109 related articles for article (PubMed ID: 12938532)
1. Microbore catheters: keys to successful design and manufacture, Part II.
Kramer HW
Med Device Technol; 2001 Nov; 12(9):16-9. PubMed ID: 12938532
[TBL] [Abstract][Full Text] [Related]
2. Microbore catheters: keys to successful design and manufacture, Part I.
Kramer HW
Med Device Technol; 2001 Oct; 12(8):14-6. PubMed ID: 12938543
[TBL] [Abstract][Full Text] [Related]
3. Tubing extrusion made easier, part I.
Ferrandino M
Med Device Technol; 2004 Oct; 15(8):12-5. PubMed ID: 16225267
[TBL] [Abstract][Full Text] [Related]
4. Tubing extrusion made easier, Part II.
Ferrandino M
Med Device Technol; 2004 Nov; 15(9):20-3. PubMed ID: 16231783
[TBL] [Abstract][Full Text] [Related]
5. Maximising tubing functionality, Part II: Processing guidelines.
Shah TM
Med Device Technol; 2003 Nov; 14(9):29-31. PubMed ID: 14682020
[TBL] [Abstract][Full Text] [Related]
6. Resolving the challenges of producing small-bore tubing.
Eriksson J
Med Device Technol; 2005 May; 16(4):14-7. PubMed ID: 15941192
[TBL] [Abstract][Full Text] [Related]
7. Kinking of medical tubes.
Ingles D
Med Device Technol; 2004 May; 15(4):12-3. PubMed ID: 15303556
[TBL] [Abstract][Full Text] [Related]
8. Ultraprecision machining.
Dinesen PG; Rasmussen JB; Holme C; Johansen M
Med Device Technol; 2004 May; 15(4):48. PubMed ID: 15303566
[TBL] [Abstract][Full Text] [Related]
9. Manufacturing close tolerance medical tubing.
Sparacino C
Med Device Technol; 2006 Oct; 17(8):10-2. PubMed ID: 17153365
[TBL] [Abstract][Full Text] [Related]
10. Maximising tubing functionality, Part I: Proper selection of resins.
Shah TM
Med Device Technol; 2003 Oct; 14(8):14-8. PubMed ID: 14603713
[TBL] [Abstract][Full Text] [Related]
11. Packaging issues: avoiding delamination.
Hall R
Med Device Technol; 2005 Oct; 16(8):32-4, 36. PubMed ID: 16355970
[TBL] [Abstract][Full Text] [Related]
12. Analysis software can put surgical precision into medical device design.
Jain S
Med Device Technol; 2005 Nov; 16(9):24-6. PubMed ID: 16438445
[TBL] [Abstract][Full Text] [Related]
13. Metal shafts: designs to meet the required performance.
Farrissey L
Med Device Technol; 2004 Dec; 15(10):26-9. PubMed ID: 16225281
[TBL] [Abstract][Full Text] [Related]
14. Quality control of inkjet technology for DNA microarray fabrication.
Pierik A; Dijksman F; Raaijmakers A; Wismans T; Stapert H
Biotechnol J; 2008 Dec; 3(12):1581-90. PubMed ID: 19039779
[TBL] [Abstract][Full Text] [Related]
15. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
Liu F; Jin Z; Roberts P; Grigoris P
J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
[TBL] [Abstract][Full Text] [Related]
16. Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery.
Tercero C; Ikeda S; Uchiyama T; Fukuda T; Arai F; Okada Y; Ono Y; Hattori R; Yamamoto T; Negoro M; Takahashi I
Int J Med Robot; 2007 Mar; 3():52-8. PubMed ID: 17441026
[TBL] [Abstract][Full Text] [Related]
17. The fluid property dependency on micro-fluidic characteristics in the deposition process for microfabrication.
Chau SW; Hsu KL; Chen SC; Liou TM; Shih KC
Biosens Bioelectron; 2004 Jul; 20(1):133-8. PubMed ID: 15142586
[TBL] [Abstract][Full Text] [Related]
18. Laser micromachining.
Kearsley A
Med Device Technol; 2003 Mar; 14(2):18-9. PubMed ID: 12698693
[TBL] [Abstract][Full Text] [Related]
19. Catheter hole making.
Thompson S
Med Device Technol; 2007; 18(7):26-7. PubMed ID: 18075131
[TBL] [Abstract][Full Text] [Related]
20. [Microcatheter in neuroradiology].
Haindl H; Schumacher M
Rofo; 2006 Jul; 178(7):688-92. PubMed ID: 16761213
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]