149 related articles for article (PubMed ID: 12945663)
21. A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
Yaftian MR; Rayati S; Emadi D; Matt D
Anal Sci; 2006 Aug; 22(8):1075-8. PubMed ID: 16896245
[TBL] [Abstract][Full Text] [Related]
22. Anion recognition using newly synthesized hydrogen bonding disubstituted phenylhydrazone-based receptors: poly(vinyl chloride)-based sensor for acetate.
Gupta VK; Goyal RN; Sharma RA
Talanta; 2008 Aug; 76(4):859-64. PubMed ID: 18656670
[TBL] [Abstract][Full Text] [Related]
23. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
[TBL] [Abstract][Full Text] [Related]
24. Salicylate-selective electrodes based on AI(III) and Sn(IV) salophens.
Shahrokhian S; Amini MK; Kia R; Tangestaninejad S
Anal Chem; 2000 Mar; 72(5):956-62. PubMed ID: 10739198
[TBL] [Abstract][Full Text] [Related]
25. Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex.
Ganjali MR; Norouzi P; Gol-Mohammadi M; Mizani F; Poursaberi T; Salavati-Niasari M; Shamsipur M; Hosseini M; Javanbakht M
Ann Chim; 2003; 93(7-8):679-90. PubMed ID: 12940601
[TBL] [Abstract][Full Text] [Related]
26. Poly(vinyl chloride)-based macrocyclic membrane sensors for magnesium.
Baniwal S; Chandra S; Panwar A; Singh AK
Talanta; 1999 Oct; 50(3):499-508. PubMed ID: 18967740
[TBL] [Abstract][Full Text] [Related]
27. Tetrabenzyl pyrophosphate as a new class of neutral carrier responsive to lead ion.
Xu D; Katsu T
Talanta; 2000 Feb; 51(2):365-71. PubMed ID: 18967868
[TBL] [Abstract][Full Text] [Related]
28. Lead(II)-selective electrode based on phenyl disulfide.
Abbaspour A; Khajeh B
Anal Sci; 2002 Sep; 18(9):987-91. PubMed ID: 12243415
[TBL] [Abstract][Full Text] [Related]
29. Ni(II) selective sensors based on Schiff bases membranes in poly(vinyl chloride).
Gupta VK; Singh AK; Pal MK
Anal Chim Acta; 2008 Aug; 624(2):223-31. PubMed ID: 18706328
[TBL] [Abstract][Full Text] [Related]
30. Ion-selective electrode for the determination of prenalterol.
Khalil S; El-Ries MA
Talanta; 2003 May; 59(6):1259-66. PubMed ID: 18969017
[TBL] [Abstract][Full Text] [Related]
31. A lead(II)-selective PVC membrane based on a Schiff base complex of N,N'-bis(salicylidene)-2,6-pyridinediamine.
Jeong T; Lee HK; Jeong DC; Jeon S
Talanta; 2005 Jan; 65(2):543-8. PubMed ID: 18969833
[TBL] [Abstract][Full Text] [Related]
32. New cadmium(II)-selective electrode based on a tetraazacyclohexadeca macrocyclic ionophore.
Singh AK; Saxena P; Singh R
Anal Sci; 2005 Feb; 21(2):179-81. PubMed ID: 15732481
[TBL] [Abstract][Full Text] [Related]
33. Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore.
Ghaemi A; Tavakkoli H; Mombeni T
Mater Sci Eng C Mater Biol Appl; 2014 May; 38():186-91. PubMed ID: 24656367
[TBL] [Abstract][Full Text] [Related]
34. Potentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.
Mazloum Ardakani M; Dehghani H; Jalayer M; Zare HR
Anal Sci; 2004 Dec; 20(12):1667-72. PubMed ID: 15636513
[TBL] [Abstract][Full Text] [Related]
35. Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples.
Arvand M; Asadollahzadeh SA
Talanta; 2008 May; 75(4):1046-54. PubMed ID: 18585182
[TBL] [Abstract][Full Text] [Related]
36. Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base.
Mashhadizadeh MH; Sheikhshoaie I
Talanta; 2003 May; 60(1):73-80. PubMed ID: 18969027
[TBL] [Abstract][Full Text] [Related]
37. A novel thiocyanate-selective electrode based on a zinc-phthalocyanine complex.
Xu WJ; Chai YQ; Yuan R; Liu SL
Anal Bioanal Chem; 2006 Jul; 385(5):926-30. PubMed ID: 16791573
[TBL] [Abstract][Full Text] [Related]
38. A novel salicylate-selective electrode based on a Sn(IV) complex of salicylal-imino acid Schiff base.
Xu L; Yuan R; Chai YQ; Wang XL
Anal Bioanal Chem; 2005 Feb; 381(3):781-7. PubMed ID: 15668810
[TBL] [Abstract][Full Text] [Related]
39. Fentanyl-selective polymeric membrane electrode.
Peng LJ; Wen ML; Yao Y
Pharmazie; 2001 Oct; 56(10):780-2. PubMed ID: 11683122
[TBL] [Abstract][Full Text] [Related]
40. A highly selective and sensitive disposable carbon composite PVC-based membrane for determination of lead ion in environmental samples.
Abbaspour A; Mirahmadi E; Khalafi-Nejad A; Babamohammadi S
J Hazard Mater; 2010 Feb; 174(1-3):656-61. PubMed ID: 19828247
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]