These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
137 related articles for article (PubMed ID: 12946664)
21. Comparative evaluation of different miniplates for internal fixation of mandible fractures using finite element analysis. Arbag H; Korkmaz HH; Ozturk K; Uyar Y J Oral Maxillofac Surg; 2008 Jun; 66(6):1225-32. PubMed ID: 18486788 [TBL] [Abstract][Full Text] [Related]
22. Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study. Chritah A; Lazow SK; Berger JR J Oral Maxillofac Surg; 2005 Dec; 63(12):1737-41. PubMed ID: 16297694 [TBL] [Abstract][Full Text] [Related]
23. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures. Cox T; Kohn MW; Impelluso T J Oral Maxillofac Surg; 2003 Apr; 61(4):481-7; discussion 487-8. PubMed ID: 12684967 [TBL] [Abstract][Full Text] [Related]
24. A comparative study of intermaxillary fixation screws and noncompression miniplates in the treatment of mandibular fractures: a prospective clinical study. Anslem O; Eyituoyo O; Olabode OV; Ademola OA; Adesina AO Oral Maxillofac Surg; 2017 Jun; 21(2):233-240. PubMed ID: 28386782 [TBL] [Abstract][Full Text] [Related]
25. Assessment of compression and strength of divergent screws mounted on miniplates for fixation of mandibular fractures: an in vitro experimental study. Jafarian M; Pourdanesh F; Esmaeelinejad M; Dehghani N; Aghdashi F; Tabrizi R Br J Oral Maxillofac Surg; 2015 Sep; 53(7):613-7. PubMed ID: 25921364 [TBL] [Abstract][Full Text] [Related]
26. Treatment of mandibular-condylar fractures. Krenkel C Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):127-55. PubMed ID: 11905341 [TBL] [Abstract][Full Text] [Related]
28. Mandibular fracture reduction without intraoperative intermaxillary fixation: a technique using two modified reduction forceps. Shinohara EH; Mitsuda ST; Miyagusko JM; Horikawa FK J Contemp Dent Pract; 2006 Feb; 7(1):150-6. PubMed ID: 16491158 [TBL] [Abstract][Full Text] [Related]
29. Comparative analysis of the threaded and tapered locking reconstruction plates. Coletti DP; Caccamese JF; Norby C; Edwards S; von Fraunhofer JA J Oral Maxillofac Surg; 2007 Dec; 65(12):2587-93. PubMed ID: 18022489 [No Abstract] [Full Text] [Related]
30. A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process. Wagner A; Krach W; Schicho K; Undt G; Ploder O; Ewers R Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2002 Dec; 94(6):678-86. PubMed ID: 12464890 [TBL] [Abstract][Full Text] [Related]
32. Three-dimensional v/s standard titanium miniplate fixation in the management of mandibular fractures--a randomized clinical study. Sehgal S; Ramanujam L; Prasad K; Krishnappa R J Craniomaxillofac Surg; 2014 Oct; 42(7):1292-9. PubMed ID: 24780350 [TBL] [Abstract][Full Text] [Related]
33. Assessment of compression and strength of divergent screws mounted on miniplates and dynamic compression plate in fixation of mandibular body fractures: an in vitro study. Aghdashi F; Forouzmehr A; Nahvi G; Tabrizi R; Jafarian M; Majdi S Br J Oral Maxillofac Surg; 2020 Dec; 58(10):e260-e264. PubMed ID: 32811725 [TBL] [Abstract][Full Text] [Related]
34. Comparative evaluation of ten different condylar base fracture osteosynthesis techniques. Pilling E; Eckelt U; Loukota R; Schneider K; Stadlinger B Br J Oral Maxillofac Surg; 2010 Oct; 48(7):527-31. PubMed ID: 19853981 [TBL] [Abstract][Full Text] [Related]
35. A comparative study between traditional fixation with miniplates and modified lag screws for the treatment of mandibular fractures. García Carricondo AR; Quesada Bravo FJ; Espín Gálvez F; Parrón Carreño T; Alarcón Rodriguez R Clin Oral Investig; 2018 Apr; 22(3):1503-1511. PubMed ID: 29038962 [TBL] [Abstract][Full Text] [Related]
36. Management of mandibular body fractures. Kushner GM; Alpert B Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):61-76. PubMed ID: 11905345 [No Abstract] [Full Text] [Related]
37. In vitro study of a modified sagittal split osteotomy fixation technique of the mandible: a mechanical test. Sonego CL; Scheffer MAR; Chagas Júnior OL; Vetromilla BM; Fernandes LP; Ozkomur A; Silva Júnior AN; Miguens Júnior SAQ; Hernandez PAG Int J Oral Maxillofac Surg; 2018 Oct; 47(10):1330-1335. PubMed ID: 29655819 [TBL] [Abstract][Full Text] [Related]
39. The need for rigid fixation of combined parasymphyseal and bilateral subcondylar fractures. Wheatley MJ; Meltzer TR J Craniomaxillofac Trauma; 1997; 3(1):46-51. PubMed ID: 11951271 [TBL] [Abstract][Full Text] [Related]
40. Finite element modeling for development and optimization of a bone plate for mandibular fracture in dogs. Freitas EP; Rahal SC; Gioso MA; Vulcano LC; Shimano AC; da Silva JV; Noritomi PY; El Warrak AO J Vet Dent; 2010; 27(4):212-21. PubMed ID: 21322428 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]