133 related articles for article (PubMed ID: 12933376)
1. Transesophageal echocardiography-guided placement of internal jugular percutaneous venovenous bypass cannula in orthotopic liver transplantation.
Planinsic RM; Nicolau-Raducu R; Caldwell JC; Aggarwal S; Hilmi I
Anesth Analg; 2003 Sep; 97(3):648-649. PubMed ID: 12933376
[TBL] [Abstract][Full Text] [Related]
2. Morbidity and mortality associated with large-bore percutaneous venovenous bypass cannulation for 312 orthotopic liver transplantations.
Budd JM; Isaac JL; Bennett J; Freeman JW
Liver Transpl; 2001 Apr; 7(4):359-62. PubMed ID: 11303297
[TBL] [Abstract][Full Text] [Related]
3. Percutaneous venovenous bypass in orthotopic liver transplantation.
Washburn WK; Lewis WD; Jenkins RL
Liver Transpl Surg; 1995 Nov; 1(6):377-82. PubMed ID: 9346616
[TBL] [Abstract][Full Text] [Related]
4. Complications associated with percutaneous placement of venous return cannula for venovenous bypass in adult orthotopic liver transplantation.
Sakai T; Planinsic RM; Hilmi IA; Marsh JW
Liver Transpl; 2007 Jul; 13(7):961-5. PubMed ID: 17600351
[TBL] [Abstract][Full Text] [Related]
5. Use of transesophageal echocardiography probe imaging to guide internal jugular vein cannulation.
Sha K; Simokawa M; Kawaguchi M; Iwasaka T; Kurehara K; Kitaguchi K; Furuya H
Anesth Analg; 1998 Nov; 87(5):1032-3. PubMed ID: 9806677
[No Abstract] [Full Text] [Related]
6. Insertion and management of percutaneous veno-venous bypass cannula for liver transplantation: a reference for transplant anesthesiologists.
Sakai T; Gligor S; Diulus J; McAffee R; Wallis Marsh J; Planinsic RM
Clin Transplant; 2010; 24(5):585-91. PubMed ID: 19930407
[TBL] [Abstract][Full Text] [Related]
7. Guiding surgical cannulation of the inferior vena cava with transesophageal echocardiography.
Kirkeby-Garstad I; Tromsdal A; Sellevold OFM; Bjørngaard M; Bjella LK; Berg EM; Karevold A; Haaverstad R; Wahba A; Tjomsland O; Astudillo R; Krogstad A; Stenseth R
Anesth Analg; 2003 May; 96(5):1288-1293. PubMed ID: 12707121
[TBL] [Abstract][Full Text] [Related]
8. Transesophageal Echocardiography Compared to Fluoroscopy for Avalon Bicaval Dual-Lumen Cannula Positioning for Venovenous ECMO.
Hemamalini P; Dutta P; Attawar S
Ann Card Anaesth; 2020; 23(3):283-287. PubMed ID: 32687083
[TBL] [Abstract][Full Text] [Related]
9. Accidental insertion of a percutaneous venovenous cannula into the persistent left superior vena cava of a patient undergoing liver transplantation.
Schreiber KL; Matsusaki T; Bane BC; Bermudez CA; Hilmi IA; Sakai T
Can J Anaesth; 2011 Jul; 58(7):646-649. PubMed ID: 21553167
[TBL] [Abstract][Full Text] [Related]
10. Determination and prediction of the appropriate depth of right internal jugular vein catheterization via the middle approach in adults using transesophageal echocardiography.
Ju H; Sun X; Feng Y
Echocardiography; 2019 Aug; 36(8):1496-1500. PubMed ID: 31287568
[TBL] [Abstract][Full Text] [Related]
11. [Percutaneous femoro-porto-jugular venovenous shunt in orthotopic liver transplantation].
Mayoral V; Sabaté A; Benito C; Camprubí I
Rev Esp Anestesiol Reanim; 1996 Oct; 43(8):294-6. PubMed ID: 9011901
[TBL] [Abstract][Full Text] [Related]
12. Transpharyngeal ultrasonography for cannulation of the internal jugular vein.
Bevilacqua S; Romagnoli S; Ciappi F; Ridolfi N; Codecasa R; Rostagno C; Sorbara C
Anesthesiology; 2005 Apr; 102(4):873-4. PubMed ID: 15791132
[No Abstract] [Full Text] [Related]
13. Confirmation of internal jugular guide wire position utilizing transesophageal echocardiography.
Sawchuk C; Fayad A
Can J Anaesth; 2001; 48(7):688-90. PubMed ID: 11495878
[TBL] [Abstract][Full Text] [Related]
14. A Comprehensive Review of Transesophageal Echocardiography During Orthotopic Liver Transplantation.
Dalia AA; Flores A; Chitilian H; Fitzsimons MG
J Cardiothorac Vasc Anesth; 2018 Aug; 32(4):1815-1824. PubMed ID: 29573952
[TBL] [Abstract][Full Text] [Related]
15. Point-of-care transthoracic echocardiography as an alternative to transesophageal echocardiography to confirm internal jugular guidewire position.
Arellano R; Nurmohamed A; Rumman A; Milne B; Tanzola R
Can J Anaesth; 2012 Jan; 59(1):103-4. PubMed ID: 22033860
[No Abstract] [Full Text] [Related]
16. Carotid-jugular fistula diagnosed by transesophageal echocardiography.
Somerville C; Lucas LA; Biederman RW
Echocardiography; 2012 May; 29(5):E115-8. PubMed ID: 22329828
[TBL] [Abstract][Full Text] [Related]
17. The safety of transesophageal echocardiography in patients undergoing orthotopic liver transplantation.
Markin NW; Sharma A; Grant W; Shillcutt SK
J Cardiothorac Vasc Anesth; 2015; 29(3):588-93. PubMed ID: 25622974
[TBL] [Abstract][Full Text] [Related]
18. Use of percutaneously placed catheters for venovenous bypass in orthotopic liver transplantation.
Manas DM; Gibbs P; Talbot D; Thick MG; Renforth P; Bayly P; Roberts DR
Transplantation; 1996 Jul; 62(1):144-5. PubMed ID: 8693535
[No Abstract] [Full Text] [Related]
19. Five years of experience with percutaneous cannula for establishing venous bypass access in orthotopic liver transplantation.
Frenette L; Cox J; Singer D; Ronderos J; Steele S; Eckhoff D; Bynon S
Transplant Proc; 1996 Oct; 28(5):2974-7. PubMed ID: 8908143
[No Abstract] [Full Text] [Related]
20. Percutaneous technique for venovenous bypass including a heat exchanger is safe and reliable in liver transplantation.
Scholz T; Mathisen O; Bergan A; Osnes S; Innes R; Pedersen T; Aasen AO; Søreide O
Transpl Int; 1997; 10(3):180-4. PubMed ID: 9163856
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]