BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 12974496)

  • 1. Modelling drainage of the precorneal tear film after a blink.
    Braun RJ; Fitt AD
    Math Med Biol; 2003 Mar; 20(1):1-28. PubMed ID: 12974496
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A model for wetting and evaporation of a post-blink precorneal tear film.
    Winter KN; Anderson DM; Braun RJ
    Math Med Biol; 2010 Sep; 27(3):211-25. PubMed ID: 19861501
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single-equation models for the tear film in a blink cycle: realistic lid motion.
    Heryudono A; Braun RJ; Driscoll TA; Maki KL; Cook LP; King-Smith PE
    Math Med Biol; 2007 Dec; 24(4):347-77. PubMed ID: 17947253
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thinning rate of the precorneal and prelens tear films.
    Nichols JJ; Mitchell GL; King-Smith PE
    Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2353-61. PubMed ID: 15980222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The precorneal tear film as a fluid shell: the effect of blinking and saccades on tear film distribution and dynamics.
    Yokoi N; Bron AJ; Georgiev GA
    Ocul Surf; 2014 Oct; 12(4):252-66. PubMed ID: 25284771
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamics of tear film deposition and draining.
    Jones MB; Please CP; McElwain DL; Fulford GR; Roberts AP; Collins MJ
    Math Med Biol; 2005 Sep; 22(3):265-88. PubMed ID: 16014344
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamics and function of the tear film in relation to the blink cycle.
    Braun RJ; King-Smith PE; Begley CG; Li L; Gewecke NR
    Prog Retin Eye Res; 2015 Mar; 45():132-64. PubMed ID: 25479602
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evidence for the major contribution of evaporation to tear film thinning between blinks.
    Kimball SH; King-Smith PE; Nichols JJ
    Invest Ophthalmol Vis Sci; 2010 Dec; 51(12):6294-7. PubMed ID: 20688724
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of the lipid layer on tear film behaviour.
    Jones MB; McElwain DL; Fulford GR; Collins MJ; Roberts AP
    Bull Math Biol; 2006 Aug; 68(6):1355-81. PubMed ID: 17149821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The brilliant beauty of the eye: light reflex from the cornea and tear film.
    Goto E
    Cornea; 2006 Dec; 25(10 Suppl 1):S78-81. PubMed ID: 17001200
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of a novel interferometric method to investigate the relation between lipid layer thickness and tear film thinning.
    King-Smith PE; Hinel EA; Nichols JJ
    Invest Ophthalmol Vis Sci; 2010 May; 51(5):2418-23. PubMed ID: 20019370
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaporation-driven instability of the precorneal tear film.
    Peng CC; Cerretani C; Braun RJ; Radke CJ
    Adv Colloid Interface Sci; 2014 Apr; 206():250-64. PubMed ID: 23842140
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The influence of a lipid reservoir on the tear film formation.
    Maki KL; Braun RJ; Barron GA
    Math Med Biol; 2020 Sep; 37(2):363-388. PubMed ID: 31990037
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Longitudinal analysis of precorneal tear film rupture patterns.
    Bitton E; Lovasik JV
    Adv Exp Med Biol; 1998; 438():381-9. PubMed ID: 9634911
    [No Abstract]   [Full Text] [Related]  

  • 15. Effects of Tear Film Lipid Layer Thickness and Blinking Pattern on Tear Film Instability After Corneal Refractive Surgery.
    Chen Q; Li M; Yuan Y; Me R; Yu Y; Shi G; Wang X; Ke B
    Cornea; 2017 Jul; 36(7):810-815. PubMed ID: 28410354
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Black-line formation and the "perched" human tear film.
    Miller KL; Polse KA; Radke CJ
    Curr Eye Res; 2002 Sep; 25(3):155-62. PubMed ID: 12607185
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Gravity, blink rate, and lacrimal drainage capacity.
    Sahlin S; Chen E
    Am J Ophthalmol; 1997 Dec; 124(6):758-64. PubMed ID: 9402821
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modelling the evaporation of a tear film over a contact lens.
    Talbott K; Xu A; Anderson DM; Seshaiyer P
    Math Med Biol; 2015 Jun; 32(2):209-38. PubMed ID: 24521538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The thickness of the human precorneal tear film: evidence from reflection spectra.
    King-Smith PE; Fink BA; Fogt N; Nichols KK; Hill RM; Wilson GS
    Invest Ophthalmol Vis Sci; 2000 Oct; 41(11):3348-59. PubMed ID: 11006224
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tear film physiology.
    Holly FJ
    Am J Optom Physiol Opt; 1980 Apr; 57(4):252-7. PubMed ID: 7386586
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.