These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 12954261)

  • 1. Changes in tendon strength after partial cut and effects of running peripheral sutures.
    Tan J; Wang B; Tan B; Xu Y; Tang JB
    J Hand Surg Br; 2003 Oct; 28(5):478-82. PubMed ID: 12954261
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Repairs of partial oblique tendon injuries: a biomechanical evaluation.
    Tan J; Ming L; Jia ZJ; Tang JB
    J Hand Surg Br; 2004 Aug; 29(4):381-5. PubMed ID: 15234505
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Increased suture embedment in tendons: an effective method to improve repair strength.
    Wang B; Tang JB
    J Hand Surg Br; 2002 Aug; 27(4):333-6. PubMed ID: 12162971
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons.
    Mao WF; Wu YF
    J Vis Exp; 2020 Jun; (160):. PubMed ID: 32568228
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of flexor tendon repair techniques.
    Tang JB; Wang B; Chen F; Pan CZ; Xie RG
    Clin Orthop Relat Res; 2001 May; (386):252-9. PubMed ID: 11347844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of direction of tendon lacerations on strength of tendon repairs.
    Tan J; Wang B; Xu Y; Tang JB
    J Hand Surg Am; 2003 Mar; 28(2):237-42. PubMed ID: 12671854
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Embedded cross-stitch suture: an alternative to current cross-stitch peripheral suture.
    Wang B; Tang JB
    J Hand Surg Br; 2003 Oct; 28(5):471-4. PubMed ID: 12954259
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of a Q Suture Technique on Resistance to Gap Formation and Tensile Strength of Repaired Tendons: An Ex Vivo Mechanical Study.
    Mao WF; Wu YF
    J Hand Surg Am; 2020 Mar; 45(3):258.e1-258.e7. PubMed ID: 31451319
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biomechanical study of Tang's multiple locking techniques for flexor tendon repair.
    Tang JB; Pan CZ; Xie RG; Chen F
    Chir Main; 1999; 18(4):254-60. PubMed ID: 10855328
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of core suture purchase length on strength of four-strand tendon repairs.
    Cao Y; Zhu B; Xie RG; Tang JB
    J Hand Surg Am; 2006 Jan; 31(1):107-12. PubMed ID: 16443114
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Symmetric Peripheral Running Sutures are Superior to Asymmetric Peripheral Running Sutures for Increasing the Tendon Strength in Flexor Tendon Repair.
    Takeuchi N; Okada T; Kozono N; Shimoto T; Higaki H; Iwamoto Y
    J Hand Surg Asian Pac Vol; 2017 Jun; 22(2):208-213. PubMed ID: 28506161
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An Exploratory Study Using Semi-Tabular Plate in Zone II Flexor Tendon Repair.
    Wong YR; Jais ISM; Chang MK; Lim BH; Tay SC
    J Hand Surg Asian Pac Vol; 2018 Dec; 23(4):547-553. PubMed ID: 30428798
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of four methods of flexor tendon repair for postoperative active mobilization.
    Tang JB; Gu YT; Rice K; Chen F; Pan CZ
    Plast Reconstr Surg; 2001 Mar; 107(3):742-9. PubMed ID: 11304600
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flexor tendon repair with barbed suture: an experimental study.
    Sato M; Matsumura H; Gondo M; Shimada K; Watanabe K
    Eur J Orthop Surg Traumatol; 2014 Dec; 24(8):1421-4. PubMed ID: 24121796
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of locking configurations for tendon repair.
    Xie RG; Tang JB
    J Hand Surg Am; 2005 May; 30(3):461-5. PubMed ID: 15925152
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a new 4-strand flexor tendon repair in a cadaveric porcine model.
    Manchio JV; Shashikant MP; Shrivastava A; Weinzweig J; Vernadakis AJ
    J Hand Surg Am; 2009 Jan; 34(1):102-7. PubMed ID: 19058923
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application.
    Chen J; Wang K; Katirai F; Chen Z
    J Orthop Surg Res; 2014 Dec; 9():136. PubMed ID: 25551285
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Treatment of partial lacerations in flexor tendons by trimming. A biomechanical in vitro study.
    Erhard L; Zobitz ME; Zhao C; Amadio PC; An KN
    J Bone Joint Surg Am; 2002 Jun; 84(6):1006-12. PubMed ID: 12063336
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of a Q Suture Technique as a Core Suture on Resistance to Gap Formation and Tensile Strength in an Ex Vivo Porcine Flexor Tendon Model.
    Wu YF
    J Hand Surg Am; 2024 Apr; 49(4):381.e1-381.e8. PubMed ID: 36180372
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flexor tendons repair: effect of core sutures caliber with increased number of suture strands and peripheral sutures. A sheep model.
    Uslu M; Isik C; Ozsahin M; Ozkan A; Yasar M; Orhan Z; Erkan Inanmaz M; Sarman H
    Orthop Traumatol Surg Res; 2014 Oct; 100(6):611-6. PubMed ID: 25130761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.