97 related articles for article (PubMed ID: 12955537)
1. Unreamed tibia nail (UTN) bending: case report and problem solution.
Kelsch G; Kelsch R; Ulrich C
Arch Orthop Trauma Surg; 2003 Dec; 123(10):558-62. PubMed ID: 12955537
[TBL] [Abstract][Full Text] [Related]
2. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
Vallier HA; Cureton BA; Patterson BM
J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
[TBL] [Abstract][Full Text] [Related]
3. [Initial experiences with the unreamed AO tibial nail].
Melcher GA; Ryf C; Bereiter H; Leutenegger A; Rüedi T
Helv Chir Acta; 1993 Mar; 59(4):669-71. PubMed ID: 8473188
[TBL] [Abstract][Full Text] [Related]
4. The AO 8mm solid tibial nail is not defunct.
Sehat K; Aladin A; Calthorpe D
Injury; 2007 Nov; 38(11):1300-4. PubMed ID: 17884052
[TBL] [Abstract][Full Text] [Related]
5. Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the Unreamed Tibia Nail.
Veen EJ; Ettema HB; Zuurmond RG; Mostert AK
Injury; 2011 Oct; 42(10):1049-52. PubMed ID: 21549378
[TBL] [Abstract][Full Text] [Related]
6. [Initial results with the unreamed AO tibial nail].
Melcher GA; Ryf C; Bereiter H; Leutenegger A; Rüedi T
Schweiz Med Wochenschr; 1993 Apr; 123(13):587-8. PubMed ID: 8480153
[TBL] [Abstract][Full Text] [Related]
7. [Segmental tibia fractures: a critical retrospective analysis of 49 cases].
Bonnevialle P; Cariven P; Bonnevialle N; Mansat P; Martinel V; Verhaeghe L; Mansat M
Rev Chir Orthop Reparatrice Appar Mot; 2003 Sep; 89(5):423-32. PubMed ID: 13679742
[TBL] [Abstract][Full Text] [Related]
8. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails--a biomechanical study using a distal tibia fracture model.
Schüller M; Weninger P; Tschegg E; Jamek M; Redl H; Stanzl-Tschegg S
J Trauma; 2009 May; 66(5):1391-7. PubMed ID: 19430244
[TBL] [Abstract][Full Text] [Related]
9. Removal of broken distal intramedullary nail with a simple method: a case report.
Georgilas I; Mouzopoulos G; Neila C; Morakis E; Tzurbakis M
Arch Orthop Trauma Surg; 2009 Feb; 129(2):203-5. PubMed ID: 18297295
[TBL] [Abstract][Full Text] [Related]
10. [A simple and rapid method for removal of broken unreamed tibial nails].
Schmidgen A; Naumann O; Wentzensen A
Unfallchirurg; 1999 Dec; 102(12):975-8. PubMed ID: 10643398
[TBL] [Abstract][Full Text] [Related]
11. Treatment of type IIIA open fractures of tibial shaft with Ilizarov external fixator versus unreamed tibial nailing.
Inan M; Halici M; Ayan I; Tuncel M; Karaoglu S
Arch Orthop Trauma Surg; 2007 Oct; 127(8):617-23. PubMed ID: 17476515
[TBL] [Abstract][Full Text] [Related]
12. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN).
Hansen M; Mehler D; Hessmann MH; Blum J; Rommens PM
J Orthop Trauma; 2007; 21(10):701-9. PubMed ID: 17986887
[TBL] [Abstract][Full Text] [Related]
13. [Treatment of complex fractures of the ankle and their sequellae using trans-plantar intramedullary nailing].
Gagneux E; Gerard F; Garbuio P; Vichard P
Acta Orthop Belg; 1997 Dec; 63(4):294-304. PubMed ID: 9479784
[TBL] [Abstract][Full Text] [Related]
14. [Intramedullary nailing of lower leg fractures with minimal soft tissue injuries].
Ruchholtz S; Nast-Kolb D; Schweiberer L
Orthopade; 1996 Jun; 25(3):197-206. PubMed ID: 8766658
[TBL] [Abstract][Full Text] [Related]
15. A multicentre case series of tibia fractures treated with the Expert Tibia Nail (ETN).
Attal R; Hansen M; Kirjavainen M; Bail H; Hammer TO; Rosenberger R; Höntzsch D; Rommens PM
Arch Orthop Trauma Surg; 2012 Jul; 132(7):975-84. PubMed ID: 22431141
[TBL] [Abstract][Full Text] [Related]
16. [Reducing the risk of infection by use of an unreamed intramedullary nail in open tibial fractures].
Ketterl R; Leitner A; Wittwer W
Zentralbl Chir; 1994; 119(8):549-55. PubMed ID: 7975944
[TBL] [Abstract][Full Text] [Related]
17. Angle stable locking nails versus conventionally locked intramedullary nails in proximal tibial shaft fractures: a biomechanical study.
Thelen S; Betsch M; Grassmann JP; Spoor V; Eichler C; Koebke J; Windolf J; Hakimi M; Wild M
Arch Orthop Trauma Surg; 2012 Jan; 132(1):57-63. PubMed ID: 21877127
[TBL] [Abstract][Full Text] [Related]
18. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
[TBL] [Abstract][Full Text] [Related]
19. Removal of a bent intramedullary nail in lower extremity: report of two cases and review of removal techniques.
Kose O; Guler F; Kilicaslan OF; May H; Yuksel HY
Arch Orthop Trauma Surg; 2016 Feb; 136(2):195-202. PubMed ID: 26541577
[TBL] [Abstract][Full Text] [Related]
20. Computational comparison of reamed versus unreamed intramedullary tibial nails.
Gómez-Benito MJ; Fornells P; García-Aznar JM; Seral B; Seral-Iñnigo F; Doblaré M
J Orthop Res; 2007 Feb; 25(2):191-200. PubMed ID: 17089377
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]