These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 1300111)

  • 1. A five-station hip joint simulator for wear rate studies.
    Saikko V; Paavolainen P; Kleimola M; Stätis P
    Proc Inst Mech Eng H; 1992; 206(4):195-200. PubMed ID: 1300111
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A three-axis hip joint simulator for wear and friction studies on total hip prostheses.
    Saikko VO
    Proc Inst Mech Eng H; 1996; 210(3):175-85. PubMed ID: 8885654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A hip wear simulator for the evaluation of biomaterials in hip arthroplasty components.
    Mejia LC; Brierley TJ
    Biomed Mater Eng; 1994; 4(4):259-71. PubMed ID: 7950874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A 12-station anatomic hip joint simulator.
    Saikko V
    Proc Inst Mech Eng H; 2005 Nov; 219(6):437-48. PubMed ID: 16312103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(3):233-8. PubMed ID: 10902437
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants.
    Medley JB; Krygier JJ; Bobyn JD; Chan FW; Lippincott A; Tanzer M
    Proc Inst Mech Eng H; 1997; 211(1):89-99. PubMed ID: 9141894
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant.
    Wang A
    Proc Inst Mech Eng H; 1998; 212(1):71-2; author reply 72-3. PubMed ID: 9529939
    [No Abstract]   [Full Text] [Related]  

  • 10. A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator.
    Bigsby RJ; Auger DD; Jin ZM; Dowson D; Hardaker CS; Fisher J
    J Biomech; 1998 Apr; 31(4):363-9. PubMed ID: 9672090
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A five-station hip joint simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 2001; 215(1):61-4. PubMed ID: 11323986
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Type of motion and lubricant in wear simulation of polyethylene acetabular cup.
    Saikko V; Ahlroos T
    Proc Inst Mech Eng H; 1999; 213(4):301-10. PubMed ID: 10466361
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of wear in total hip replacement using a ten station hip simulator.
    Brummitt K; Hardaker CS
    Proc Inst Mech Eng H; 1996; 210(3):187-90. PubMed ID: 8885655
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.
    Ali M; Al-Hajjar M; Partridge S; Williams S; Fisher J; Jennings LM
    Proc Inst Mech Eng H; 2016 May; 230(5):389-97. PubMed ID: 27160559
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simulator study of friction in total replacement hip joints.
    Saikko V
    Proc Inst Mech Eng H; 1992; 206(4):201-11. PubMed ID: 1300112
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A preliminary hip joint simulator study of the migration of a cemented femoral stem.
    Liu C; Green SM; Watkins ND; Gregg PJ; McCaskie AW
    Proc Inst Mech Eng H; 2003; 217(2):127-35. PubMed ID: 12666780
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.
    Zaki M; Aljinaidi A; Hamed M
    Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2005 Sep; 219(5):319-28. PubMed ID: 16225148
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A hip simulator study of metal-on-metal hip joint device using acetabular cups with different fixation surface conditions.
    Li CX; Hussain A; Kamali A
    Proc Inst Mech Eng H; 2011 Sep; 225(9):877-87. PubMed ID: 22070025
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.