151 related articles for article (PubMed ID: 12960951)
1. [Comparison of shielding calculations for diagnostic X-ray equipment].
Noto K; Sota T; Koshida K; Suzuki S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Aug; 59(8):976-83. PubMed ID: 12960951
[TBL] [Abstract][Full Text] [Related]
2. [Measurement of environmental radiation in X-ray room with passive integrating dosimeter].
Iida H; Horii J; Chabatake M; Mizushima T; Kobayashi I
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 May; 61(5):709-17. PubMed ID: 15915145
[TBL] [Abstract][Full Text] [Related]
3. [Effective dose transmission of diagnostic X-rays through concrete and lead shields].
Kato H
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Aug; 59(8):965-75. PubMed ID: 12960950
[TBL] [Abstract][Full Text] [Related]
4. Comparison of the CT scatter fractions provided in NCRP Report No. 147 to scanner-specific scatter fractions and the consequences for calculated barrier thickness.
Larson SC; Goodsitt MM; Christodoulou EG; Larson LS
Health Phys; 2007 Aug; 93(2):165-70. PubMed ID: 17622822
[TBL] [Abstract][Full Text] [Related]
5. Effective dose as a limiting quantity for the evaluation of primary barriers for diagnostic x-ray facilities.
Okunade AA
Health Phys; 2005 Nov; 89(5 Suppl):S100-16. PubMed ID: 16224257
[TBL] [Abstract][Full Text] [Related]
6. A new shielding calculation method for X-ray computed tomography regarding scattered radiation.
Watanabe H; Noto K; Shohji T; Ogawa Y; Fujibuchi T; Yamaguchi I; Hiraki H; Kida T; Sasanuma K; Katsunuma Y; Nakano T; Horitsugi G; Hosono M
Radiol Phys Technol; 2017 Jun; 10(2):213-226. PubMed ID: 28025782
[TBL] [Abstract][Full Text] [Related]
7. Secondary shielding barriers for diagnostic x-ray facilities: scatter and leakage revisited.
Simpkin DJ; Dixon RL
Health Phys; 1998 Mar; 74(3):350-65. PubMed ID: 9482601
[TBL] [Abstract][Full Text] [Related]
8. Technical note: room shielding requirements in diagnostic radiology.
Casey M
Br J Radiol; 1994 Mar; 67(795):296-8. PubMed ID: 8131004
[TBL] [Abstract][Full Text] [Related]
9. Comparison of computed tomography shielding design methods using RadShield.
DeLorenzo MC; Yang K; Wu DH; Wang W; Rutel IB
J Radiol Prot; 2017 Jun; 37(2):492-505. PubMed ID: 28397710
[TBL] [Abstract][Full Text] [Related]
10. Surveyed data for structural shielding calculations of radiographic x-ray installations in Taiwan.
Chen TR; Tyan YS; Chu CH; Wu MC; Tung CJ
Health Phys; 2013 May; 104(5 Suppl 2):S60-7. PubMed ID: 23528275
[TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo model for retrospective analysis of shield design in a diagnostic x-ray room.
Metzger R; Richardson R; Van Riper KA
Health Phys; 1993 Aug; 65(2):164-71. PubMed ID: 8330963
[TBL] [Abstract][Full Text] [Related]
12. Radiation protection in dental X-ray surgeries--still rooms for improvement.
Hart G; Dugdale M
Br Dent J; 2013 Mar; 214(6):E16. PubMed ID: 23519002
[TBL] [Abstract][Full Text] [Related]
13. Establishment of scatter factors for use in shielding calculations and risk assessment for computed tomography facilities.
Wallace H; Martin CJ; Sutton DG; Peet D; Williams JR
J Radiol Prot; 2012 Mar; 32(1):39-50. PubMed ID: 22327169
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of transmission data of diagnostic X rays through concrete using Monte Carlo simulation.
Noto K; Koshida K; Iida H; Fukuda A
Radiat Prot Dosimetry; 2009 Feb; 133(3):144-52. PubMed ID: 19307234
[TBL] [Abstract][Full Text] [Related]
15. Recent history of the shielding of medical x-ray imaging facilities.
Archer BR
Health Phys; 2005 Jun; 88(6):579-86. PubMed ID: 15891455
[TBL] [Abstract][Full Text] [Related]
16. Excessive leakage radiation measured on two mobile X-ray units due to the methodology used by the manufacturer to calculate and specify the required tube shielding.
Tsalafoutas IA
Br J Radiol; 2006 Feb; 79(938):162-4. PubMed ID: 16489198
[TBL] [Abstract][Full Text] [Related]
17. Structural Shielding Evaluation: A Case Study of the Radiography Room of a Rural Hospital in Jos, Nigeria.
Yusuf SD; Lumbi WL; Umar I; Loko ZA; Mundi AA
J Med Imaging Radiat Sci; 2020 Jun; 51(2):331-341. PubMed ID: 32284235
[TBL] [Abstract][Full Text] [Related]
18. [Place of the radiation safety officer in the implementation of the ALARA principle through European directive 97-43 items].
Mozziconacci JG; Ayivi J; Loat A; Ifergan J; Mourbrun M; Drevet B
J Radiol; 2005 May; 86(5 Pt 1):455-60. PubMed ID: 16114200
[TBL] [Abstract][Full Text] [Related]
19. [Q&A of radiation protection in diagnostic X-ray room (outline of the version fiscal year 2011)].
Japan Industries Association of Radiological Systems, Facility Design Group Standardization Committee
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2011; 67(12):1644-6. PubMed ID: 22186211
[No Abstract] [Full Text] [Related]
20. [Hygienic requirement for calculation the protection, radiation control and control of the exploitation parameters for the X-ray equipment].
Ermolina EP; Pertsov VA
Med Tekh; 2003; (5):9-11. PubMed ID: 14603842
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]