continuous flow left ventricular assist support.
Ootaki Y; Kamohara K; Akiyama M; Zahr F; Kopcak MW; Dessoffy R; Fukamachi K
Eur J Cardiothorac Surg; 2005 Nov; 28(5):711-6. PubMed ID: 16198117
[TBL] [Abstract][Full Text] [Related]
18. Intracoronary injection of contrast media maps the territory of the coronary artery: an MRI technique for assessing the effects of locally delivered angiogenic therapies.
Carlsson M; Saeed M
Acad Radiol; 2008 Nov; 15(11):1354-9. PubMed ID: 18995187
[TBL] [Abstract][Full Text] [Related]
19. Functional morphology analysis of the left anterior descending coronary artery in EBCT images.
Kakadiaris IA; Santamaría-Pang A; Pednekar A
IEEE Trans Biomed Eng; 2010 Aug; 57(8):1886-96. PubMed ID: 20176530
[TBL] [Abstract][Full Text] [Related]
20. Comparative study of on-pump and off-pump coronary bypass surgery in patients with triple-vessel coronary artery disease.
Chen X; Xu M; Shi HW; Mu XW; Chen ZQ; Qiu ZB
Chin Med J (Engl); 2004 Mar; 117(3):342-6. PubMed ID: 15043770
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]