3. Delivering CPAP with a siemens Servo 900B ventilator. Winter RJ Intensive Care Med; 1990; 16(2):138-9. PubMed ID: 2185288 [No Abstract] [Full Text] [Related]
4. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing. Aerts JG; van den Berg B; Bogaard JM Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760 [TBL] [Abstract][Full Text] [Related]
5. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure. Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128 [TBL] [Abstract][Full Text] [Related]
6. Comparison of NAD 6000 and servo 900C ventilators in an infant lung model. Stayer SA; Bent ST; Campos CJ; Skjonsby BS; Andropoulos DB Anesth Analg; 2000 Feb; 90(2):315-21. PubMed ID: 10648313 [TBL] [Abstract][Full Text] [Related]
7. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Patel RG; Petrini MF Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020 [TBL] [Abstract][Full Text] [Related]
8. Prolonged "phantom" square wave capnograph tracing after patient disconnection or extubation. Potential hazard associated with the Siemens Servo 900c ventilator. Ginosar Y; Baranov D Anesthesiology; 1997 Mar; 86(3):729-35. PubMed ID: 9066340 [TBL] [Abstract][Full Text] [Related]
9. CPAP with a Siemens Servo 900C ventilator during weaning in infants. Radermacher P; Breulmann M; Felber HJ; Santak B Intensive Care Med; 1991; 17(3):189. PubMed ID: 2071772 [No Abstract] [Full Text] [Related]
10. Failure of an infant Laerdal self-inflating resuscitator due to misassembly. Fahey D Anaesth Intensive Care; 2009 May; 37(3):500-1. PubMed ID: 19499878 [No Abstract] [Full Text] [Related]
11. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
12. Malfunction of Servo ventilator and auto-PEEP. Sun KO Anaesth Intensive Care; 1993 Apr; 21(2):258-9. PubMed ID: 8517537 [No Abstract] [Full Text] [Related]
13. Evaluation of ventilator alarms. J Med Eng Technol; 1984; 8(6):270-6. PubMed ID: 6398368 [TBL] [Abstract][Full Text] [Related]
14. Comparative bench study of triggering, pressurization, and cycling between the home ventilator VPAP II and three ICU ventilators. Tassaux D; Strasser S; Fonseca S; Dalmas E; Jolliet P Intensive Care Med; 2002 Sep; 28(9):1254-61. PubMed ID: 12209273 [TBL] [Abstract][Full Text] [Related]
15. Leak compensation in positive pressure ventilators: a lung model study. Mehta S; McCool FD; Hill NS Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129 [TBL] [Abstract][Full Text] [Related]