These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

49 related articles for article (PubMed ID: 13109890)

  • 1. The production and repair of interatrial septal defects under direct vision with the assistance of an extracorporeal pump-oxygenator circuit.
    MILLER BJ; GIBBON JH; GRECO VF; SMITH BA; COHN CH; ALLBRITTEN FF
    J Thorac Surg; 1953 Dec; 26(6):598-616; discussion 631-2. PubMed ID: 13109890
    [No Abstract]   [Full Text] [Related]  

  • 2. Direct vision repair of intracardiac defects utilizing a rotating disc reservoir-oxygenator.
    CROSS FS; KAY EB
    Surg Gynecol Obstet; 1957 Jun; 104(6):711-6. PubMed ID: 13455375
    [No Abstract]   [Full Text] [Related]  

  • 3. The closure of interventricular septal defects in dogs during open cardiotomy with the maintenance of the cardiorespiratory functions by a pump-oxygenator.
    GIBBON JH; MILLER BJ; DOBELL AR; ENGELL HC; VOIGT GB
    J Thorac Surg; 1954 Sep; 28(3):235-40. PubMed ID: 13192868
    [No Abstract]   [Full Text] [Related]  

  • 4. [Experimental study of extracorporeal circulation under normothermia. I. The Lillehei-De Wall pump-oxygenator system].
    ENJALBERT A; ESCHAPASSE H; MATHE J; GRAULLE A
    Actual Cardiol Angeiol Int (Paris); 1961; 10():213-9. PubMed ID: 13696926
    [No Abstract]   [Full Text] [Related]  

  • 5. Successful open cardiac surgery; a mechanical pump oxygenator system.
    HERRON PW; THOMAS GI; JESSEPH JE; QUINTON WE; TREMBLAY RE; MAGUIRE RX; BRUCE RA; MERENDINO KA
    Q Rev Surg; 1957 Sep; 14(3):113-6. PubMed ID: 13466010
    [No Abstract]   [Full Text] [Related]  

  • 6. Experiences with direct-vision repair of congenital cardiovascular disorders using the rotating disc oxygenator.
    SANGER PW; TAYLOR FH; ROBISCEK F; DVORAK HJ; STAM RE
    N C Med J; 1959 Mar; 20(3):89-95. PubMed ID: 13633051
    [No Abstract]   [Full Text] [Related]  

  • 7. [Eleven open-heart operations under extracorporeal circulation; Lillehei-De Wall pump-oxygenator system].
    DUBOST C; LENFANT C; PASSELECQ J; GUERY J; WEISS M; HEIM DE; BALSAC R
    Minerva Cardioangiol Eur; 1957; 3(3):288-94. PubMed ID: 13503759
    [No Abstract]   [Full Text] [Related]  

  • 8. [Experimental researches on extracorporeal circulation with the aid of the Lillehei-Dewall oxygenator-pump; preliminary report].
    LENFANT C; WEISS M; SPROVIERI L; DUBOST C
    Minerva Med; 1957 Aug; 48(63-64):2597-602. PubMed ID: 13483253
    [No Abstract]   [Full Text] [Related]  

  • 9. [Extracorporeal circulation with the Gibbon-Mayo-pump oxygenator at the Chirurgische Klinik Duesseldorf].
    FERBERS E
    Zentralbl Chir; 1961 Apr; 86():1154-6. PubMed ID: 13698858
    [No Abstract]   [Full Text] [Related]  

  • 10. Studies in extracorporeal circulation. V. Anesthesia and supportive care during intracardiac surgery with the Gibbon-type pump-oxygenator.
    PATRICK RT; THEYE RA; MOFFITT EA
    Anesthesiology; 1957; 18(5):673-85. PubMed ID: 13458862
    [No Abstract]   [Full Text] [Related]  

  • 11. Correction of congenital cardiac defects utilizing the pump oxygenator.
    CAMPBELL GS; CAYLER GG; RICHARDSON WR; SNYDER DD; WILLIAMS GR
    J Okla State Med Assoc; 1959 Apr; 52(4):221-7. PubMed ID: 13642161
    [No Abstract]   [Full Text] [Related]  

  • 12. The artificial heart-lung apparatus, experimental creation and repair of interventricular septal defects.
    DENNIS C; GORAYEB EJ; ITICOVICI HN; KERNAN M; LEVOWITZ BS; NEWMAN MM; STUCKEY JH; YOUNG LA
    Surg Forum; 1956; 6():185-9. PubMed ID: 13391448
    [No Abstract]   [Full Text] [Related]  

  • 13. Hemodynamic energy delivery of the pulsatile flow in a simulated pediatric extracorporeal circuit.
    Wang S; Haines N; Undar A
    ASAIO J; 2009; 55(1):96-9. PubMed ID: 19092666
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Interventricular communication with infundibular stenosis and predominant left-right shunt. Complete correction under extracorporeal circulation with induced cardiac arrest].
    DELANNOY E
    Lille Med; 1961 Jan; 6():18-25. PubMed ID: 13721447
    [No Abstract]   [Full Text] [Related]  

  • 15. Cardiac operations with extracorporeal circulation.
    KAY JH; ANDERSON RM; LEWIS RR; MEIHAUS J; MAGIDSON O; SNYDER EN; BENNETT LC; BERNSTEIN S; AMSDEN N
    Calif Med; 1959 Jul; 91(1):6-7. PubMed ID: 13662856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Production and repair of experimental interventricular septal defects under direct vision with the aid of hypothermia.
    TAUFIC M; LEWIS FJ
    Surg Forum; 1953 Oct; 4():67-72. PubMed ID: 13187241
    [No Abstract]   [Full Text] [Related]  

  • 17. [The effects of open heart surgery under hypothermia and extracorporeal circulation with oxygenator on the blood plasma level of 17-hydroxycorticosteroids and on the urinary excretion of 17-ketosteroids].
    ICHIKAWA H
    Kyobu Geka; 1961 Sep; 14():746-54. PubMed ID: 13717368
    [No Abstract]   [Full Text] [Related]  

  • 18. [Arrested coronary artery bypass grafting with modified percutaneous cardiopulmonary support circuit (mini-pump system)].
    Takai H; Eishi K
    Kyobu Geka; 2006 Jul; 59(8 Suppl):625-30. PubMed ID: 16910505
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A discussion of an oxygenator-pump used in total by-pass of the heart and lungs in dogs.
    HELMSWORTH JA; CLARK LC; KAPLAN S; SHERMAN RT; LARGEN T
    Surg Forum; 1953; (38th Congress):158-65. PubMed ID: 13122427
    [No Abstract]   [Full Text] [Related]  

  • 20. A simple cardiac pump and oxygenator for open-heart surgery.
    GREEN E; GILFILLAN RS; COHN R
    Stanford Med Bull; 1957 Nov; 15(4):320-2. PubMed ID: 13495746
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.